A6013L
DIGITAL C METER OPERATION MANUAL
1.
FEATURES
Easy and correct readout.
High measuring accuracy.
Measurements are possible even under a strong
magnetic field.
LSI-circuit provides high reliability and durability.
Input overload protection is provided.
LCD display for low power consumption and clear
readout even in bright ambient light conditions.
In-line pushbuttons allow one hand operation.
Light-weight and compact construction for easy
operation.
Low battery condition is indicated on the LCD
display.
2. Panel Layout
①
LCD Display: 3½
digits, character
15mm high
②
Back Light Button
Switch: Press this
button to switch on
back light if the dark
circumstance light
makes the reading
difficulty when measuring, the light will be
automatically turned off in 5 seconds. Press again to
switch it on again. If the battery is in weak power, the
light will be dimmed.
③
Rotary Switch: use this switch to select ranges
④
“COM”Input Jack
⑤
“+” Input Jack
⑥
Data-hold Switch (HOLD)
Zero ADJ.
2.
SPECIFICATIONS
2-1.GENERAL SPECIFICATIONS
Display :LCD (Liquid Crystal Display) Max
Indication 1999.
LCD Backlight and data hold.
Measurement:C (Capacitance)
Range :single 9 position, whole range value (from
0.1pF to 20000uF)
Zero Adjustment :Manual (range:
±
20pF)
Calibrate Adjustment :Have two internal adjustment. One
is panel Zero adjustment.
Over-input :Display shows “1”.
Sampling Time :3/second
Operating Temp :0
℃
to 40
℃.
Operating Humidity :80% MAX.R.H.
Power Supply:Single, standard 9 volt battery. NEDA
1604IEC6F22
Battery Life :Alkaline type approx.: 200 hours.
Zinc-Carbon type approx.: 100 hours
Typical consumption current :3~4mA (200pF-200uF)
Standard Accessories: Test alligator clips (red &
black)…1 pair.
Instruction manual………………...1 pc.
2-2. ELECTRICAL SPECIFICATION
Accuracy is
±
(percentage of r number of digit)
at 23
±
5
℃
,<80%RH.
Range
Accuracy
Resolution
Test
Frequency
Max
indication
200pF
±
(0.5%+1d)
0.1pF
820Hz
199.9pF
2nF
0.001nF
1.999nF
20nF
0.01nF
19.99nF
200nF
0.1nF
199.9nF
2uF
0.001uF
1.999uF
20uF
0.01uF
82Hz
19.99uF
200uF
0.1uF
8.2Hz
199.9uF
2000uF
±
(2.0%+2d)
±
(4.0%+10d)
1uF
1999uF
20mF
0.01mF
19.99mF
pF= Pico Farad(10
-12
F )
,
nF= nan Farad(10
-9
F). uF=
micro Farad(10
-6
F)
Zero Error:
±
20pF
Excitative voltage: Max.2.8Vrms
Overload Rating: Protection by a 0.2A/250V fuse.