CONTROLS & FEATURES
25
FEATURES
Ground Terminal
The generator ground terminal is connected to the frame of the generator, the
metal non-current-carrying parts of the generator, and the ground terminals of
each receptacle.
Before using the ground terminal, consult a qualified electrician, electrical
inspector, or local agency having jurisdiction for local codes or ordinances that
apply to the intended use of the generator.
NEUTRAL FLOATING:
• The generator (stator winding) is isolated from the frame and from the AC
receptacle ground pin.
• Electrical devices that require a grounded receptacle pin connection will not
function if the receptacle ground pin is not functional.
Fuel Level Indicator
The fuel level indicator is a mechanical device that measures the fuel level in the tank.
To provide increased operating time, start with a full tank before operation.
Check the fuel level with the generator on a level surface. Always refuel with the
engine OFF and cool.
GROUND TERMINAL
FUEL LEVEL INDICATOR
The indicator according to the generator’s fuel level as follows:
80 % or more
60-80 %
40-60 %
20-40 %
20 % or less
Содержание EU3200i
Страница 14: ...GENERATOR SAFETY 12 ...
Страница 98: ...96 MEMO ...