The Communication Modules allow the control panel to communicate with the Central Station via the cellular radio network. The 
PROLTE Series includes the following models: 

PROLTE-A (US/Canada, AT&T Network) 
PROLTE-V (US, Verizon network) 
PROTLTE-CN (Canada, Bell network) 

The 

PROLTE Series

 wireless communications module is intended to provide compatible PRO Series control panels with a cellular

 

connection with the central monitoring station. The module connects directly to the control panel and is powered via the control panel’s 
connection. 

Compatible Control Panels: 

PROA7PLUS Series – Quick Installation Guide P/N

 

800-25079 or higher

PROH8PLUS Series - Quick Installation Guide

 

P/N

 

800-25093 or higher. 

Installing the Module in the PROA7PLUS Series 

!

 

Ensure that all electrical power is removed from the control before installing the module. Unplug the 
power supply and disconnect the backup battery. 

1.  Affix the provided FCC/IC label (P/N 800-25167 for 

the PROLTE-A, 800-25168 for the PROLTE-V OR 
800-25170 for the PROLTE-CN) on the control’s case 
back (refer to Figure 1). 

2.  If the Control Panel is not powered up proceed to 

step 7. If the Control Panel is powered up, disarm the 
system and wait 30-60 seconds: 

3.  Unplug the power supply. 

4.  Remove the screw securing the control to the wall or 

desk mount. 

5.  Remove the control from the wall or desk mount. 

6.  Disconnect the battery. 

QS-061-V0

CONTAINS MODULE:

FCC ID: RI7LE910NAV2

IC:5131A-LE910NAV2

C

O

N

T

A

IN

S

 M

O

D

U

L

E

:

F

C

C

 I

D

R

I7

L

E

9

1

0

N

A

V

2

IC

:5

1

3

1

A

-L

E

9

1

0

N

A

V

2

C

O

N

T

A

IN

MO

D

U

L

E:

F

C

C

 I

D

R

I7

L

E9

1

0

SVV2

O

R

ADEMCO INC. PROA7PLUS SERIES

FCC / ISED STATEMENT

This device complies with Part 15 of the FCC Rules,
and ISED’s license-exempt RSSs. Operation is subject 
to the following two conditions: (1) This Device may 
not cause harmful interference. (2) This device must 
accept any interference received, including 
interference that may cause undesired operation.
FCC ID:  CFS8DL-GRIPAIO7
IC:  573F-GRIPAIO7             HVIN:  GRIPAIO7

 

Figure 1. FCC/IC Label Location 

 

7.  Remove the left side from the control. 

8.  Insert the PROLTE Series module into the slot on the 

left side of the control as shown in Figure 2 and 
ensure the receptacle is securely seated on the 
control’s edge connector. 

9.  Secure with the screw. 

10.  Install the left side cover. 

11.  Connect the battery. 

12.  Install the control on the wall or desk mount. 

13.  Plug the power supply into a 24-hour, 110VAC 

unswitched outlet. 

 

PROLTE-SERIES

MODULE

COVER

MACHINE

SCREW

QS-057-V0

EXT

INT

 

Figure 2. Installing the PROLTE Module 

 

 