Honeywell 3800 Linear Series Скачать руководство пользователя страница 1

™ 

3800/3900

Handheld Linear Imager

User’s Guide

Содержание 3800 Linear Series

Страница 1: ... 3800 3900 Handheld Linear Imager User s Guide ...

Страница 2: ... omissions con tained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied repro duced or translated into another language without the prior written consent of Honeywell 2000 2008 Honeywell ...

Страница 3: ...one or more of the fol lowing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help If necessary the user should consult the dealer or an experienced radio telev...

Страница 4: ... 9 13 5627 BT Eindhoven The Netherlands Honeywell shall not be liable for use of our product with equipment i e power supplies personal computers etc that is not CE marked and does not comply with the Low Voltage Directive LED Safety Statement This device has been tested in accordance with IEC60825 1 1993 A1 A2 LED safety and has been certified to be a Class 1 LED device For European Community Use...

Страница 5: ...te separate take back systems for product disposal If you need more information on the collection reuse and recycling systems please contact your local or regional waste administration You may also contact your supplier for more information on the environmental performances of this product UL and cUL Statement UL and cUL listed UL60950 1 and CSA C22 2 No 60950 1 03 C Tick Statement Conforms to AS ...

Страница 6: ......

Страница 7: ...nterface 1 10 NCR OCIA Short Format 8 Bit Interface 1 11 NCR OCIA Long Format 9 Bit Interface 1 11 Nixdorf OCIA Interface 1 12 Serial Wedge 1 12 Chapter 2 Terminal Interfaces Keyboard Wedge Connection 2 1 Terminal ID 2 1 Supported Terminals 2 2 Keyboard Country 2 4 Keyboard Style 2 4 Keyboard Modifiers 2 5 Serial Port Connection 2 7 Baud Rate 2 8 RS 232 Word Length Data Bits Stop Bits and Parity 2...

Страница 8: ...ta Editing Prefix Suffix Overview 4 1 To Add a Prefix or Suffix 4 1 To Clear One or All Prefixes or Suffixes 4 2 To Add a Carriage Return Suffix to all Symbologies 4 3 Prefix Selections 4 3 Suffix Selections 4 3 Symbology Chart 4 4 ASCII Conversion Chart Code Page 1252 4 5 Function Code Transmit 4 6 Intercharacter Interfunction and Intermessage Delays 4 6 Intercharacter Delay 4 7 User Specified In...

Страница 9: ...on 6 1 Secondary RS 232 Connection 6 1 Secondary Non Decoded Output Laser Emulation 6 2 Non Decoded Output Laser Emulation Transmission Rate 6 2 Non Decoded Output Laser Emulation Polarity 6 2 Non Decoded Laser Emulation Idle 6 3 Disabling the Secondary Interface 6 3 Secondary Trigger Mode 6 3 Chapter 7 Symbologies Introduction 7 1 All Symbologies 7 1 Message Length Description 7 2 Codabar 7 3 Sta...

Страница 10: ...of 5 Industrial 7 13 Straight 2 of 5 Industrial Message Length 7 13 Straight 2 of 5 IATA 7 14 Straight 2 of 5 IATA Message Length 7 14 Matrix 2 of 5 7 15 Matrix 2 of 5 Message Length 7 15 Code 11 7 16 Check Digits Required 7 16 Code 11 Message Length 7 17 Code 128 7 18 GS Substitution 7 18 Code 128 Message Length 7 19 Telepen 7 20 Telepen Output 7 20 Telepen Message Length 7 21 UPC A 7 22 Check Di...

Страница 11: ...ddenda 7 32 Addenda Required 7 32 Addenda Separator 7 32 MSI 7 33 Check Character 7 33 MSI Message Length 7 34 Plessey 7 35 Plessey Message Length 7 35 GS1 DataBar 7 36 GS1 DataBar Limited 7 36 GS1 DataBar Expanded 7 37 GS1 DataBar Expanded Message Length 7 37 China Post Code 7 38 China Post Message Length 7 38 PDF417 7 39 PDF417 Message Length 7 39 Show GLI Blocks 7 40 Scan Diagnostics 7 40 PDF L...

Страница 12: ... Firmware 9 2 Chapter 10 Interface Keys Keyboard Function Relationships 10 1 Supported Interface Keys 10 3 Chapter 11 Utilities To Add a Test Code I D Prefix to All Symbologies 11 1 Show Software Revision 11 1 Show Data Format 11 1 Specular Effect Reduction 11 2 Chapter 12 Serial Programming Commands Conventions 12 1 Menu Command Syntax 12 1 Query Commands 12 2 Concatenation of Multiple Commands 1...

Страница 13: ...ble Pinouts 13 3 Chapter 14 Maintenance Repairs 14 1 Maintenance 14 1 Replacing the Interface Cable 14 1 Troubleshooting 14 2 Chapter 15 Customer Support Technical Assistance 15 1 Online Technical Assistance 15 1 Product Service and Repair 15 2 Online Product Service and Repair Assistance 15 2 Limited Warranty 15 2 ...

Страница 14: ...viii ...

Страница 15: ...l Applications for the 3900 The 3900 is an ideal scanner for retail kiosks The bright aiming line and large working range make scanning easy for untrained users The 3900 mounted in a stand makes an efficient barcode document reader it takes up a minimum of counter space and reads and transmits data quickly About This Manual This User s Guide provides installation and programming instructions for t...

Страница 16: ... or Pate ntdeta il s Made i n US A gepr uf te S i cherhe it TUV Rheinland Product Safety E 15374 0 7D21 Tes t ed toC omplyWithFCC Sta ndar ds FOR HOME OR OFFICE USE Cetappare i lnumeriq u edela Classe B est conforme ala normeNMB 003duCanada Thi sClas sB digita l appara tus complies with Canadia n I CES 003 N10410 Hand Held Products Inc ww w handhe ld com Compliance Label location Item Number Seria...

Страница 17: ...llowing is an example of a keyboard wedge connection 1 Turn off power to the terminal computer 2 Disconnect the keyboard cable from the back of the terminal computer 3 Connect the appropriate interface cable to the scanner and to the terminal computer 4 Turn the terminal computer power back on The scanner beeps twice 5 Verify the scanner operation by scanning a barcode from the Sample Symbols in t...

