background image

33-00248EFS-07

Tools needed to install Inline Supply 

Ventilator

    Standard screwdriver

    Level
    Duct sealing tape
    Hex drivers (5/16 in. studs, 1/4 in. brackets)

Application Considerations

•  The VNT2200 can be installed in multiple positions, 

horizontal or vertical.

•  Install the unit with space to access the main access door 

and the side access panel for maintenance and service.

•  To ensure quiet operation, do not install the device directly 

on the structural supports of the home.

•  The product is for residential applications only. Must be 

installed in accordance with all national and local regulations, 

building and safety codes.

Mounting the Inline Supply Ventilator

STEP ONE: Preparation

Ensure you have all parts and tools necessary to perform the 

installation. Mounting brackets/hardware are included in the 

box.

STEP TWO: Installation Area

The VNT2200 unit should be installed in a mechanical room 

or as close to an outside wall as possible. 

The contractor should install the unit in an area that allows 

the homeowner easy access for maintenance. It is very 

important to install an electric receptacle (120 Vac) near the 

unit, a separate circuit breaker is also recommended.

NOTE:  Installation is not recommended in unconditioned 

areas such as an attic or crawl space where the 

temperature could fall below -40 ºF (-40 ºC) or 

exceed 160 ºF (71 ºC).

NOTE:  Minimum distance from exterior is 5 ft. (1.52 m).

NOTE:  Ducting in unconditioned areas must be fully sealed 

and insulated, per local ordinances and codes.

NOTE:  The unit must be mounted to something that can 

support 30 lbs. (13.6 kg)

STEP THREE: Wiring

Connect control device to the VENT terminals. No tools are 

required to install wires to the VENT terminals; Simply push 

the wire into the terminal and verify the connection by gently 

tugging on the wire. The damper control wires will be pre-

wired in the factory to the AUX terminals (24 V).

STEP FOUR: Checkout

1. Ensure mesh filter (and optional media filter) is installed 

and seated correctly. 

2. Apply power to the unit by plugging in the 120 V cord. 

3. Initiate a ventilation call from each of the external controls. 

Verify that the VNT2200 unit turns on. 

4. Return the external controls to the desired settings. 

5. Inspect the ducting to ensure that there are no kinks and 

correct as necessary.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a) Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including the fire-rated construction.

b) When cutting or drilling into a wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

Important Installation Requirements

Example Installation

Personal Safety

•  Wear safety glasses while installing the unit.

•  Do not cut into any air conditioning or 

electrical line.

•  Follow professional safety standards and 

all local codes for plumbing, electrical, and 

mechanical considerations.

WARNING

To reduce the risk of Fire or Electric 

Shock, do NOT use this fan with any solid-state 

speed control device.

Failure to comply with these requirements 

will result in voided warranty, improper 

installation, and service callbacks.

M36747

FRESH AIR
INTAKE HOOD
WITH SCREEN

FRESH
AIR

VENTILATION
CONTROLLER

FRESH AIR INTAKE DUCT

POWER
VENTILATOR

AIR FLOW

FILTER

FURNACE/AIR HANDLER

EXTERIOR 
WALL

 

VNT2200A1000 Inline Supply Ventilator

 

QUICK START GUIDE

Содержание VNT2200A1000

Страница 1: ...l device to the VENT terminals No tools are required to install wires to the VENT terminals Simply push the wire into the terminal and verify the connection by gently tugging on the wire The damper co...

Страница 2: ...ir Filtering Appliance E187216 HVI Home Ventilation Institute 2100 Certified Standards and Certifications 2015 I Codes International Residential Code IRC International Energy Conservation Code IECC In...

Страница 3: ...sitif de r gulation aux bornes VENT Aucun outil n est requis pour raccorder le c ble aux bornes VENT il suffit d enfoncer les extr mit s du c ble dans les bornes et de s assurer de la bonne connexion...

Страница 4: ...4 Dimensions en pouces mm BESOIN D AIDE Pour obtenir de l aide sur ce produit ou pour recevoir le guide d installation complet veuillez consulter le site http honeywellhome com ou communiquer avec le...

Страница 5: ...ecte el dispositivo de control a los terminales de VENT No se requieren herramientas para instalar cables en los terminales de VENT Simplemente empuje el cable dentro del terminal y verifique la conex...

Страница 6: ...TA AYUDA Para obtener ayuda con este producto o para obtener la gu a de instalaci n completa visite http honeywellhome com o llame al n mero gratuito de Atenci n al Cliente 1 800 468 1502 MS36746 14 7...

Страница 7: ......

Страница 8: ...and its affiliates Tous droits r serv s La marque de commerce Honeywell Home est utilis e avec l autorisation d Honeywell International Inc Ce produit est fabriqu par Resideo Technologies Inc et ses...

Отзывы: