5
III.
TECHNICAL INFORMATION
3.0
PACKING LIST
3.0.1
Surgitron
®
Dual/90 IEC (IEC3A-S30-90/110 or IEC3A-S30-90/220)
3.0.2
IEC Power cord 12ft (IEC-PC110, IEC-PCEU, IEC-PCUK, or IEC-PCANZ)
3.0.3
Instruction Manual (DIM-50-65)
ACCESSORIES (See Catalog)
3.0.4
Disposable Neutral Plates 9.5 ft (IEC-NPD)
3.0.5
Dual Footswitch & Cable 12 ft (DF-FSC#)
3.0.6
Cart (H156 or H157)
3.0.7
IEC Foot Controlled Handpiece, 1/16 shaft 11 ft (IEC-HP1)
3.0.8
Bipolar Cable 12 ft (IEC-JX/B)
3.0.9
3-Button Fingerswitch Handpiece 12 ft (IEC-3FHPB)
3.0.10 Disposable 3-Button Fingerswitch Handpieces 12 ft (IEC-3FHPB/D)
3.0.11 Disposable Electrodes (DSEP40)
3.0.12 Electrode Set 1/16 Shaft (S10B)
3.0.13 Bipolar Forceps (J1)
3.1
SUPPLIER’S INFORMATION
Cynosure, LLC
5 Carlisle Road
Westford, MA 01886, USA
Tel: 888.523.2233 Fax: 978.349.6152/978.256.4888
Supplier will make the following available upon request; circuit diagrams,
component parts list, description, calibration instructions or other information
necessary to assist technical personnel. All Generators isolate their circuits
electrically from the supply mains on all poles simultaneously by using an input
power transformer. Dispose or recycle according to local regulations. Do not
dispose of this device in the unsorted municipal waste stream.
3.2
CLEANING, DISINFECTING AND STERILIZING THE UNIT AND ACCESSORIES
3.2.1
Cleaning and disinfecting the unit: Cleaning and disinfecting of the unit
should only be done with nonflammable and nonexplosive agents. Use
mild water-based detergents. Make sure that no moisture or detergents
enter the unit. If cleaning or disinfecting the unit with flammable or
explosive agents is unavoidable, these must be completely evaporated
before the Surgitron
®
Dual/EMC is switched on.
3.2.2
Handpiece and Electrodes.
Always clean and disinfect the electrodes prior to sterilization.
Tissue residue can be removed from the active electrode with a sterile
moist cloth, steel or copper wool. No scalpel, scissors or similar pointed
objects should be used for cleaning the electrodes, since they may
damage the electrode surface. Such damage increases adhesion of
tissue to the surfaces of the electrodes during use.
Disinfect and sterilize handpieces and electrodes according to the
directions supplied with them.
All autoclavable products should be routinely inspected for any wear,
breaks, or deterioration of the insulation, and should be discarded and
replaced if any of these occurrences exist.
3.2.3
The dual footswitch is a waterproof unit; it can be cleaned with regular
detergent.
ATTENTION: Alcohol must never be used to clean and disinfect the front panel