background image

Owner’s Manual

Read and save these 

instructions.

For help please visit  

honeywellhome.com

RLV4305A1000

Programmable 

Thermostat

Application

This thermostat is designed to control an electric heating system such as a baseboard 

heater, a radiant ceiling, a convector or a fan-forced heater.
The thermostat 

CANNOT

 be used with:

• 

a resistive load under 0.83 A

• 

a resistive load over 14.6 A

• 

a system driven by a contactor or a relay (inductive load)

• 

a central heating system.

WARNING Electrical Shock Hazard.

This thermostat is a line voltage control (120–240 Volts). Do not install it if you 

are not completely familiar with house wiring. If handled improperly, there is risk 

of electric shock hazard, which may cause serious injury or death.

Do you need assistance? We are here to help.

Call 1-800-831-2823 for wiring assistance before returning the 

thermostat to the store.

Содержание RLV4305A1000

Страница 1: ...istive load under 0 83 A a resistive load over 14 6 A a system driven by a contactor or a relay inductive load a central heating system WARNING Electrical Shock Hazard This thermostat is a line voltage control 120 240 Volts Do not install it if you are not completely familiar with house wiring If handled improperly there is risk of electric shock hazard which may cause serious injury or death Do y...

Страница 2: ...y with local electrical codes This thermostat has tinned copper wires for line and load connections Special CO ALR solderless connectors must be used if these wires will be connected to aluminium conductors Install the thermostat onto an electrical box Install the thermostat about 5 ft 1 5 m high on an inside wall facing the heater Avoid locations where there are air drafts such as the top of a st...

Страница 3: ...ng the provided screws 3 Insert the screws through either the right or left pair of mounting holes on the thermostat NOTE If there is a protective film or sticker on the thermostat s screen peel it off 4 Apply power to the heating system Verify the installation by checking that the heater can be turned on by raising the setpoint using the Up button and off by lowering the setpoint using the Down b...

Страница 4: ...ock 3 Press the button to exit The clock must be set when the time is incorrect or flashes on the screen Controls Day button Hour button Minute button Program button Return button Mode button see pages 5 and 6 Backlit screen Up and Down buttons The screen is backlit for 12 seconds when you press any button ...

Страница 5: ...creen The current period name also appears unless the thermostat has not been programmed with a schedule You can program up to 4 periods Wake Leave Return or Sleep in a day You can set 2 different programs one for the weekdays Monday to Friday and another one for the weekend Saturday and Sunday The thermostat uses the following default schedule Monday to Friday Saturday Sunday Period Start Time Te...

Страница 6: ...on until Standby appears on the screen In this mode the setpoint temperature cannot be displayed or modified For frost protection heating will turn on only to prevent the room temperature from dropping below 41 F 5 C 2 Press the Hour and Min buttons to set the start time of the displayed period NOTE To cancel the period press the Mode button Instead of displaying the start time of the period the t...

Страница 7: ...lt Setting Temperature unit F C F Time format 12 hr 24 hr 12 hr Fan1 No Yes No Away temperature2 41 F 86 F 5 0 C 30 0 C 59 F 15 0 C Daylight saving time3 On Off Off Year4 00 99 09 Month4 01 12 01 Day4 01 31 01 Early start5 On Off Off Minimum setpoint 41 F 86 F 5 0 C 30 0 C 41 F 5 0 C Maximum setpoint 41 F 86 F 5 0 C 30 0 C 86 F 30 0 C Keypad lock6 On Off Off 1 Fan Place at Yes if you have a fan fo...

Страница 8: ...Your thermostat requires little or no attention Most problems can generally be traced to the following Problem Solution s Thermostat is hot This condition is normal Ensure that the heater capacity does not exceed the thermostat s maximum load Wrong temperature is displayed Correct it if any of the following situations exists The thermostat is exposed to an air draft The thermostat is located near ...

Страница 9: ...dicate it is reset and will then return to normal display Power outage During a power outage the thermostat display remains lit for the first 2 minutes During this time the LP low power indicator appears and all buttons are disabled Then the screen turns blank The settings are stored in memory When power returns the thermostat returns to the mode of operation preceding the power outage If the powe...

Страница 10: ...0 831 2823 Customer Care will make the determination whether the product should be returned to the following address Resideo Return Goods Dock 4 MN10 3860 1985 Douglas Dr N Golden Valley MN 55422 or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Resideo that the defect was caused by damag...

Страница 11: ...tiva inferior a 0 83 A una carga resistiva superior a 14 6 A un sistema accionado por un contactor o un relé carga inductiva un sistema de calefacción central WARNING Riesgo de descarga eléctrica Este termostato es un control de tensión de línea 120 240 V No lo instale si no conoce bien el cableado de su hogar La manipulación incorrecta de este termostato puede causar riesgos de descargas eléctric...

Страница 12: ... termostato tiene cables de cobre estañado para las conexiones de línea y de carga Se deben utilizar conectores especiales sin soldadura CO ALR si los cables se conectarán a conductores de aluminio Instale el termostato en una caja eléctrica Instale el termostato a aproximadamente 5 pies 1 5 m de altura en una pared interior y orientado hacia el calentador Evite lugares donde haya corrientes de ai...

Страница 13: ...ica 3 Inserte los tornillos en el par de orificios de montaje ubicados a la derecha o izquierda del termostato NOTA Si hay una película protectora o una etiqueta adhesiva en la pantalla del termostato retírela 4 Conecte la energía del sistema de calefacción Compruebe la instalación controlando que el calentador se pueda encender y apagar para ello suba el punto de ajuste con el botón de ajuste arr...

Страница 14: ...día 2 Use los botones Hour hora y Min minutos para configurar el reloj 3 Presione el botón para salir Controles Botón de día Botón de hora Botón de minutos Botón de programación Botón Intro Botón de modo consulte las págs 15 y 16 Pantalla con luz de fondo Botones de ajuste arriba y abajo La pantalla se ilumina durante 12 segundos cuando presiona cualquier botón ...

Страница 15: ...a También se muestra el nombre del período actual a menos que el termostato no esté programado con un cronograma Puede programar hasta 4 períodos Wake despertar Leave salir Return regresar Sleep dormir en un día Puede configurar 2 programas diferentes uno para los días de semana lunes a viernes y otro para el fin de semana sábado y domingo El termostato usa el siguiente cronograma predeterminado L...

Страница 16: ...zca Standby en espera en la pantalla En este modo la temperatura del punto de ajuste no se puede mostrar ni modificar Para proteger contra el congelamiento la calefacción se encenderá únicamente para evitar que la temperatura ambiente descienda por debajo de 41 F 5 C 2 Presione los botones Hour hora y Min minutos para configurar la hora de inicio del período mostrado NOTA Para cancelar el período ...

Страница 17: ...hr 24 hr 12 hr Ventilador1 No Yes No Sí No Temperatura en ausente2 41 F 86 F 5 0 C 30 0 C 59 F 15 0 C Horario de verano3 On Off activado desacti vado Off desactivado Año4 00 99 09 Mes4 01 12 01 Día4 01 31 01 Arranque anticipado5 On Off activado desacti vado Off desactivado Punto de ajuste mínimo 41 F 86 F 5 0 C 30 0 C 41 F 5 0 C Punto de ajuste máximo 41 F 86 F 5 0 C 30 0 C 86 F 30 0 C Bloqueo del...

Страница 18: ... solución de problemas Si tiene dificultades con el termostato intente seguir las sugerencias que se indican a continuación La mayoría de los problemas pueden corregirse rápida y fácilmente PROBLEMA SOLUCIONES El termostato está caliente Esto es normal Asegúrese de que la capacidad del calentador no supere la carga máxima del termostato Se muestra una temperatura incorrecta Corríjala si se present...

Страница 19: ...tato aparecerá rSt reset reinicio durante 2 segundos para indicar que se reinició y luego volverá a la pantalla normal Corte de energía Durante un corte de energía la pantalla del termostato permanece encendida durante los primeros 2 minutos Durante ese tiempo aparece el indicador LP low power suministro eléctrico bajo y se deshabilitan todos los botones A continuación la pantalla se pone en blanc...

Страница 20: ...al cliente de Resideo al 1 800 831 2823 En el Servicio de atención al cliente determinarán si el producto debe ser devuelto a la siguiente dirección Resideo Return Goods 1985 Douglas Dr N Golden Valley MN 55422 o si se le puede enviar un producto de reemplazo Esta garantía no cubre los gastos de remoción ni de reinstalación Esta garantía no se aplicará si Resideo demuestra que el defecto fue causa...