6 - 8
example, B2000454657374 will compare the string at the current
cursor position with the 4 character string “Test.”
Refer to the
ASCII Conversion Chart (Code Page 1252)
for decimal, hex and character codes.
Check for a number
EC Check to make sure there is an ASCII number at the current cursor
position. The format is aborted if the character is not numeric.
Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the
current cursor position. The format is aborted if the character is not
numeric.
Insert a delay
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting
from the current cursor position. Syntax = EFnnnn where nnnn stands
for the delay in 5ms increments, up to 9999. This command can only
be used with keyboard wedge interfaces.
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as
read, including prefixes and suffixes.
You may wish to require the data to conform to a data format you have created
and saved. The following settings can be applied to your data format:
Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted.
Data Formatter On, Not Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not
transmitted.
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted. Any data that does not match your data format
requirements generates an error tone and the data in that bar code is not
transmitted. If you wish to process this type of bar code without generating
an error tone, see
Data Format Non-Match Error Tone
.
Data Formatter Off
Содержание 1900GSR-2
Страница 1: ... Xenon 1900 1902 Area Imaging Scanner User s Guide ...
Страница 12: ...CCB01 010BT Base Item Number Serial Number and Revision Information location Compliance Label location ...
Страница 60: ...2 28 ...
Страница 93: ...3 33 ESC 8 Razz or error tone to indicate a decode communication to host was unsuccessful Command Action ...
Страница 94: ...3 34 ...
Страница 136: ...6 12 ...
Страница 212: ...8 20 ...
Страница 220: ...9 8 ...
Страница 226: ...10 6 ...
Страница 274: ...12 8 ...
Страница 280: ...13 6 ...
Страница 291: ......
Страница 292: ......
Страница 295: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...
Страница 296: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Страница 298: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 Xenon UG Rev B 6 10 ...