SERVICING YOUR GENERATOR
73
Battery Removal
WARNING:
Battery posts, terminals, and related accessories contain lead and
lead compounds.
Wash your hands after handling.
1. Loosen the cover screw and
remove the battery cover.
2. Remove the negative (–) cable
from the battery negative (–)
terminal, and then remove the
positive (+) cable from the
battery positive (+) terminal.
3. Remove the battery holder band.
The battery gives off explosive
hydrogen gas during normal operation.
A spark or flame can cause the battery to
explode with enough force to kill or
seriously hurt you.
Wear protective clothing and a face
shield, or have a skilled mechanic
perform the battery maintenance.
COVER SCREW
BATTERY COVER
BATTERY HOLDER BAND
POSITIVE (+) CABLE
NEGATIVE (–) CABLE
31Z236200.book 73 ページ 2020年2月20日 木曜日 午後1時8分