Rev. 1.10
14
March 02, 2020
Rev. 1.10
15
March 02, 2020
BS83A02L/BS83B04L
Ultra-Low Power Touch Key Flash MCU
BS83A02L/BS83B04L
Ultra-Low Power Touch Key Flash MCU
3. The minimum and maximum tolerance values provided in the table are only for the frequency at which
the writer trims the HIRC oscillator. After trimming at this chosen specific frequency any change in
HIRC oscillator frequency using the oscillator register control bits by the application program will give a
frequency tolerance to -20%.
Low Speed Internal Oscillator Characteristics – LIRC
Symbol
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
V
DD
Temp.
f
LIRC
LIRC Frequency
3V
-40°C~85°C
-20%
2
+20%
kHz
1.8V~5.5V -40°C~85°C
-40%
2
+40%
t
START
LIRC Start up Time
—
-40°C~85°C
—
—
100
μs
Operating Frequency Characteristic Curves
System Operating Frequency
Operating Voltage
8MHz
1.8V
~ ~
5.5V
~ ~
~ ~
2kHz
4MHz
2MHz
Note: The 2MHz or 4MHz operating frequency for the BS83B04L only.
System Start Up Time Characteristics
Ta=-40°C~85°C
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
V
DD
Conditions
t
SST
System Start-up Time
Wake-up from condition where f
SYS
is off
—
f
SYS
=f
H
~f
H
/64, f
H
=f
HIRC
—
16
—
t
HIRC
f
SYS
=f
SUB
=f
LIRC
—
2
—
t
LIRC
System Start-up Time
Wake-up from condition where f
SYS
is on
—
f
SYS
=f
H
~f
H
/64, f
H
=f
HIRC
—
2
—
t
H
f
SYS
=f
SUB
=f
LIRC
—
2
—
t
SUB
System Speed Switch Time
FAST to SLOW Mode or
SLOW to FAST Mode
— f
HIRC
switches from off → on
—
16
—
t
HIRC
t
RSTD
System Reset Delay Time
Reset Source from Power-on Reset
or LVR Hardware Reset
— RR
POR
=5V/ms
42
48
54
ms
System Reset Delay Time
Reset Source from LVRC/WDTC/RSTC
Software Reset
(5
)
—
—
System Reset Delay Time
Reset Source from WDT Overflow
—
—
14
16
18
ms
t
SRESET
Minimum Software Reset Width to Reset
—
—
45
90
120
μs
Note: 1. For the System Start-up time values, whether f
SYS
is on or off depends upon the mode type and the chosen
f
SYS
system oscillator. Details are provided in the System Operating Modes section.
2. The time units, shown by the symbols, t
HIRC
, etc., are the inverse of the corresponding frequency values as
provided in the frequency tables. For example, t
HIRC
=1/f
HIRC
, etc.