background image

INSTALLATION

INSTRUCTIONS

501 E. Goetz Ave.

Santa Ana, Ca 92707

www.eholovision.com

Ph. 714-434-6904

Fax 800-362-0002

HOLOVISION

Manual Type 1.1.0.10-RF

Holovision VIO2 with Essex 265 Controller

Specifications

Access Control

Essex 5 button keypad

2 relays

5-6 users

16.5 VAC power supply included

Internal rectifier gives optional ‘’dc out’’ for strikes

For Models

101-VIO2

107-VIO2

Communication

Holovision VIO2 is a SIP enabled intercom module

developed specifically with the custom integrator in

mind. It works with Crestron RAVA/SIP and most SIP

enabled VoIP phone systems and servers.

Speaker

Microphone

PoE+ Switch 

Push Button

Li

nk

St

at

us

Po

we

r

Re

se

t

Mic +

Mic -

Spk -

Spk +

Button

Button

Gnd

NC

NO

COM

12 VDC from Relay

OFF

PoE

On

VIO

2

Everyday VoIP from Holovision

Содержание 101-VIO2

Страница 1: ...supply included Internal rectifier gives optional dc out for strikes For Models 101 VIO2 107 VIO2 Communication Holovision VIO2 is a SIP enabled intercom module developed specifically with the custom...

Страница 2: ...1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22 12 l AC Out for Strike DC out for strike 16 5 VAC MOV is recommended Gate Strike NOTE Jumper Wire is...

Страница 3: ...Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22 12 l The 265 module comes with jumpers and MOVs prewired to the l...

Страница 4: ...ch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5 No No Yes Yes o o o...

Страница 5: ...is pressed you have 2 minutes to complete Step 5 3 Press 1119 you will hear 3 beeps 4 Step 5 must be completed within 5 seconds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm ne...

Страница 6: ...for 3 reset beeps Delete Any Code Step Action Note User codes can be 3 to 8 digits Page 6 TYPE 1 1 0 10 RF 1 Enter any User Code 1 5 2 Enter 7 This will cause the relay to latch subject to the jumper...

Страница 7: ...1 8 seconds 5 1 1 1 12 seconds 5 5 1 1 4 Wait 5 seconds for 4 reset beeps Set Activation Time Of Relay 2 User codes 3 4 5 see note below Step Action Note The above 2 steps are actually setting the act...

Страница 8: ...ll ID 0 Default is CALL CRESTRON Note out of the box the CALL CRESTRON default will ring all touchpanels in the CRESTRON call group 4 Configure the Audio setiings Note RAVA Operation has been designat...

Страница 9: ...Calls Configure the powered relay and the dry contact closure Choose any 2 to 4 digit combination Note By configuring the request to exit feature you can configure for either relay 6 Once the device h...

Страница 10: ...Page 10 TYPE 1 1 0 10 RF...

Страница 11: ...Page 11 TYPE 1 1 0 10 RF...

Страница 12: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Отзывы: