background image

2

Table of Contents ................................................................ 2

Safety Information ............................................................... 2

Warranty ............................................................................... 3

Pre-Installation .................................................................... 3

Installation ............................................................................ 6

Assembly .............................................................................. 7

Operation ........................................................................... 14

Care and Cleaning ............................................................. 15

Troubleshooting ................................................................. 15

1. 

To reduce the risk of electric shock, ensure the electricity has 
been turned off at the circuit breaker or fuse box before you 
begin.

2. 

All wiring must be in accordance with the National Electrical 
Code ANSI/NFPA 70 and local electrical codes. Electrical 
installation should be performed by a qualified licensed 
electrician.

3. 

The outlet box and support structure must be securely mounted 
and capable of reliably supporting 35 lbs. (15.9 kg). Use only 
UL Listed outlet boxes marked”Acceptable for Fan Support of 
35 lbs. (15.9 kg) or less”.

4. 

The fan must be mounted with a minimum of 7 ft (2.1 m) 
clearance from the trailing edge of the blades to the floor.

5. 

Do not operate the reversing switch while the fan blades are 
in motion. You must turn the fan off and stop the blades before 
you reverse the blade direction.

6. 

Do not place objects in the path of the blades.

7. 

To avoid personal injury or damage to the fan and other items, 
use caution when working around or cleaning the fan.

8. 

Electrical diagrams are for reference only. Light kits that are 
not packed with the fan must be UL-listed and marked suitable 
for use with the model fan you are installing. Switches must be 
UL General Use Switches. Refer to the instructions packaged 
with the light kits and switches for proper assembly.

9. 

After making electrical connections, spliced conductors should 
be turned upward and pushed carefully up into the outlet box. 
The wires should be spread apart with the grounded conductor 
and the equipment-grounding conductor on one side of the 
outlet box.

10. 

All setscrews must be checked and retightened where 
necessary before installation.

WARNING:

 To reduce the risk of personal injury,

do not bend the blade brackets (also referred to as

flanges) during assembly or after installation. Do not

insert objects in the path of the blades.

WARNING:

 To reduce the risk of fire or electric

shock, do not use this fan with any solid-state speed

control device.

WARNING:

 To avoid possible electrical shock,

turn the electricity off at the main fuse box before

wiring. If you feel you do not have enough electrical

wiring knowledge or experience, contact a licensed 

electrician.

WARNING:

 Electrical diagrams are for reference

only. Optional use of any light kit shall be UL-listed

and marked suitable for use with this fan.

WARNING:

 To reduce the risk of fire or electric

shock, “this fan should only be used with fan speed 

control part no. MR140A manufactured by Satellite 

Industrial Co., LTD”

Safety Information

Table of Contents

CAUTION:

 To reduce the risk of personal injury,

use only the screws provided with the outlet box.

READ AND SAVE THESE INSTRUCTIONS.

CAUTION:

 Changes or modifications not expressly 

approved by the party responsible for compliance 

could void the user’s authority to operate the 

equipment.

CAUTION:

 Do NOT use this fan with a dimmer switch 

or wall control. Using a dimmer switch or wall control 

will damage the fan.

WARNING:

 To reduce the risk of electric shock, this 

fan must be installed with an isolating wall switch.

Содержание 51505

Страница 1: ...RS THANK YOU We appreciate the trust and confidence you have placed in Home Decorators Collection through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Home Decorators Collection Item 1001 xxx xxx Model 51505 UL Model 52...

Страница 2: ...iced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box 10 All setscrews must be checked and retightened where necessary before installation WARNING To reduce the risk of personal injury do not bend the blade brackets also referred to as flang...

Страница 3: ... warranty invalid There is no other express warranty Home Decorators Collection hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow a ...

Страница 4: ...ntity AA Blade attachment screws 15 BB Decorative nut 15 Pre Installation continued HARDWARE INCLUDED NOTE Hardware not shown to actual size Part Description Quantity CC Thumb screw 4 DD Plastic wire connector 3 AA BB DD CC ...

Страница 5: ...Part Description Quantity F Blade 5 G Light kit pan with decorative cage 1 H Light kit decorative cage 1 I Glass bowl 1 J CFL bulb 23 Watt Max 1 K Receiver 1 L Remote control battery included 1 IMPORTANT This product and or components are governed by one or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending Pre Installation continued PACKA...

Страница 6: ...Use the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 lbs Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box If the canopy C touches the ball downrod assembly B then remove the decorative canopy bottom cover and turn the canopy C 180 before attaching th...

Страница 7: ... from the canopy C by loosening the two canopy screws EE located in the L shaped slots Remove and save the two canopy screws FF in the round holes This will enable you to remove the mounting bracket A Assembling the fan Loosen but do not remove the setscrew HH on the collar II on top of the fan motor assembly E Install the downrod B by inserting it into the motor collar II and turning it clockwise...

Страница 8: ...he outlet box Securely tighten the two mounting screws LL Carefully lift the fan motor assembly E up to the slide on mounting bracket A Seat the hanger ball portion of the ball downrod assembly B in the mounting bracket socket Ensure that the tab on the slide on mounting bracket A socket is properly seated in the groove in the hanger ball 1 2 WARNING To reduce the risk of fire electric shock or ot...

Страница 9: ...he battery out of the reach of children 4 Installing the receiver Position the house supply wires AAA to one side of the slide on mounting bracket A position the fan wires BBB to the opposite side Insert the narrow end of the receiver as shown flat side towards the ceiling into the slide on mounting bracket until it rests on top of the ball downrod assembly WARNING To reduce the risk of fire or el...

Страница 10: ...ence contact a licensed electrician Wiring the fan to the receiver The fan comes with 54 in lead wires for use with an extended ball downrod assembly If using the 6 in ball downrod assembly B provided you can cut the lead wires to your desired length no shorter than 13 5 in This will make extra room in the canopy C if you do not wish to cut the wires you will need to neatly wrap them Connect the f...

Страница 11: ...to lock in place Firmly tighten the two mounting screws EE Install the two mounting screws saved from Assembly Step 1 Preparing for mounting into the holes in the canopy C and tighten firmly Install the decorative canopy ring GG by aligning the ring s slots with the screws in the canopy C Rotate the ring clockwise to lock in place 8 WARNING When using the standard ball downrod mounting the tab in ...

Страница 12: ...crew NN from the black bracket below fan motor assembly E loosen but do not remove the other two screws Connect the blue wire exiting the bottom of the fan motor assembly E with the black wire from the top of the light kit pan G Connect the white wire exiting the bottom of the fan motor assembly E with the white wire from the top of the light kit pan G Push the light kit pan G up to the fan motor ...

Страница 13: ... until it stops CAUTION Make sure the power is off before attaching or removing the glass bowl WARNING Allow the glass bowl to cool completely before removing J I G Attaching the light kit decorative cage 3 Push up the light kit decorative cage H to the top light kit decorative cage pre attached to light pan G Make sure the raised nut on each bar of the top light kit cage is fit into the notch on ...

Страница 14: ...ng your comfort A Warm weather B Cool weather 1 Power ON OFF Press and release the button to turn the fan on or off Press and hold the button for 5 seconds to use the walk away time delay this will active the light for 30 seconds the light will be activated at 50 brightness 2 Fan Speed LEDs on the fan speed button will illuminate to the corresponding speed Press and release 1 time turns the fan on...

Страница 15: ... The fan wobbles Check that all blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement Repeat for each blade Any measure...

Страница 16: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet o...

Отзывы: