Homelite HG3550 Скачать руководство пользователя страница 1

SAVE THIS MANUAL FOR FUTURE REFERENCE

Your new generator has been engineered and manufactured to a high standard for dependability, ease of operation, and 
operator safety. When properly cared for, it will give you years of rugged, trouble-free performance.

Thank you for your purchase.

DANGER:

 

You WILL be KILLED or SERIOUSLY HURT if you do not follow the instructions in this operator’s 

manual.

OPERATOR’S MANUAL

PORTABLE GENERATOR
3,500 WATT

HG3550

For Parts Call 606-678-9623 or 606-561-4983

www.mymowerparts.com

Содержание HG3550

Страница 1: ...operator safety When properly cared for it will give you years of rugged trouble free performance Thank you for your purchase DANGER You WILL be KILLED or SERIOUSLY HURT if you do not follow the instr...

Страница 2: ...National Electric Code contains several practical ways in which to establish a good ground source If a steel or iron rod is used it should be at least 5 8 in diameter and if a nonferrous rod is used...

Страница 3: ...local authorities in your area before use Do not touch bare wire or receptacles Do not use generator with electrical cords which are worn frayed bare or otherwise damaged Before storing allow the engi...

Страница 4: ...3 feet away from all types of combustible material Do not operate generator near hazardous material Do not operate generator at a gas or natural gas filling station Do not touch the muffler or cylind...

Страница 5: ...oduct Safety Alert Precautions that involve your safety Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Toxic Fumes Running generator gives o...

Страница 6: ...wer tool operation always wear safety goggles or safety glasses with side shields and when needed a full face shield We recommend Wide Vision Safety Mask for use over eyeglasses or standard safety gla...

Страница 7: ...windows vents or doors Fumes from the unit can kill GROUNDING WARNING National Electric Code requires generator to be grounded to an approved earth ground Check for any fuel overflow or leaking Stop t...

Страница 8: ...appliance being used compared to the rated output of the generator Motor Size H P Running Watts Watts Required to Start Motor Repulsion Induction Capacitor Split Phase 1 8 275 600 850 1200 1 6 275 60...

Страница 9: ...gine as described later in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device ope...

Страница 10: ...TCH RECOIL STARTER GRIP AIR FILTER CHOKE LEVER AC CIRCUIT BREAKER GROUND TERMINAL 240 VOLT AC 30 AMP RECEPTACLE 120 VOLT AC 20 AMP GFCI RECEPTACLES FUEL TANK OIL CAP DIPSTICK FUEL VALVE FUEL LEVEL GAU...

Страница 11: ...ng the engine oil the oil drainage bolt is loos ened to allow old engine oil to be drained RECEPTACLES Your generator has the following single phase 60 Hz out lets two 120 Volt AC 20 Amp GFCI receptac...

Страница 12: ...garages crawl spaces or other partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a g...

Страница 13: ...NG FUEL STABILIZER Fuel gets old oxidizes and breaks down over time Add ing a fuel stabilizer extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system Foll...

Страница 14: ...6 times NOTE Do not allow the grip to snap back after starting return it gently to its original place Allow the engine to run for 30 seconds then move the choke lever to the RUN position Switch the A...

Страница 15: ...er performance and long life keep air filters clean Rotate the knob counterclockwise to release Lift the air filter cover toward you and up to remove from the air filter unit Remove the filter element...

Страница 16: ...und base of spark plug Remove spark plug using wrench provided Inspect spark plug for damage and clean with a wire brushbeforereinstalling Ifinsulatoriscrackedorchipped spark plug should be replaced N...

Страница 17: ...UEL TANK Turn the engine switch OFF O Close fuel valve Remove the fuel line from the petcock by squeezing the ends of the retaining clip and sliding the fuel line off Install one end of a drain line o...

Страница 18: ...oline stabilizers formulated to extend storage life For recommendations contact your nearest Baja authorized service center MAINTENANCE MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours...

Страница 19: ...tive Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise Anoccasionallight knocking or ping ing under heavy load is not a cause for concern However if th...

Страница 20: ...Page 20 WIRING DIAGRAM For Parts Call 606 678 9623 or 606 561 4983 www mymowerparts com...

Страница 21: ...ltered or modified The warranty does not extend to repairs made necessary by normal wear or by the use of parts or accessories which are either incompatible with the HOMELITE brand product or adversel...

Страница 22: ...authorized service center Be sure to provide all pertinent facts when you call or visit Please call 1 866 260 8280 for your nearest Baja authorized service center MODEL NO AND SERIAL NO The model num...

Отзывы: