BMH08004 Operation Guide 

                                        V1.3 

 

 

BMH08004 Operation Guide 

Contents

 

Power on/off ............................................................................................................................. 2 

Power-on Display....................................................................................................................... 2 

Finger Detection Display ........................................................................................................... 2 

Switch the Display Style of Readings ......................................................................................... 2 

Setting the Menu Parameters ................................................................................................... 3 
5.1 

Switch the menu page ................................................................................................... 3 

5.2 

Set parameters .............................................................................................................. 3 

5.3 

Exit the menu ................................................................................................................ 3 

5.4 

Brightness adjustment .................................................................................................. 3 

5.5 

Set alarm (Alm).............................................................................................................. 3 

5.6 

Set beep sound (Beep) .................................................................................................. 4 

5.7 

Set the lower limit of the blood oxygen alarm .............................................................. 4 

5.8 

Set the upper/lower limit of the heart rate alarm ........................................................ 4 

5.9 

Set parameter value to increase/decrease (“+/-”) ........................................................ 5 

5.10 

Restore to factory default ............................................................................................. 5 

The display when sensor is abnormal ....................................................................................... 5 

Battery indicator ....................................................................................................................... 5 

Operating Current ..................................................................................................................... 5 

Shutdown current ..................................................................................................................... 6 

10  Specifications ............................................................................................................................ 6 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание BMH08004

Страница 1: ... 3 5 2 Set parameters 3 5 3 Exit the menu 3 5 4 Brightness adjustment 3 5 5 Set alarm Alm 3 5 6 Set beep sound Beep 4 5 7 Set the lower limit of the blood oxygen alarm 4 5 8 Set the upper lower limit of the heart rate alarm 4 5 9 Set parameter value to increase decrease 5 5 10 Restore to factory default 5 6 The display when sensor is abnormal 5 7 Battery indicator 5 8 Operating Current 5 9 Shutdow...

Страница 2: ... pulse oximeter with OLED display 1 Power on off Power on press button Power off there is no power off button this product will shut down automatically within 10 seconds after the finger leaves 2 Power on Display UI 1 UI 2 3 Finger Detection Display UI 1 UI 2 4 Switch the Display Style of Readings UI 1 ...

Страница 3: ...menu page Short press to move up down check the second item long press to switch the menu page 5 2 Set parameters Short press to move up down select the corresponding parameter long press to set the parameter 5 3 Exit the menu Short press to move up down check Exit long press to exit the setting mode 5 4 Brightness adjustment The backlight brightness adjustment is divided into 5 levels long press ...

Страница 4: ...lues When the alarm Alm is off and the beep sound Beep is on if the blood oxygen and pulse rate measurement values exceed the range there will be no tick alarm sound only the beep sound and the flash of the out of range values OFF state the beep sound is turned off 5 7 Set the lower limit of the blood oxygen alarm Short press to move to SpO2 Lo long press the setting value increases or decreases b...

Страница 5: ...ory default The on will appear in the Restore row The factory default settings are 6 The display when sensor is abnormal When Sensor error is displayed it means that the sensor is abnormal which may be caused by poor soldering of the transmitting tube or receiving tube 7 Battery indicator 2 6V full battery 3 icons 2 4V 2 6V 2 icons 2 2V 2 4V 1 icon 2 2V turned off after flashing 2 seconds 8 Operat...

Страница 6: ...xygen saturation 1 Pulse rate 1bpm PI 0 1 Accuracy Blood oxygen saturation 2 70 100 Not requested 69 Pulse rate 2bpm or 2 whichever is the largest in room temperature 1bpm or 1 whichever is the largest PI 0 1 2 0 2 2 20 1 Preset range Blood oxygen saturation 70 99 Pulse rate Upper limit 25bpm 250bpm Lower limit 25bpm 250bpm Accuracy when in weak PI Weak perfusion index When 0 5 meet the accuracy r...