Install Electronic Water Valve 

 

The included electronic water valve must be installed into the existing plumbing. For whole

-

building protection, the valve should  be 

installed where it can turn off all of the water entering the premises. In a residential setting this is typically on the main water line 
coming into the house. Variations in plumbing make it impossible to provide detailed instructions for your installation. Your situation 
may require rerouting the water line, or other changes to your plumbing. It is 

your responsibility 

to check with your local codes de-

partment to determine if a licensed plumber is required to install the Electronic Water Valve.  

 

*** CAUTION 

-

 Do NOT insert fingers into the valve as this may cause serious injury! 

 

 

 

Install HS

-

WV100+ Z

-

Wave Water Valve Controller Unit

 

The water valve controller unit should be positioned near the electronic water valve.

 

1.Mount the water valve controller to the wall using appropriately sized hardware (not included).

 

2.Attach the electronic water valve cable to the 

VALVE

” 

connector on the water valve controller.

 

3.Attach the supplied power adapter to the 

DC12V

” 

connector on the water valve controller.

 

4.Power the system by plugging the power adapter into a wall outlet.

 

 

Z

-

Wave Network Installation 

 

Inclusion 

(Use this procedure to add the HS

-

WV100+ to your Z

-

Wave network).

 

1.Put your home automation controller into 

inclusion

’ 

mode. Consult your system

s manual for details.

 

2.Press the 

program

” 

button on the water valve controller unit. Wait for the process to finish.

 

 

Exclusion 

(Use this procedure to remove the HS

-

WV100+ from your Z

-

Wave network).

 

1.Put your home automation controller into 

exclusion

’ 

mode. Consult your system

s manual for details.

 

2.Press the 

program

” 

button on the water valve controller unit. Wait for the process to finish.

 

 

Reset 

(Use this procedure to reset the HS

-

WV100+ to factory default settings when the network primary controller is missing or otherwise inoperable).

 

1.Press and hold the 

program

” 

button on the water valve controller unit for 15 seconds. The LED will blink rapidly.

 

2.When the LED turns off, release the program button. Your water valve controller unit is now reset.

 

OVERVIEW & INSTALLATION

 

HS

-

WV100+ is a valve controller system that is designed to control the flow of water when Z

-

Wave commands are received. It may be used with compatible 

home automation systems (and sensors) to mitigate water damage when leaks are detected. It may also be used for a variety of other automated or re-
motely controlled water or irrigation needs.

 

OPERATION

 

Remote Valve Operation 

(use this procedure for remote or automatic control of the water valve)

 

HS

-

WV100+ valve controller behaves like a Z

-

Wave 

binary

” 

device, with 

ON

” 

and 

OFF

” 

values, when added to most home automation systems. 

 

Open Valve 

-

 Issue 

ON

” 

command from Z

-

Wave controller or Z

-

Wave compatible home automation system.

 

Close Valve 

-

 Issue 

OFF

” 

command from Z

-

Wave controller or Z

-

Wave compatible home automation system.

 

 

Local Valve Operation 

(use this procedure for convenient local control of the water valve)

 

Open Valve 

-

 Press and release the 

Open

’ 

button on the water valve controller unit to open the water valve.

 

Close Valve 

-

  Press and release the 

Close

’ 

button on the water valve controller unit to close the water valve.

 

 

Local Manual Valve Operation 

(for use in the event of a power failure or water valve controller failure)

 

Our 

1.25” 

water valve does not include a built

-

in manual override. We recommend plumbing a bypass loop (with manual ball valves) as part of this installa-

tion to provide or prevent water flow in the event of a power failure or HS

-

WV100 unit failure.

 

Z

-

WAVE ASSOCIATION INFO

 

The HS

-

WV100+ has a single Association Group, Group 1 also known as the 

Lifeline

” 

group.  Four (4) NodeIDs can be SET into Group 1. Typically the Z

-

Wave system controller will be the most important member of Group 1. 

 

SPECIFICATIONS

 

Operating Temp Range

 

5ºC to 80ºC 

 

Power Supply

 

12 VDC, 1A, UL (US, Canada), FCC

 

Z

-

Wave Frequency | Range

 

908 / 916 MHz (US) | Up To 300 Ft line of sight 

 

Valve Type

 

Motorized Ball Valve

 

Controller Certification

 

Z

-

Wave Plus

 

Valve Certification

 

NSF

 