ThinPrep™ 5000 Processor with AutoLoader Operator’s Manual
4.5
4
G
YNECOLOGIC
S
AMPLE
P
REPARATION
SPECIAL PRECAUTIONS
PreservCyt
™
Solution
For more information on PreservCyt Solution, refer to Chapter 3, PreservCyt™ & CytoLyt™
Solutions
.
Interfering Substances
The Clinical and Laboratory Standard Institute Guidelines (formerly NCCLS) recommend that no
lubricant be used during Pap testing.
1
ACOG recommends that care be taken not to contaminate the specimen with lubricant because this
may lead to unsatisfactory results.
2
This applies to both conventional Pap testing and liquid based
cytology.
If you are using a plastic speculum, or in instances where a lubricant must be used, take care not to
contaminate the cervix or collection devices with the lubricant. A tiny amount of lubricant may be used,
just enough to sparingly coat the speculum with a gloved finger, avoiding the tip of the speculum.
The Clinical and Laboratory Standard Institute Guidelines and ACOG recommend that you not take
a Pap during menses.
1-2
For samples to be processed on the ThinPrep 5000 processor, lubricants can adhere to the filter
membrane and may cause poor cell transfer to the slide. If its use is unavoidable, the lubricant
should be used in minimum amounts.
Handling/Disposal
Handle all chemical-containing materials carefully in accordance with safe laboratory practices. When
required by reagent composition, additional precautions are marked on the reagent containers.
After sample transfer to the PreservCyt Solution vial, the sample
should stand for at least 15 minutes before processing.
1. Papanicolaou Technique Approved Guidelines (CLSI Document GP15-A3, third edition,
2008)
2. ACOG Practice Bulletin, no. 45, August 2003
SECTION
D
Содержание ThinPrep 5000
Страница 1: ...Operator s Manual ThinPrep 5000 Processor with AutoLoader...
Страница 5: ...This page intentionally left blank...
Страница 6: ...Instructions For Use Instructions For Use...
Страница 43: ...Table of Contents Table of Contents...
Страница 48: ...1 Introduction 1 Introduction...
Страница 73: ...2 Installation 2 Installation...
Страница 82: ...3 PreservCyt and CytoLyt Solutions 3 PreservCyt and CytoLyt Solutions...
Страница 98: ...4 Gynecologic Sample Preparation 4 Gynecologic Sample Preparation...
Страница 107: ...5 Non Gynecologic Sample Preparation 5 Non Gynecologic Sample Preparation...
Страница 134: ...6 User Interface 6 User Interface...
Страница 216: ...USER INTERFACE 6 82 ThinPrep 5000 Processor with AutoLoader Operator s Manual 6 This page intentionally left blank...
Страница 217: ...7 Operating Instructions 7 Operating Instructions...
Страница 256: ...8 Maintenance 8 Maintenance...
Страница 265: ...ThinPrep 5000 Processor with AutoLoader Operator s Manual 8 9 8 MAINTENANCE Figure 8 8 Slide Waste Bin...
Страница 282: ...MAINTENANCE 8 26 ThinPrep 5000 Processor with AutoLoader Operator s Manual 8 This page intentionally left blank...
Страница 283: ...9 Troubleshooting 9 Troubleshooting...
Страница 308: ...10 Staining and Coverslipping 10 Staining and Coverslipping...
Страница 313: ...11 ThinPrep Pap Test Training Program 11 ThinPrep Pap Test Training Program...
Страница 316: ...Service Information Service Information...
Страница 319: ...Ordering Information Ordering Information...
Страница 326: ...Index Index...
Страница 345: ...Operator s Manual ThinPrep 5000 Processor with AutoLoader...