30
Operation
6
Operation
After teaching-in and installing have been performed, simple
operations are available directly on the device.
• Press the system button
(A)
shortly to switch on and
off connected loads.
Improper usage or a defective installation (e.g. low-qual-
ity or defective plugs or sockets) can lead to overheat-
ing of the pluggable switch. The integrated temperature
control automatically switches off the load. The devices
is protected against overheating and secure operation is
ensured. As soon as the temperature reaches a non-crit-
ical value, you can switch on the pluggable switch again.
Always observe the permitted ambient temperature of
the device and, if necessary, have the installation checked
for possible error sources by an expert.
7
Behaviour after power recovery
After the device has been inserted to a socket or after pow-
er recovery the pluggable switch performs a self-test/re-
start (approx. 2 seconds). The device LED flashes orange
and green briefly (LED test display). The LED will flash if
an error is detected during this test (see “8.3 Error codes
and flashing sequences” on page 33). This is repeated
continuously and the device does not perform its function.
If the test is completed without errors, the device transmits
a wireless telegram containing its status information.