background image

Product Specification Sheet • EN0H-1201GE23 R0219 • Subject to change

1

EN0H-1201GE23 R0219

Backflow Preventers

RV280

Controllable anti-pollution check valve EA type

with internal thread

APPLICATION

Check valves of this type are for use as an independent 
means of preventing reverse water flow.

They can also be used for industrial, commercial and similar 
systems where back pressure, backflow and back syphonage 
must be prevented.

The classicfications of appliances to meet these 
requirements are specified in EN 1717.

SPECIAL FEATURES

Universal application

Suitable for installation in any position

Creates no shock pressure loadings

Low pressure loss

All materials are UBA conform

TECHNICAL DATA

Media

Medium: 

Drinking water

Connections/Sizes

Connection size: 

1

/

2

" - 2" 

Pressure values

Max. operating pressure: 

16 bar

Opening pressure: 

ca. 0.05 bar 

Operating temperatures

Max. operating temperature 
medium: 

65 °C accord. DIN EN 13959

(short term up to 90 °C)

Specifications

Liquid category: 

2 (no hazardous materials)