Страница 18: ...aperture plane 2 Ref typ 4 64 2 67 1 52 Ref 2 99 47 5 89 04 700 700 M4 Inserts typ 3 Thread depth 4 7 mm 185 Cable Exit 1 3 65 2 5 13 mil and 15 mil 3 5 5 mil and 7 5 mil 4 1 5 6 7 8 5 9 5 3 mil 5 mil 7 5 mil 13 mil 15 mil 23 typ 4 9 4 2 3 1 9 T YPICAL PERFORMANCE ON HIGH QUALITY SYMBOLS Note Measurements are in inches ...

Страница 19: ...edge turn to page 2 1 If the scanner is connected via a serial port turn to page 2 7 If this is a wand emulation application turn to page 2 13 and for a non decoded output connection turn to page 6 2 Plug and Play Plug and Play barcodes provide instant scanner set up for commonly used inter faces Note After you scan one of the codes power cycle the host terminal to have the interface in effect The...

Страница 20: ...r second and the polarity to white high For most laptops scanning the Laptop Direct Connect barcode allows opera tion of the integral keyboard The following Laptop Direct Connect barcode also programs a carriage return CR suffix The RS 232 Interface barcode is used when connecting to the serial port of a PC or terminal The following RS 232 Interface barcode adds a suffix of a CR and LF and also pr...

Страница 21: ...mbology It also programs the Transmission Rate to 25 inches per second and Output Polarity to black high Note For the 3800PDF model When the 3800PDF interface is set to wand emulation all PDF417 barcode data is transmitted as Code 128 Data from other symbologies follow the rules described above IBM 4683 Ports 5B 9B and 17 Interface Note The following Retail Plug and Play codes are for use with the...

Страница 22: ...logy USB Interface Note The following USB Plug and Play codes IBM SurePOS handheld and tabletop scanners are for use with the 3800XX 15 models only A scanner can be connected to the USB port of a computer Symbology Suffix EAN 8 0C EAN 13 16 UPC A 0D UPC E 0A Code 39 00 0A 0B Interleaved 2 of 5 00 0D 0B Code 128 00 18 0B IBM 4683 Port 5B Interface IBM 4683 Port 9B HHBCR 1 Interface IBM 4683 Port 9B...

Страница 23: ... USB programming and technical information refer to USB Appli cation Note available at www honeywell com aidc Scan one of the following Plug and Play codes to program the 3800 for IBM SurePos USB Handheld scanner or IBM SurePos USB Tabletop scanner Note After scanning one of these codes you must re boot the cash register Each barcode above also programs the following suffixes for each symbology Sy...

Страница 24: ...nterfaces are only available on the 3800XX 11 and 3800XX 11E models Scan one of the following Plug and Play codes to program the 3800 for Generic OCIA NCR OCIA Short Format 8 bit NCR OCIA Long Format 9 bit and Nixdorf OCIA Note After scanning one of these codes you must re boot the cash register EAN 13 16 UPC A 0D UPC E 0A Code 39 00 0A 0B Interleaved 2 of 5 00 0D 0B Code 128 00 18 0B Symbology Su...

Страница 25: ... each symbology NCR OCIA Long Format 9 Bit Interface The NCR OCIA Long Format 9 Bit barcode also programs the following pre fixes for each symbology Symbology Prefix EAN 8 06 06 EAN 13 06 UPC A 01 UPC E 05 Symbology Prefix EAN 8 0F 0F EAN 13 0F UPC A 0A UPC E 0E Symbology Prefix EAN 8 46 46 EAN 13 46 UPC A 41 UPC E 45 Code 39 42 31 NCR OCIA Short Format 8 Bit Interface NCR OCIA Long Format 9 Bit I...

Страница 26: ...and communications protocol To set up the serial wedge terminal ID find the terminal ID in the Supported Ter minal Chart and follow the instructions on page 2 1 Set the port to which you want the scanned data to transmit Port 1 corresponds to P1 on the output cable and Port 2 corresponds to P2 on the output cable Choosing Both sends scanned data to P1 and P2 Default P1 Interleaved 2 of 5 42 32 Cod...

Страница 27: ...1 13 P1 P2 Both P1 and P2 ...

Страница 28: ...1 14 ...

Страница 29: ...on page 2 2 through page 2 3 and locate the Terminal ID number for your PC Scan the Terminal ID barcode below then scan the numeric barcode s on the inside back cover of this manual to program the scanner for your terminal ID Scan Save to save your selection For example an IBM AT terminal has a Terminal ID of 003 You would scan the Terminal ID barcode then 0 0 3 from the inside back cover then Sav...

Страница 30: ...91 3192 3194 3196 3197 3471 3472 3476 3477 006 IBM 122 key 3191 3192 3471 3472 007 IBM 122 key 3196 3197 3476 3477 3486 3482 3488 008 IBM 122 key 3180 024 IBM 122 key 3180 data entry keyboard 114 IBM DOS V 106 key PC Workstation 102 IBM SurePOS USB Handheld Scanner 128 IBM SurePOS USB Tabletop Scanner 129 IBM Thinkpad 360 CSE 340 750 097 IBM Thinkpad 106 IBM Thinkpad 365 755CV 003 I O 122 key 2676...

Страница 31: ...rter 124 USB PC Keyboard 124 USB Mac Keyboard 125 Wand Emulation 061 Default for 11 12 models Applies to 12 models only Default for 13 model applies to 13 models only Applies to 15 model only Because special suffixes are required by the IBM SurePOS terminal it is best to use the Plug and Play barcodes on page 1 9 to program these interfaces rather than scanning the terminal ID listed in this table...

Страница 32: ...or countries other than the United States Keyboard Style This programs keyboard styles such as Caps Lock and Shift Lock Default Regular Regular is used when you normally have the Caps Lock key off Caps Lock is used when you normally have the Caps Lock key on Country Code Scan Country Code Scan Belgium 1 Italy 5 Denmark 8 Norway 9 Finland 2 Spain 10 France 3 Switzerland 6 Germany Austria 4 USA Defa...

Страница 33: ...rd IBM AT or equivalent To connect the scanner to a laptop it may be necessary to use the Automatic Direct Connect selection on page 2 6 in con junction with the barcode below Note After scanning the Emulate External Keyboard barcode you must power cycle your computer Keyboard Modifiers This modifies special keyboard features such as CTRL ASCII codes and Turbo Mode Control ASCII Mode On The scanne...

Страница 34: ...d from a numeric keypad Default Off Automatic Direct Connect Use this selection if you are using a laptop whose keyboard is disabled when you plug in the scanner This selection can also be used if you have an IBM AT style terminal and the system is dropping charac ters Default Off Turbo Mode On Turbo Mode Off Numeric Keypad Mode On Numeric Keypad Mode Off Automatic Direct Connect Mode On Automatic...

Страница 35: ...ta and adds a suffix of a CR LF 1 Turn off power to the terminal computer 2 Connect the appropriate interface cable to the scanner Note For the scanner to work properly you must have the correct cable for your type of terminal computer 3 Plug the serial connector into the serial port on the back of your computer terminal Tighten the two screws to secure the connector to the port 4 Plug the power p...

Страница 36: ...ts Stop Bits and Parity Data Bits sets the word length at 7 or 8 bits of data per character If an applica tion requires only ASCII Hex characters 0 through 7F decimal text digits and punctuation select 7 data bits For applications which require use of the full ASCII set select 8 data bits per character Default 7 Stop Bits sets the stop bits at 1 or 2 Default 1 300 2400 600 1200 4800 38400 9600 192...

Страница 37: ...ns for validity Default Even 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity Mark 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 1 Stop Parity Space 7 Data 2 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 7 Data 2 Stop Parity Mark ...

Страница 38: ...2 Word Length Data Bits Stop Bits and Parity continued 8 Data 1 Stop Parity None 7 Data 2 Stop Parity Space 8 Data 1 Stop Parity Even 8 Data 1 Stop Parity Odd 8 Data 1 Stop Parity Mark 8 Data 1 Stop Parity Space ...

Страница 39: ...TS CTS XON XOFF and ACK NAK Off Wand Emulation Connection In Wand Emulation mode the scanner decodes the barcode then sends data in the same format as a wand scanner The Code 39 Format converts all symbol ogies to Code 39 The Same Code Format transmits UPC EAN Code 128 and RTS CTS On XON OFF Off RTS CTS Off XON XOFF On ACK NAK On ACK NAK Off ...

Страница 40: ...mat Note For the 3800PDF model When the 3800PDF interface is set to wand emulation all PDF417 barcode data is transmitted as Code 128 Data from other symbologies follow the rules described above Wand Emulation Transmission Rate The Transmission Rate is limited by the terminal s ability to receive data without dropping characters Default 25 inches second Code 39 Format Same Code Format 10 80 25 40 ...

Страница 41: ...e state of the scanner when no data is being transmitted When in Wand Emulation mode you must set the scanner s idle state to match the idle state for the device to which the scanner is connected Default Idle High PDF417 Wand Emulation Note The following Wand Emulation functions are for use with the 3800PDF 12 and 3800PDF 12E scanners only Black High White High Idle High Idle Low ...

Страница 42: ... Block Size This transmits the PDF417 data in smaller blocks to prevent buffer overflow Default 60 Delay Between Blocks This sets the delay time between data blocks Default 50ms 20 80 40 60 5ms 500ms 50ms 150ms ...

Страница 43: ... is turned on a computed check character is added at the end of the entire message The check character is the character which when Exclu sive OR d with every preceding character of the message yields a result of 0x00 00H Default Off On Off ...

Страница 44: ...2 16 ...

Страница 45: ...nt remains the same Scan speeds are 270 s s 135 s s and 67 s s A scan speed of 270 draws the highest power and has the best performance A scan speed of 135 has a medium draw with medium performance A scan speed of 67 draws the lowest power and has the lowest performance Default 270 s s Beeper Volume Default High 270 s s 135 s s 67 s s High Medium Off Low ...

Страница 46: ... in the Default Charts beginning on page 12 5 High doubles the votes used below the threshold Default Voting Normal Reduce Quiet Zone Reducing the quiet zone requirements below AIM guidelines makes it possible to read off spec barcodes This feature is effective with all symbologies Default Don t Reduce Quite Zone Normal Beep Short Beep Voting Normal Voting High Don t Reduce Quiet Zone Reduce Quiet...

Страница 47: ...rotects against accidental rereads of the same barcode Longer delays are effective in minimizing accidental rereads at POS point of sale Use shorter delays in applications where repetitive bar code scanning is required Default Short Reread Delay only works when in automatic trigger mode see page 3 4 Short Medium Long Extra Long ...

Страница 48: ...is released When in serial mode the scanner scans until a barcode has been read or until the deactivate command is sent In serial mode the scanner can also be set to turn itself off after a specified time has elapsed see Serial Trigger Time Out which follows Default for 3800 Serial Trigger Time Out Use this selection to set a time out in quarter sec onds of the scanner s trigger when using serial ...

Страница 49: ...on when the scanner is first triggered but there is no delay when operating in low power mode Note Manual Trigger Low Power cannot be used with keyboard wedge applications Low Power Time Out Scan the Low Power Time Out barcode to change the time out duration Then scan the time out duration from 0 300 seconds from the inside back cover and Save Default 2 minutes Note If you make an error while scan...

Страница 50: ...tically to read the code Presentation Mode uses normal office or store ambient light to detect the barcodes Note Do not use Presentation Mode with a 3800 3900PDF Normal office or store ambient light does not provide enough illumination for the 3800 3900PDF to work properly in Presentation Mode Presentation Mode ...

Страница 51: ...this chapter are only used if you wish to alter the default settings Default prefix None Default suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII chart page 4 5 plus Code I D and Aim I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in w...

Страница 52: ...rogramming Chart inside back cover Step 4 Determine the hex value from the Decimal to Hex to ASCII Conversion Chart page 4 5 for the CR carriage return Step 5 Scan 0 D from the Programming Chart inside back cover Step 6 Scan Save or scan Discard to exit without saving To Clear One or All Prefixes or Suffixes You can clear a single prefix or suffix or clear all prefixes suffixes for a symbol ogy Wh...

Страница 53: ...turn Suffix to all symbologies at once This action first clears all current suffixes then programs a carriage return suffix for all symbologies Prefix Selections Suffix Selections Add CR Suffix All Symbologies Add Prefix Clear One Prefix Clear All Prefixes Add Suffix Clear One Suffix Clear All Suffixes Save Discard ...

Страница 54: ...atrix 2 of 5 m X0 6D Codabar a F0 61 MicroPDF417 R L0 52 Code 11 h H0 68 MSI g M0 67 Code 32 Pharmaceutical PARAF w X0 77 PDF417 r L0 72 Code 39 b A0 62 Plessey Code n P0 6E Code 93 i G0 69 Straight 2 of 5 IATA f R0 66 Code 128 j C0 6A Straight 2 of 5 Industrial f S0 66 EAN JAN d E0 64 Telepen t B0 74 EAN UCC Composite y e0 79 UPC c E0 63 GS1 DataBar y e0 79 Interleaved 2 of 5 e l0 65 All Symbolog...

Страница 55: ...105 69 i 10 0A LF 42 2A 74 4A J 106 6A j 11 0B VT 43 2B 75 4B K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n 15 0F SI 47 2F 79 4F O 111 6F o 16 10 DLE 48 30 0 80 50 P 112 70 p 17 11 DC1 49 31 1 81 51 Q 113 71 q 18 12 DC2 50 32 2 82 52 R 114 72 r 19 13 DC3 51 33 3 83 53 S 115 73 s 20 14 DC4 52 34 4 84 54 T 116 74 t 21 15 NAK 53 35 5 85 55 ...

Страница 56: ...he scanner is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characters if data comes through too quickly Intercharacter interfunction and intermessage delays slow the transmission of data increasing data integrity Each delay is composed of a 5 millisecond s...

Страница 57: ...tercharacter Delay This is a delay of up to 495 milliseconds in multiples of 5 placed after the transmission of a particular character of scanned data You can program up to 99 steps of 5 ms each to follow the character you specify Scan the Delay Length barcode below then the number of steps for the delay and the SAVE barcode from the inside back cover Next scan the Character to Trigger Delay barco...

Страница 58: ...on Delay barcode then set the number of steps to 00 Scan the SAVE barcode from the inside back cover Intermessage Delay This is a delay of up to 495 milliseconds in multiples of 5 placed between each scan transmission You can program up to 99 steps of 5 ms each Scan the Intermessage Delay barcode below then scan the number of steps and the SAVE barcode from the inside back cover Note If you make a...

Страница 59: ... Code ID Universal Length 5 Universal Term ID Actual Code ID Actual Length 6 Universal Term ID Actual Code ID Universal Length 7 Universal Term ID Universal Code ID Actual Length 8 Universal Term ID Universal Code ID Universal Length If you have changed data format settings and wish to clear all formats and return to the defaults scan the Default Data Format code on page 5 4 To Add a Data Format S...

Страница 60: ...data format for that symbology is deleted and all other formats are unaffected Save This exits saving any Data Format changes Discard This exits without saving any Data Format changes Data Format Editor Commands Send Commands F1 Send all characters followed by xx key or function code starting from cur rent cursor position Syntax F1xx xx stands for the hex value for an ASCII code see Decimal to Hex...

Страница 61: ...osi tion leaving cursor pointing to non xx character Syntax E6xx xx stands for the hex value for an ASCII code see Decimal to Hex to ASCII Conversion chart page 4 5 E7 Search back for the first non xx character from the current cursor position leaving cursor pointing to non xx character Syntax E7xx xx stands for the hex value for an ASCII code see Decimal to Hex to ASCII Conversion chart page 4 5 ...

Страница 62: ...Hex to ASCII Conversion chart page 4 5 EC Check to make sure there is an ASCII number at the current cursor posi tion If character is not numeric format is aborted Syntax EC ED Check to make sure there is a non numeric ASCII character at the current cursor position If character is numeric format is aborted Syntax ED Data Format Editor Enter Data Format Default Data Format Clear One Data Format Sav...

Страница 63: ...y to scan one barcode using a different data format than your primary format When data formats are pro grammed see page 5 1 you must input whether you are programming the pri mary format or an alternate format numbered 1 2 or 3 An alternate format is initiated by scanning one of the 3 alternate format bar codes below The scanner will scan the next barcode formatting the data with the selected alte...

Страница 64: ...5 6 ...

Страница 65: ...rts all other symbologies to Code 39 These codes set the transmission rate to 25 inches per second and the output polarity to black high Default Code 39 Format Note for the 3800PDF model When the 3800PDF interface is set to wand emulation all PDF417 barcode data is transmitted as Code 128 Data from other symbologies follow the rules described above Secondary RS 232 Connection All communication par...

Страница 66: ...lar ity to white high Non Decoded Output Laser Emulation Transmission Rate The Transmission Rate is limited by the terminal s ability to receive data without dropping characters Default 36 scans second Non Decoded Output Laser Emulation Polarity The Polarity can be sent as standard with white bars high or reversed with black bars high Default White High Non Decoded Output 36 100 White High Black H...

Страница 67: ...h Disabling the Secondary Interface You can temporarily disable the secondary interface but still retain the second ary interface settings in the scanner s memory by scanning the Disable barcode below To re enable the secondary interface scan the Enable barcode Default Disable Secondary Trigger Mode Manual Trigger You must press the scanner trigger to scan When not scan ning idle power is maintain...

Страница 68: ...me Out Scan the Low Power Time Out barcode to change the time out duration Then scan the time out duration from 0 300 seconds from the inside back cover and Save Default 2 minutes Note If you make an error while scanning the digits before scanning Save scan Discard on the back cover scan the Low Power Time Out barcode scan the correct digits and Save again Note The Secondary Manual Trigger Lower P...

Страница 69: ...f you want to decode all the symbologies allowable for your scanner scan the All Symbologies On code All Symbologies Interleaved 2 of 5 China Post Code Matrix 2 of 5 Codabar MicroPDF417 Code 11 MSI Code 32 Pharmaceutical PARAF PDF417 Code 39 Plessey Code 93 Straight 2 of 5 IATA Code 128 Straight 2 of 5 Industrial EAN JAN 13 Telepen EAN UCC Composite UPC A GS1 DataBar All Symbologies On All Symbolo...

Страница 70: ...the chances of a misread EXAMPLE Decode only those barcodes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those barcodes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message length defaults scan the barcodes included in the explanation of the symbology then scan the digit value of the message length and S...

Страница 71: ...ted using different modulos You can pro gram the scanner to read only Codabar barcodes with Modulo 16 check charac ters Default No Check Character No Check Character indicates that the scanner reads and transmits barcode data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar barcodes printed with a check character and will tra...

Страница 72: ...u Enable concatenation the scanner looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Default On Select Require to prevent the scanner from decoding a lone Codabar symbol No Check Character Validate Modulo 16 and Transmit Validate Modulo 16 but Don t Transmit A12D...

Страница 73: ...he barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Minimum Message Length Maximum Message Length ...

Страница 74: ... Stop characters Default Don t Transmit Check Character No Check Character indicates that the scanner reads and transmits barcode data with or without a check character When Check Character is set to Validate but Don t Transmit the unit will only read Code 39 barcodes printed with a check character but will not transmit the check character with the scanned data On Off Transmit Don t Transmit ...

Страница 75: ...imum and Maximum lengths 0 48 Minimum Default 0 Maximum Default 48 Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer When this func tion is enabled the scanner stores those Code 39 barcodes that start with a space excluding the start and stop symbols and does not immediately trans mit the data Th...

Страница 76: ...ner transmits the appended data when it reads a Code 39 barcode that starts with a character other than a space Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical PARAF is a form of the Code 39 symbology used by Italian pharmacies Off On Off On ...

Страница 77: ...h Y decode as 0 through 9 NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS H CAN X H 8 8 H H X X h H x X HT I EM Y I 9 9 I I Y Y i I y Y LF J SUB Z J Z J J Z Z j J z Z VT ...

Страница 78: ... Don t Transmit the unit will only read Interleaved 2 of 5 barcodes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner will only read Interleaved 2 of 5 barcodes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit On Off Validate but Don t Trans...

Страница 79: ...tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Strict Decoding When Strict Decoding is used the scanner only reads barcodes that are close to spec This reduces the number of misreads but also reduces the tolerance for barcodes that are slightly out of spec Minimum Message Length Maximum Message Length Off On ...

Страница 80: ...age Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Страница 81: ...strial Straight 2 of 5 Industrial Message Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Страница 82: ... Straight 2 of 5 IATA Message Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Страница 83: ... 2 of 5 Message Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Страница 84: ...e 11 Default All Code 11 Settings Code 11 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes Default Two Check Digits On Off One Check Digit Two Check Digits ...

Страница 85: ...n the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Страница 86: ...7 18 Code 128 Default All Code 128 Settings Code 128 GS Substitution When enabled the scanner substitutes a GS for Function Character 1 when decoding EAN 128 Default Off On Off Off On ...

Страница 87: ...an the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Страница 88: ...top pattern 1 and decodes them as standard full ASCII start stop pattern 1 When Original Telepen Output is selected the scanner reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output On Off Original Telepen Output AIM Telepen Output ...

Страница 89: ...n the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 Minimum Message Length Maximum Message Length ...

Страница 90: ...you to specify whether the check digit should be transmit ted at the end of the scanned data or not Default On Number System The numeric system digit of a UPC symbol is normally transmitted but the unit can be programmed so it will not transmit it Default On On Off On Off Off On ...

Страница 91: ... data Default Off for both 2 Digit and 5 Digit Addenda Addenda Required When Addenda Required is set to on the scanner will only read UPC A bar codes that have addenda Default Off 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Страница 92: ...the data from the addenda When turned off there is no space Default On UPC Strict Decoding When UPC Strict Decoding is used the scanner only reads barcodes that are close to spec This reduces the number of misreads but also reduces the toler ance for barcodes that are slightly out of spec Off On Off On ...

Страница 93: ...em For these codes use the UPC E0 selection If you need to read codes that lead with the 1 number sys tem use the UPC E1 selection Default On UPC E0 and Off UPC E1 UPC E Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 On UPC E0 Off UPC E1 On UPC E1 Off Off On ...

Страница 94: ...e numeric system digit of a UPC symbol is normally transmitted but the unit can be programmed so it will not transmit it Default On Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda Off On Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Страница 95: ...canner will only read UPC E bar codes that have addenda Default Off Addenda Separator When this feature is on there is a space between the data from the barcode and the data from the addenda When turned off there is no space Default On Not Required Required Off On ...

Страница 96: ...AN JAN 13 Default All EAN JAN Settings EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmit ted at the end of the scanned data or not Default On On Off Off On ...

Страница 97: ...3 data Default Off for both 2 Digit and 5 Digit Addenda Addenda Required When Addenda Required is set to on the scanner will only read EAN JAN 13 barcodes that have addenda Default Off 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Страница 98: ...ature is on there is a space between the data from the barcode and the data from the addenda When turned off there is no space Default On ISBN Enable This symbology allows the scanner to read ISBN codes on books Default Off Off On Off On ...

Страница 99: ...AN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmit ted at the end of the scanned data or not Default On On Off Off On ...

Страница 100: ...quired is set to on the scanner will only read EAN JAN 8 barcodes that have addenda Default Off Addenda Separator When this feature is on there is a space between the data from the barcode and the data from the addenda When turned off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required Off On ...

Страница 101: ...the scanner to read only MSI barcodes with Type 10 or Type 11 check characters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate and Transmit the scanner will only read MSI barcodes printed with the specified type check character and will transmit this character at the end of the scanned data On Off ...

Страница 102: ...ned data MSI Message Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 10 and Transmit Validate Type 10 but Don t Transmit Validate Type 11 but Don t Transmit Validate Type 11 and Transmit Minimum Message Length Maximum Message L...

Страница 103: ...age Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Страница 104: ...ings GS1 DataBar GS1 DataBar is a family of linear barcodes that meets restricted space require ments while still providing full product identification GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off ...

Страница 105: ... GS1 DataBar Expanded Message Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 On Off Minimum Message Length Maximum Message Length ...

Страница 106: ...hina Post Message Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Страница 107: ... Default All PDF417 Settings PDF417 PDF417 Message Length Note Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 On Off Minimum Message Length Maximum Message Length ...

Страница 108: ...he scanned code When Scan Diagnostics is turned on the scanner sends PDF417 symbology information as codes are scanned Your terminal displays the data from the scanned code first then the diagnostic infor mation Default Off The following list shows the information that appears for the PDF417 symbol ogy Note The higher the percentage of unused error correction UEC the easier it should be to read ea...

Страница 109: ... are more compact than others the reading distance varies from code to code When you turn on the PDF Learn Mode the 3800 3900 s light becomes very bright when you are at the best distance for reading the PDF417 code Default Off MicroPDF417 Note The following selections are for use with the 3800 3900PDF 12 and 3800 3900PDF 12E scanners only Default All MicroPDF417 Settings MicroPDF417 On Off On Off...

Страница 110: ...posite Symbology Note The following selections are for use with the 3800 3900PDF 12 and 3800 3900PDF 12E scanners only Default All EAN UCC Composite Symbology Settings EAN UCC Composite Linear codes are combined with a unique 2D composite component to form a new class called EAN UCC Composite Symbology EAN UCC Composite Symbology allows for the co existence of symbologies already in use Minimum Me...

Страница 111: ... primary component EAN UCC Composite Code Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 2435 Minimum Default 1 Maximum Default 2435 On Off Minimum Message Length Maximum Message Length ...

Страница 112: ...7 44 ...

Страница 113: ...oftware to the remaining 10 pin modular connector on the cloning cable 4 Connect the power supply to the 4 pin mini DIN connector located on the cloning cable or the scanner cable 5 Make sure both units are on and then scan the Clone Destination barcode with the destination scanner 6 Scan the Clone Source barcode below with the source scanner The scanner s Good Read LED begins blinking periodicall...

Страница 114: ...8 2 ...

Страница 115: ...munication port and an RS 232 cable to connect the port to the device A power supply which plugs into the cable is also required Visual Menu Operations The Visual Menu program performs the following operations Displays all configuration data and saves the information to a file on your PC Configures the device to meet your specific requirements Visual Menu has all the programming parameters which a...

Страница 116: ...rompts to install the Visual Menu program 9 If you ve selected the defaults during installation you can click on Start All Programs Visual Menu Note If you wish you can create a shortcut to the Visual Menu executable on your desktop Upgrading USB Firmware After you use Visual Menu to upgrade your scanner s firmware you need to scan the following barcode to upgrade the USB firmware You must have th...

Страница 117: ...terminals that can be used with the scanner Function Code HEX ASCII Value Full ASCII CTRL NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E 6 US 1F ...

Страница 118: ...pply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ...

Страница 119: ...ved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E Insert Insert Insert SI 0F Escape Escape F19 DLE 10 F11 Reserved Error Reset DC1 11 Home Home Home DC2 12 Print Print F20 DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Backfield Back Tab NAK 15 F12 Reserved F2...

Страница 120: ...0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Print Print DC3 13 Back Space Back Space DC4 14 Back Tab Back Field NAK 15 F19 Reserved SYN 16 F1 PF1 ETB 17 F2 PF2 CAN 18 F3 PF3 EM 19 F4 PF4 SUB 1A F5 PF5 ESC 1B F6 PF6 FS 1C F7 PF7 GS 1D F8 PF8 RS 1E F9 PF9 US 1F F10 Ho...

Страница 121: ...e New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escape Escape Escape DLE 10 F11 F11 F11 DC1 11 Insert Insert Home DC2 12 F13 F13 Print DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Back Tab NAK 15 F12 F12 F12 SYN 16 F1 F1 F1 ETB 17 F2 F2 F2 CAN 18 F3 F3 F3 EM 19 F4...

Страница 122: ...ak ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Prnt Scrn DC3 13 BACKSPACE DC4 14 LSHIFT TAB NAK 15 F12 SYN 16 F1 ETB 17 F2 CAN 18 F3 EM 19 F4 SUB 1A F5 ESC 1B F6 FS 1C F7 GS 1D F8 RS 1E F9 US 1F F10 DEL 7F BACKSPACE ...

Страница 123: ...tifies each symbology This action first clears all cur rent prefixes then programs a Code I D prefix for all symbologies This is a temporary setting that will be removed when the unit is power cycled Show Software Revision Scan the barcode below to output the current software revision Show Data Format Scan the barcode below to show current data format settings Add Code I D Prefix to All Symbologie...

Страница 124: ...ct Reduction When the On code is scanned the first pass read rate and voting threshold are increased Default Off Note If you want to further limit specular effects reduce the scan speed using Scan Rate on page 3 1 On Off ...

Страница 125: ...u commands have the following syntax spaces have been used for clarity only Prefix Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Tag A 3 character case insensitive field that identifies the desired menu command group For example all RS 232 configuration settings are identified with a Tag of 232 SubTag A 3 character case insensitive field ...

Страница 126: ...the query applies only to the specific command identified by the Tag and SubTag fields Concatenation of Multiple Commands Multiple commands can be issued within one Prefix Storage sequence Only the Tag SubTag and Data fields must be repeated for each command in the sequence If additional commands are to be applied to the same Tag then the new command sequence is separated with a comma and only the...

Страница 127: ...ple 3 What is the device s current setting for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indicates that the device s Codabar Coding Enable CBRENA is set to 1 or on Example 4 What are the device s settings for all Codabar selections Enter cbr Response CBRENA1 ACK SSX0 ACK CK20 ACK CCT1 ACK MIN2 ACK MAX60 ACK DFT ACK This response indicates that the device s Codabar Codin...

Страница 128: ...ate SYN T CR Deactivate SYN U CR The scanner scans until a barcode has been read until the deactivate com mand is sent or until the serial time out has been reached see Serial Trigger Time Out on page 3 5 for a description and the serial command on page 12 8 Resetting the Factory Settings If you aren t sure what programming options are in your scanner or you ve changed some options and want the fa...

Страница 129: ... Lock KBDSTY2 2 5 Emulate External Keyboard KBDSTY5 2 5 Automatic Caps Lock KBDSTY6 2 5 Keyboard Modifiers Control ASCII Off KBDCAS0 2 5 Control ASCII On KBDCAS1 2 5 Turbo Mode Off KBDTMD0 2 6 Turbo Mode On KBDTMD1 2 6 Numeric Keypad Off KBDNPS0 2 6 Numeric Keypad On KBDNPS1 2 6 Auto Direct Conn Off KBDADC0 2 6 Auto Direct Conn On KBDADC1 2 6 Serial Port Connection RS 232 PAP232 2 7 Baud Rate 300 ...

Страница 130: ...ty None 232WRD2 2 8 8 Data 1 Stop Parity Odd 232WRD8 2 8 8 Data 1 Stop Parity Mark 232WRD14 2 8 8 Data 1 Stop Parity Space 232WRD11 2 8 RS 232 Handshaking RTS CTS Off 232CTS0 2 11 RTS CTS On 232CTS1 2 11 XON XOFF Off 232XON0 2 11 XON XOFF On 232XON1 2 11 ACK NAK Off 232ACK0 2 11 ACK NAK On 232ACK1 2 11 Wand Emulation Connection Same Code Format WNDPAT0 2 11 Code 39 Format WNDPAT1 2 11 Wand Emulati...

Страница 131: ...ons Scan Rate 67 s s SCNPFM0 3 1 135 s s SCNPFM1 3 1 270 s s SCNPFM2 3 1 Beeper Volume Off BEPLVL0 3 1 Low BEPLVL1 3 1 Medium BEPLVL2 3 1 High BEPLVL3 3 1 Beeper Tone Normal Beep BEPBIP0 3 2 Short Beep BEPBIP1 3 2 Scan Voting Voting Normal DECVLV0 3 2 Voting High DECVLV1 3 2 Reduce Quiet Zone Don t Reduce Quiet Zone DECRQZ0 3 2 Reduce Quiet Zone DECRQZ1 3 2 Reread Delay Short RRDDLY0 3 3 Medium RR...

Страница 132: ...EBK2 4 3 Clear One Prefix PRECL2 4 3 Clear All Prefixes PRECA2 4 3 Suffix Add Suffix SUFBK2 4 3 Clear One Suffix SUFCL2 4 3 Clear All Suffixes SUFCA2 4 3 Function Code Transmit Enable RMVFNC0 4 6 Disable RMVFNC1 4 6 Intercharacter Delay DLYCHR 4 7 User Specified Intercharacter Delay Delay Length DLYCRX 4 7 Character to Trigger Delay DLY_XX 4 7 Interfunction Delay DLYFNC 4 8 Intermessage Delay DLYM...

Страница 133: ... 2 100 HLCSPD1 6 2 Non Decoded Output Laser Emulation Polarity Black High HLCPOL0 6 2 White High HLCPOL1 6 2 Non Decoded Output Laser Emulation Idle Low HLCIDL0 6 3 High HLCIDL1 6 3 Disabling the Secondary Interface Disable 2IF_END 6 3 Enable 2IF_EN1 6 3 Secondary Trigger Mode Manual Trigger 2IFTRG0 6 3 Automatic Trigger 2IFTRG1 6 3 Manual Trigger Low Power 2IFTRG2 6 3 Low Power Time Out 2min 2IFL...

Страница 134: ...n C39ENA1 7 6 Code 39 Start Stop Char Don t Transmit C39SSX0 7 6 Transmit C39SSX1 7 6 Code 39 Check Char No Check Char C39CK20 7 7 Validate But Don t Transmit C39CK21 7 7 Validate and Transmit C39CK22 7 7 Code 39 Message Length Minimum 0 48 0 C39MIN 7 7 Maximum 0 48 48 C39MAX 7 7 Code 39 Append Off C39APP0 7 7 On C39APP1 7 7 Code 32 Pharmaceutical PARAF Off C39B320 7 8 On C39B321 7 8 Code 39 Full ...

Страница 135: ...l Code 2 of 5 Settings R25DFT 7 13 Code 2 of 5 Off R25ENA0 7 13 On R25ENA1 7 13 Code 2 of 5 Message Length Minimum 1 48 4 R25MIN 7 13 Maximum 1 48 48 R25MAX 7 13 IATA Code 2 of 5 Default All IATA Code 2 of 5 Settings A25DFT 7 14 IATA Code 2 of 5 Off A25ENA0 7 14 On A25ENA1 7 14 IATA Code 2 of 5 Message Length Minimum 1 48 4 A25MIN 7 14 Maximum 1 48 48 A25MAX 7 14 Matrix 2 of 5 Default All Matrix 2...

Страница 136: ... Telepen Default All Telepen Settings TELDFT 7 20 Telepen Off TELENA0 7 20 On TELENA1 7 20 Telepen Output AIM Telepen Output TELOLD0 7 20 Original Telepen Output TELOLD1 7 20 Telepen Message Length Minimum 1 60 1 TELMIN 7 21 Maximum 1 60 60 TELMAX 7 21 UPC A Default All UPC A Settings UPADFT 7 22 UPC A Off UPAENA0 7 22 On UPAENA1 7 22 UPC A Check Digit Off UPACKX0 7 22 On UPACKX1 7 22 UPC A Number...

Страница 137: ...PECKX1 7 26 UPC E Number System Off UPENSX0 7 26 On UPENSX1 7 26 UPC E 2 Digit Addenda Off UPEAD20 7 26 On UPEAD21 7 26 UPC E 5 Digit Addenda Off UPEAD50 7 26 On UPEAD51 7 26 UPC E Addenda Required Off UPEARQ0 7 27 On UPEARQ1 7 27 UPC E Addenda Separator Off UPEADS0 7 27 On UPEADS1 7 27 EAN JAN 13 Default All EAN JAN 13 Settings E13DFT 7 28 EAN JAN 13 Off E13ENA0 7 28 On E13ENA1 7 28 EAN JAN 13 Ch...

Страница 138: ...8 2 Digit Addenda Off EA8AD20 7 32 On EA8AD21 7 32 EAN JAN 8 5 Digit Addenda Off EA8AD50 7 32 On EA8AD51 7 32 EAN JAN 8 Addenda Required Off EA8ARQ0 7 32 On EA8ARQ1 7 32 EAN JAN 8 Addenda Separator Off EA8ADS0 7 32 On EA8ADS1 7 32 MSI Default All MSI Settings MSIDFT 7 33 MSI Off MSIENA0 7 33 On MSIENA1 7 33 MSI Check Character Validate Type 10 but Don t Transmit MSICHK0 7 33 Validate Type 10 and T...

Страница 139: ...ed Default All GS1 DataBar Expanded Settings RSEDFT 7 37 GS1 DataBar Expanded Off RSEENA0 7 37 On RSEENA1 7 37 GS1 DataBar Expanded Msg Length Minimum 4 74 4 RSEMIN 7 37 Maximum 4 74 74 RSEMAX 7 37 China Post Code Default All China Post Code Settings CPCDFT 7 38 China Post Code Off CPCENA0 7 38 On CPCENA1 7 38 China Post Code Msg Length Minimum 2 80 4 CPCMIN 7 38 Maximum 2 80 80 CPCMAX 7 38 PDF417...

Страница 140: ... 1 366 1 MPDMIN 7 42 Maximum 1 366 366 MPDMAX 7 42 EAN UCC Composite Symbology Default All EAN UCC Composite Symbology Settings COMDFT 7 42 EAN UCC Composite Symbology Off COMENA0 7 42 On COMENA1 7 42 Enable UPC EAN Version Off COMUPC0 7 43 On COMUPC1 7 43 EAN UCC Composite Symbology Message Length Minimum 1 2435 1 COMMIN 7 43 Maximum 1 2435 2435 COMMAX 7 43 Selection Setting Indicates default Ser...

Страница 141: ... Rate 270 decodes per second Power Requirements 12 13 14 Models 5VDC 10 at scanner 11 15 Models 5 12VDC 10 at scanner Current Draw Scanning Standby Inrush Low Power 11 Model 5Vdc 400mA 200mA 550mA 11 Model 12Vdc 150mA 100mA 250mA 12 Model 275mA 125mA 300mA 30mA 13 Model 275mA 125mA 250mA 60µA 15 Model with USB Interface 500mA 265mA 1 2A Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Storag...

Страница 142: ... second Minimum Reflectance Difference 30 3900 Linear 40 3900PDF Decode Rate 270 decodes per second Power Requirements 5 VDC 10 at scanner Current Draw Scanning Standby Low Power 270 s s 67 s s 275 mA 125 mA 30 mA 150 mA 125 mA 30 mA Temperature Ranges Operating 32 to 122 F 0 to 50 C Storage 4 to 140 F 20 to 60 C Humidity 0 to 95 non condensing Mechanical Shock Operational after 5 drops from 5 fee...

Страница 143: ...ns 4 and 9 are populated depending on power supply voltage option Some decoders may have 12V on pins 4 or 9 Connect to 5VDC ONLY Conventional laser data format is provided at the modular connector in the scanner handle The inter face cable is terminated with a 10 pin modular plug and a 9 pin Type D squeeze to release connector that is compatible with all Honeywell terminals Start of scan Digital b...

Страница 144: ...11 8300XX 11E 3800XX 15 Power Connection Refer to table on page 13 1 2 Cord shield 3 Prog 1 4 Supply ground 5 Terminal clock 6 Terminal data 7 Power connection Refer to table on page 13 1 8 Keyboard data 9 Keyboard clock 10 Decoded output data format provided at 10 pin RJ41 modular connector in scanner handle ...

Страница 145: ...ed to 5 Volt power 4 Supply ground 5 6 Barcode data output 7 5 Volt power connection 8 9 10 Barcode data output 5 Volt power connection 9 Pin Type D Female connects to your terminal Supply ground Cord shield Decoded output data format provided at 10 pin RJ41 modular connector in scanner handle 1 2 3 4 5 1 4 9 8 7 6 ...

Страница 146: ... scanner handle 1 2 Cord shield 3 Tied to 5 Volt power 4 Supply ground 5 Receive data Serial data to scanner 6 Transmit data Serial data from scanner 7 5 Volt power connection 8 Request to send data 9 Clear to send data 10 Decoded output data format provided at 10 pin RJ41 modular connector in scanner handle ...

Страница 147: ...13 7 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the scanner handle 1 2 Data 3 4 Supply ground 5 6 7 5 volt power connection 8 9 10 Data ...

Страница 148: ...13 8 ...

Страница 149: ...The scanner s housing may also be cleaned the same way Inspecting Cords and Connectors Inspect the scanner s interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replacement Cable replacement instructions are on page 14 1 Replacing the Interface Cable The sta...

Страница 150: ... while maintaining pressure on the paper clip then remove the paper clip 6 Replace with the new cable Insert the connector into the opening and press firmly The connector is keyed to go in only one way and will click into place Troubleshooting The scanner automatically performs self tests whenever you turn it on If your scanner is not functioning properly review the following Troubleshooting Guide...

Страница 151: ...er may not be programmed for the appropriate terminal interface For example you scan 12345 and the host displays es Reprogram the scanner with the correct Plug and Play or Terminal selection barcode See Chapter 1 and Chapter 2 2 The scanner may not be programmed to output your barcode data properly For example you scan 12345 and the host displays A12345B Reprogram the scanner with the proper symbo...

Страница 152: ...14 4 ...

Страница 153: ...1 3535 9100 Fax 55 21 3535 9105 E mail brsuporte honeywell com Mexico Telephone 803 835 8000 E mail latechsupport honeywell com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail eurosupport honeywell com Asia Pacific Telephone Hong Kong 852 3188 3485 or 2511 3050 Telephone China 86 21 6361 3818 E mail aptechsupport honeywell com Japan Telephone 813 5770 6312 E ma...

Страница 154: ...ell com Brazil Telephone 55 21 3535 9100 Fax 55 21 3535 9105 E mail brservice honeywell com Mexico Telephone 52 55 5203 2100 Fax 52 55 5531 3672 E mail mxservice honeywell com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euservice honeywell com Asia Pacific Telephone 852 2511 3050 Fax 852 2511 3557 E mail apservice honeywell com Japan Telephone 813 5770 6312...

Страница 155: ...ter within the War ranty Period and Honeywell determines to its satisfaction that the product is defective due to defects in materials or workmanship Honeywell at its sole option will either repair or replace the product without charge except for return shipping to Honeywell EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES...

Страница 156: ...f any peripherals not provided by the manufacturer may result in damage not covered by this warranty This includes but is not limited to cables power supplies cra dles and docking stations Honeywell extends these warranties only to users of the products These warranties are non transferable The duration of the limited warranty for the 3800 3900 is for five 5 years ...

Страница 157: ......

Страница 158: ......

Страница 159: ......

Страница 160: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B ...

Страница 161: ...essage MicroPDF417 MicroPDF417 Test Message Code 93 123456 9 Code 2 of 5 123456 Matrix 2 of 5 6543210 EAN UCC Composite 01 12345678901231 10 123456789 11 001205 3202 001234 Symbology with GS1 DataBar Limited GS1 DataBar 01 00123456789012 ...

Страница 162: ...Programming Chart 0 2 6 1 7 5 4 3 8 9 ...

Страница 163: ...Programming Chart A C Save B Discard F E D ...

Страница 164: ...Honeywell 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 38 3900 DO UG Rev H 11 08 ...

Отзывы: