Honeytek A6013L Скачать руководство пользователя страница 1

 

A6013L 

 

  DIGITAL C METER OPERATION MANUAL 

1.

 

FEATURES 

 

Easy and correct readout. 

 

High measuring accuracy. 

 

Measurements  are  possible  even  under  a  strong 

magnetic field. 

 

LSI-circuit provides high reliability and durability. 

 

Input overload protection is provided. 

 

LCD  display  for  low  power  consumption  and  clear 

readout even in bright ambient light conditions. 

 

In-line pushbuttons allow one hand operation. 

 

Light-weight  and  compact  construction  for  easy 

operation. 

 

Low  battery  condition  is  indicated  on  the  LCD 

display. 

 

 

 

 

2. Panel Layout   

 

LCD Display: 3½ 

digits, character 

15mm high 

 

Back Light Button 

Switch: Press this 

button to switch on 

back light if the dark 

circumstance light 

makes the reading 

difficulty when measuring, the light will be 

automatically turned off in 5 seconds. Press again to 

switch it on again. If the battery is in weak power, the 

light will be dimmed. 

 

Rotary Switch: use this switch to select ranges   

 

“COM”Input Jack 

 

 “+” Input Jack   

 

Data-hold Switch (HOLD) 

    Zero ADJ. 

 

 

2.

 

SPECIFICATIONS 

2-1.GENERAL SPECIFICATIONS 

Display          :LCD  (Liquid  Crystal  Display)  Max 

Indication 1999. 

LCD Backlight and data hold. 

Measurement:C (Capacitance) 

Range            :single 9 position, whole range value (from 

0.1pF to 20000uF)                     

Zero Adjustment :Manual (range:

±

20pF) 

Calibrate Adjustment :Have two internal adjustment. One 

is panel Zero adjustment. 

Over-input :Display shows “1”. 

Sampling Time :3/second 

Operating Temp :0

  to 40

℃. 

Operating Humidity :80% MAX.R.H. 

Power  Supply:Single,  standard  9  volt  battery.  NEDA 

1604IEC6F22 

Battery Life :Alkaline type approx.: 200 hours. 

 

 

Zinc-Carbon type approx.: 100 hours 

Typical consumption current :3~4mA (200pF-200uF) 

Standard Accessories: Test alligator clips (red & 

black)…1 pair. 

                  Instruction manual………………...1 pc. 

 

2-2. ELECTRICAL SPECIFICATION 

      Accuracy is 

±

(percentage of r number of digit) 

at 23

±

5

,<80%RH.   

Range 

Accuracy 

Resolution 

Test 

Frequency 

Max 

indication 

200pF 

±

(0.5%+1d) 

0.1pF 

820Hz 

199.9pF 

2nF 

0.001nF 

1.999nF 

20nF 

0.01nF 

19.99nF 

200nF 

0.1nF 

199.9nF 

2uF 

0.001uF 

1.999uF 

20uF 

0.01uF 

82Hz 

19.99uF 

200uF 

0.1uF 

8.2Hz 

199.9uF 

2000uF 

±

(2.0%+2d) 

±

(4.0%+10d) 

1uF 

1999uF 

20mF 

0.01mF 

19.99mF 

 

    pF=  Pico  Farad(10

-12

F  )

nF=  nan  Farad(10

-9

F).  uF= 

micro Farad(10

-6

F) 

    Zero Error: 

±

20pF 

    Excitative voltage: Max.2.8Vrms 

    Overload Rating: Protection by a 0.2A/250V fuse. 

 

Отзывы: