CONTROL UNIT
SPEED VOLUME SWITCH (Applicable type)
Measure the resistance between the Brown and Green wire terminals of the
switch side 3P connector.
Check that the resistance between the Red and Green wire terminals varies
in accordance with the switch position by operating the speed control lever.
– Turn to right (from MIN. to MAX.): Resistance increase
– Turn to left (from MAX. to MIN.): Resistance decrease
Standard: 4.0 – 6.0 kΩ
Brown
Red
Green
MAX.
MIN.
(With Control Box)