background image

Z-Wave ZDW120 Instructions, Series 200, Release 2.2

P/D 032508

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0758-01

1

Z-Wave Radio Frequency (RF) Controlled, 500W, 120 VAC,

Two Wire, Wall Mounted Dimmer,

Series 200, Release 2.2

ZDW120

ZDW120 WALL MOUNTED DIMMER

The ZDW120 Wall Mounted Dimmer is a component of the HomePro lighting control system.   Wire the Wall
Mounted Dimmer in place of the standard wall switch according to the diagram above and program from the
Wireless Controller to operate loads.   Inclusion of the ZDW120 Wall Mounted Dimmer on the ZTH100 Wireless
Controller menu allows remote ON/OFF control and dimming of lights connected.

This Wall Mounted Dimmer is designed to work with other Z-Wave enabled devices.  Z-Wave nodes of other types
can be added to the system and will also act as repeaters if they support this function of repeating the signal
received to other modules in the system.

This product supports 40Kbps data transmission.

  This product can also be used for networking support in

systems that stream metadata. An example might include transmission of information from audio devices such
as song title, artist, and album information to various displays around the home.

As part of a Z-Wave network, the ZDW120 will also act as a wireless repeater to insure that commands intended
for another device in the network are received.  This is useful when the device would otherwise be out of the radio
range of the wireless controller.

There are no field repairable assemblies on this unit. If service is needed, the unit must be returned where
purchased.

Read and understand these instructions before installing.  This device is intended for installation in accordance
with the National Electric code and local regulations in the United States, or the Canadian Electrical Code and local
regulations in Canada.  It is recommended that a qualified electrician perform this installation.

CAUTION! 

 

To reduce the risk of overheating and possible damage 

to other equipment, do not install

to control a receptacle, a motor operated appliance, a fluorescent lighting fixture, or a transformer-supplied
appliance, but 

only permanently installed incandescent lamp fixtures

.  Make sure the lamp(s) to be controlled

directly from this dimmer total no more than 500 watts.  Retain instructions for future use.

INSTALLATION

DANGER!  -  SHOCK HAZARD.

  Make all connections with the 

POWER OFF

 to avoid injury to the installer or damage

 to the device.

1.  Strip 3/4" of insulation from the ends of the conductors (if not already done) and make connec-

tions as shown in the Wiring Diagram.  Note that the line side of the load must be switched.

HomePro

RF Home Automation

Supplied with matching

decorative switch plate

Note:

  This module must be “Included in the

Network” 

only where it will be permanently

installed

.  The proper operation of  this node in the

mesh network is dependent on it knowing its
location with respect to other nodes.  You cannot
“test bench” configure this module.

Содержание ZDW120

Страница 1: ...ul when the device would otherwise be out of the radio range of the wireless controller There are no field repairable assemblies on this unit If service is needed the unit must be returned where purchased Read and understand these instructions before installing This device is intended for installation in accordance withtheNationalElectriccodeandlocalregulationsintheUnitedStates ortheCanadianElectr...

Страница 2: ... Controller to include a unit to the network by adding it to a group method of adding a node to the network Refer to controller instructions STEP 2 The ZDW120 must be in its permanently installed location Tap either the top or bottom of the ZDW120 switch once STEP 3 You should see an indication on your Controller that the DEVICE WAS INCLUDED in the network NOTE If you have trouble adding the ZDW12...

Страница 3: ...immed by tapping or holding the switch a differing amount of times If you associate a Z Wave device into Group 2 you can turn that device on and off by tapping the top or bottom of the switch twice You can brighten or dim devices by tapping the top or bottom of the switch once and then hold it down The load attached to the ZDW120 is not affected If you associate a Z Wave device into Group 3 you ca...

Страница 4: ...One set to control how fast the dim rate is when the dimmer is locally controlled Parameter 9 and 10 3 One set to control how fast the dim rate is when the dimmer receives an ALL ON or ALL OFF command Parameter 11 and 12 These values can be changed instantly to allow various scenes and effects The first of these parameters is the dim step dim rate parameter It can be set to a value of 1 to 99 This...

Страница 5: ...DW120 is excluded from the Z Wave network by using the controller to reset the node on the ZTH100 select SETUP and scroll to RESET UNIT SUC Support There must be a Static Update Controller in your Z Wave system for this feature to work A Static Controller is one that is not moved after addition to the network The Static Controller can act as a gateway in the system since other nodes always know it...

Страница 6: ...erference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television recep...