HomeSeer | 10 Commerce Park North, Unit 10 | Bedford, NH 03110 | HomeSeer.com | Doc: HS
-
WV100
-
en
-
v1.0
HS
-
WV100+
1.25”
Z
-
Wave Valve Controller
Install Electronic Water Valve
The included electronic water valve must be installed into the existing plumbing. For whole
-
building protection, the valve should be
installed where it can turn off all of the water entering the premises. In a residential setting this is typically on the main water line
coming into the house. Variations in plumbing make it impossible to provide detailed instructions for your installation. Your situation
may require rerouting the water line, or other changes to your plumbing. It is
your responsibility
to check with your local codes de-
partment to determine if a licensed plumber is required to install the Electronic Water Valve.
*** CAUTION
-
Do NOT insert fingers into the valve as this may cause serious injury!
Install HS
-
WV100+ Z
-
Wave Water Valve Controller Unit
The water valve controller unit should be positioned near the electronic water valve.
1.Mount the water valve controller to the wall using appropriately sized hardware (not included).
2.Attach the electronic water valve cable to the
“
VALVE
”
connector on the water valve controller.
3.Attach the supplied power adapter to the
“
DC12V
”
connector on the water valve controller.
4.Power the system by plugging the power adapter into a wall outlet.
Z
-
Wave Network Installation
Inclusion
(Use this procedure to add the HS
-
WV100+ to your Z
-
Wave network).
1.Put your home automation controller into
‘
inclusion
’
mode. Consult your system
’
s manual for details.
2.Press the
“
program
”
button on the water valve controller unit. Wait for the process to finish.
Exclusion
(Use this procedure to remove the HS
-
WV100+ from your Z
-
Wave network).
1.Put your home automation controller into
‘
exclusion
’
mode. Consult your system
’
s manual for details.
2.Press the
“
program
”
button on the water valve controller unit. Wait for the process to finish.
Reset
(Use this procedure to reset the HS
-
WV100+ to factory default settings when the network primary controller is missing or otherwise inoperable).
1.Press and hold the
“
program
”
button on the water valve controller unit for 15 seconds. The LED will blink rapidly.
2.When the LED turns off, release the program button. Your water valve controller unit is now reset.
OVERVIEW & INSTALLATION
HS
-
WV100+ is a valve controller system that is designed to control the flow of water when Z
-
Wave commands are received. It may be used with compatible
home automation systems (and sensors) to mitigate water damage when leaks are detected. It may also be used for a variety of other automated or re-
motely controlled water or irrigation needs.
OPERATION
Remote Valve Operation
(use this procedure for remote or automatic control of the water valve)
HS
-
WV100+ valve controller behaves like a Z
-
Wave
“
binary
”
device, with
“
ON
”
and
“
OFF
”
values, when added to most home automation systems.
Open Valve
-
Issue
“
ON
”
command from Z
-
Wave controller or Z
-
Wave compatible home automation system.
Close Valve
-
Issue
“
OFF
”
command from Z
-
Wave controller or Z
-
Wave compatible home automation system.
Local Valve Operation
(use this procedure for convenient local control of the water valve)
Open Valve
-
Press and release the
’
Open
’
button on the water valve controller unit to open the water valve.
Close Valve
-
Press and release the
’
Close
’
button on the water valve controller unit to close the water valve.
Local Manual Valve Operation
(for use in the event of a power failure or water valve controller failure)
Our
1.25”
water valve does not include a built
-
in manual override. We recommend plumbing a bypass loop (with manual ball valves) as part of this installa-
tion to provide or prevent water flow in the event of a power failure or HS
-
WV100 unit failure.
Z
-
WAVE ASSOCIATION INFO
The HS
-
WV100+ has a single Association Group, Group 1 also known as the
“
Lifeline
”
group. Four (4) NodeIDs can be SET into Group 1. Typically the Z
-
Wave system controller will be the most important member of Group 1.
SPECIFICATIONS
Operating Temp Range
5ºC to 80ºC
Power Supply
12 VDC, 1A, UL (US, Canada), FCC
Z
-
Wave Frequency | Range
908 / 916 MHz (US) | Up To 300 Ft line of sight
Valve Type
Motorized Ball Valve
Controller Certification
Z
-
Wave Plus
Valve Certification
NSF