background image

1

En
glish

Quick Start

Plan your Silk’n Flash&Go

 hair removal for best results!

Treatments 1-4 – plan two weeks apart

Treatments 5-7 – plan four weeks apart

Treatments 8 + – treat as needed, until desired results are achieved.

Set up Silk’n Flash&Go

!

1. Remove Silk’n Flash&Go™ HAIR REMOVAL UNIT and other components from box.

2. Verify that the DISPOSABLE LAMP CARTRIDGE is inserted properly at the tip of the device.

3. Plug the ADAPTOR cord into the Silk’n Flash&Go™ HAIR REMOVAL UNIT socket.

4. Plug the ADAPTOR into an electrical outlet. The STAND BY INDICATOR LIGHT will turn on.

Your Silk’n Flash&Go™ is now ready to start.

Treat with Silk’n Flash&Go

 safely and properly!

5. Choose areas to treat that have not had recent exposure to the sun.

6. The skin of the treatment areas should be shaved, clean, dry and free of any powders, antiperspirants 

    or deodorants. Do not wax, pluck or tweeze the hair out.   

    Shaving is an important step to get the results you want! 

7. Press the ON/STBY SWITCH.  The POWER ON INDICATOR LIGHT (orange) will turn on and 

    a fan sound (similar to the sound of a hairdryer) will start.

8. Approximately 3.5 seconds after pressing the ON/ STBY SWITCH, the READY INDICATOR LIGHT 

   (green) will turn on. The device is then ready for you to trigger the first pulse at the lowest 

    energy level.

9. If this is your first treatment - Choose the energy level. Flash&Go offers 5 levels of energy from 

   1(the lowest) to 5 (the highest). To choose the right energy level for your first treatment, test each 

    treatment area separately:

 Place the TREATMENT SURFACE on the skin and press the trigger to deliver one pulse.

 If you did not experience abnormal discomfort press the + button once and deliver one pulse on a 

   different spot at energy level 2.

 Continue testing at increased energy levels until you have reached the highest level that you feel 

   comfortable with. If within one hour you experience no adverse effects, you can start your full 

   treatment at that energy level.

 Repeat this test for each body part you intend to treat.

Skin Test

Содержание Silk'n Flash&Go

Страница 1: ...ortant step to get the results you want 7 Press the ON STBY SWITCH The POWER ON INDICATOR LIGHT orange will turn on and a fan sound similar to the sound of a hairdryer will start 8 Approximately 3 5 seconds after pressing the ON STBY SWITCH the READY INDICATOR LIGHT green will turn on The device is then ready for you to trigger the first pulse at the lowest energy level 9 If this is your first tre...

Страница 2: ... to make changes to its products or specifications to improve performance reliability or manufacturability Information furnished by Home Skinovations Ltd Is believed to be accurate and reliable at the time of publication However Home Skinovations Ltd assumes no responsibility for its use No license is granted by its implication or otherwise under any patent or patent rights of Home Skinovations Lt...

Страница 3: ...r Removal Unit A wall mount adaptor This User s Manual An Instructional DVD 1 3 The Disposable Lamp Cartridge The Silk n Flash Go all purpose DISPOSABLE LAMP CARTRIDGE can fire a limited and pre set number of light pulses regardless of the energy level of these pulses A complete series of full body treatments typically require 7 000 10 000 light pulses In addition to the regular all purpose DISPOS...

Страница 4: ...ficial tanning machines Do not expose treated areas to the sun Treating with Silk n Flash Go before or after any sun ex posure can result in adverse effects such as redness and skin discomfort Tanned skin par ticularly following sun exposure contains large quantities of the pigment Melanin all skin types and complexions including those which don t seem to tan quickly The presence of large quantiti...

Страница 5: ...may also damage your device and will void your warranty Please contact Silk n Customer Service if you have a broken or dam aged device in need of repair 5 Do not use Silk n Flash Go if If the DISPOSABLE LAMP CARTRIDGE is damaged or if its TREATMENT SURFACE is cracked chipped or missing Stop use immediately and contact Silk n Customer Service the attachments or accessories are not recommended by Ho...

Страница 6: ...up within 24 hours See your doctor if redness does not go away within 2 to 3 days Minor Increased Sensitivity to Skin The skin of the treated area is more sensitive so you may encounter dryness or flaking of the skin Minor Pigment Changes Silk n Flash Go targets the hair shaft in particular the pigmented cells in the hair follicle and the hair follicle itself Nevertheless there is risk of temporar...

Страница 7: ... level that you feel comfortable with If within one hour you experience no adverse effects you can start your full treatment at that energy level Repeat this test for each body part you intend to treat 9 Set the energy level If the energy level should be higher than the lowest press the ENERGY LEVEL SETTING BUTTONS using the or to respectively decrease or increase the energy level until the desire...

Страница 8: ...r lights are steadily lit Whenever Silk n Flash Go is turned on its energy level will automatically be reset to the lowest energy level Only one ENERGY LEVEL Indicator Light will be on To set the energy level press the Energy Level Setting Buttons using or to respectively decrease or increase the energy level The Skin Color Sensor Light based hair removal on darker skin tones can result in adverse...

Страница 9: ...LIGHT on the CONTROL PANEL will start blinking indicating that the DISPOSABLE LAMP CARTRIDGE should soon be replaced As the number of light pulses in the DISPOSABLE LAMP CARTRIDGE further decreases the REPLACE CARTRIDGE INDICATOR LIGHT blinking will grow faster Once all the pulses in a DISPOSABLE LAMP CARTRIDGE have been used the REPLACE CARTRIDGE INDICATOR LIGHT will remain steadily on indicating...

Страница 10: ...ntact your local Silk n Customer Service Center 11 Troubleshooting Do not attempt to open or repair your Silk n Flash Go device Only authorized Silk n repair centers are permitted to perform repairs Opening Silk n Flash Go may expose you to dangerous electrical components and to pulsed light energy either of which may cause serious bodily damage and or permanent eye injury Trying to open Silk n Fl...

Отзывы: