37
Start-up
5.2
Installation
The bus is powered by the Homematic IP Wired
Access Point (HmIPW-DRAP). For further
information, please refer to the operating manual
of the corresponding Wired Access Points.
To facilitate connection to the terminals, the
green push-in terminal can be removed from the
device. To do this, release the mounting plate,
press the latch on the back next to the lock
symbol and slide the clamp out of the mounting
plate to the side (see
figure 2
).
For the installation, please proceed as follows:
• Disconnect the corresponding line of the
incoming Homematic IP Wired bus.
• Connect the Homematic IP Wired bus to the bus
connecting terminals (see
figure 3
). To connect
and loosen the single wires, press the orange
clamp using a small screwdriver.
• Place the mounting plate
(A)
in the flush-
mounted box and fasten it to the flush-mounted
box using the screws supplied (see
figure 4
).
• Place the frame of your existing switch series or
the supplied clip-on frame
(B)
to the mounting
plate (see
figure 5
).
• Place the electronic unit
(C)
of the wall-mount
remote control into the frame by fully snapping
Содержание HmIPW-WRC2