background image

FUSE

 

Œ

Use only 1 amp fuse M-205

AUTO BACKUP

 

L

During a power outage without 

a 9V battery fitted, schedules 

will still be saved in the 

permanent memory chip

 

L

Clock time (at the time of 

the power outage) will be 

retained in memory

9V BATTERY

 

Œ

We recommend fitting 

a 9V alkaline battery to 

maintain clock accuracy 

during power outage

 

Œ

This battery should 

be replaced annually

 

L

When connected to 24V 

power pack, the unit will read 

FAULTY BATTERY

 if the 9V 

battery is low or not connected

POWER SUPPLY

This unit runs off a 240V 

50Hz single phase outlet, 

drawing 30W at 240V AC

 

L

Internal transformer:

 

Reduces 240V AC to extra low 

voltage supply of 24V AC

 

L

Fully compliant with 

AS/NZS 61558-2-6

 

L

1.25 amp low energy, high 

efficiency toroidal transformer 

for long life performance

 

L

Input:

 24V AC 50/60Hz

 

L

Output:

 Max 1 amp

 

L

To stations:

 

24V AC 50/60Hz. 0.5 amp max 

(up to 2 valves per station)

 

L

To master/pump: 

24V AC 0.25, amp max

 

L

Transformer and fuse capacity 

must be compatible with 

output requirements

 

Œ

Overload protection:

 

Standard 20mm 1 amp fuse with 

faulty station skip function

 

Œ

Output circuits should be 

installed and protected in 

accordance with wiring rules

ELECTRICAL CONNECTION

 

Œ

Installation must be carried 

out in accordance with these 

instructions and all Local, 

State and Federal codes

 

Œ

Disconnect all 240V AC 

power before commencing 

any field wiring or solenoid 

valve connection

FIELD WIRING

 

L

Hint:

 Strip approx. 6mm 

of insulation and place this 

under the loosened screw, 

tighten gently and check 

the cable is firmly held

 

Œ

A maximum of 2 solenoid valves 

can be run off each output

i.  Connect one cable from the 

terminals to each solenoid valve

ii.  Complete the circuit by 

looping

 a common cable to 

all valves and connecting to 

the COMMON (

C

) terminal

9V

ALKALINE

BATTERY

4

6

M

C

1 2 3

2

M

4 5 6 7 8

1

3

5

7

8

C

OFF

ON

SET

 WAT

ERING DURATI

ON

 PE

ST

AT

IO

N

2

1

3

4

5

6

7

8

RUN

SET CLOCK

OFF

WATER SAVER %

SYSTEM TEST

RUN A START

SET START TIME

SET DAY

START

A

B

C

24V AC

RESETTING THE UNIT

i.  Turn the 

MAIN DIAL

 to 

OFF

ii.  When the display reads 

ALL OFF

, press   until the 

display reads 

CLR ALL

iii.  Press   until the display 

reads 

ALL OFF

 again

 

Œ

All data will be erased 

from the system

STN / VALVE 1 LOCATION:

STN / VALVE 3 LOCATION:

STN / VALVE 5 LOCATION:

STN / VALVE 7 LOCATION:

STN / VALVE 2 LOCATION:

STN / VALVE 4 LOCATION:

STN / VALVE 6 LOCATION:

STN / VALVE 8 LOCATION:

Auto Watering Setup

Initial Setup

Additional Features

Auto Watering

SOLENOID 

VALVES

MASTER

COMMON

1

Installation and Wiring

Quick Setup Guide

Our 

EzyOne X

 works like a clock, sending an electrical signal to solenoid valves located around your garden. These valves divide the system up into zones or 

STATIONS

. This helps to maintain the right amount of pressure for your sprinklers. Each solenoid is 

connected to the 

EzyOne X 

via an individual cable. To complete the electrical circuit, a 

COMMON

 wire runs from the 

EzyOne X

 to all your valves. To open a valve (or water a 

STATION

), the 

EzyOne X

 sends an electric current to lift a plunger in the solenoid coil. 

After the 

RUN TIME

 has expired, the electric current is discontinued and the valve closes. The 

EzyOne X

 will then automatically open the next valve in the sequence, continuing this way until all allocated 

STATIONS

 have been watered. In addition, the 

EzyOne X 

can have up to three different 

START

 and 

RUN TIMES

 on each station.

SET CLOCK

i.  Turn the 

MAIN DIAL

 

to 

SET CLOCK

ii.  Use   to scroll between 

minutes, hours and days

iii.  Use   or   to adjust time

 

L

Hint:

 You must have the 

current day and time set to 

begin setting your watering, 

ensuring 

AM/PM

 is correct

RUN A START SEQUENCE

i.  Turn the 

MAIN DIAL

 

to 

RUN A START

ii.  Press   to run the 

desired 

RUN TIME

 

L

Each 

STATION

 

1

 through 

8

 

will run sequentially as per 

the set watering durations

 

L

Press   to cancel all 

watering immediately

SYSTEM TEST

i.  Turn the 

MAIN DIAL

 

to 

SYSTEM TEST

ii.  Each station is pre-set for 2 

minutes. Press   to commence

iii.  Press   to scroll 

through stations

iv.  Press   to stop it any time

 

L

Hint:

 Use this to automatically 

run through all stations 

on the controller

 

L

This is ideal for checking 

the operation of your 

watering system

 

L

While the system test is running, 

use   or   to adjust test duration

MANUAL STATION WATERING

 

L

RUN TIME

 will be set 

to 

OFF

 by default

 

L

Adjust the run time 

below 1 or above 255 to 

turn the station 

OFF

i.  Press   to water this station 

immediately for the set duration

 

ii.  Press   to stop watering

MOUNTING THE UNIT

 

Œ

Position the unit in a place that 

is convenient for valve wiring 

and near a power source 

 

L

Install near a 240V AC outlet

 

L

We recommend mounting 

the unit at eye level

i.  Drive a #8 screw into the 

wall, leaving approx. 4mm 

exposed. Use a toggle bolt or 

masonry plug if necessary

ii.  Hang the unit from the 

key at the back, ensuring 

it is properly seated

iii.  Optional: Remove the terminal 

cover to add additional screws 

through the holes in the lower 

corners for extra stability

STOP ALL WATERING

1.  Turn the 

MAIN DIAL

 to 

OFF

 

L

This will hold all set watering

 

L

This is ideal during wet 

weather to suspend all 

watering until the dial is 

turned back to 

RUN

SEASONAL WATER SAVING

 

L

Watering durations can be 

adjusted proportionally by a 

percentage from 10-100%

 

L

E.g. Water 100% during Summer, 

and 40% during Autumn

i.  Turn the 

MAIN DIAL

 to 

WATER SAVER %

ii.  Use   or   to adjust the 

WATER SAVER %

 shown on the 

display in 10% increments

5

SET WATERING DURATION PER STATION

i.  Use the 

MAIN DIAL

 to select 

STATION

 from 

1

 to 

8

ii.  Adjust the 

RUN TIME 

using   or 

SET DAY

i.  Turn the 

MAIN DIAL

 to 

SET DAY

ii.  Use   to scroll through 

MON

 to 

SUN

iii.  Use   or   toggle each day 

ON

 or 

OFF 

as indicated by 

 

L

Hint:

 All days 

MON

 to 

SUN

 

will be set to 

ON 

by default 

4

SET START TIME

i.  Turn the 

MAIN DIAL

 to 

SET START TIME

ii.  Use   or   to adjust time, 

ensuring 

AM/PM

 is correct 

iii.  Use   to scroll between 

minutes and hours

 

L

Press   to delete a start time

 

L

Hint:

 Each station will water a 

full 

RUN TIME

 and then stop, 

then the next station will run in 

sequence, one after the other

3

2

CHOOSE A START SEQUENCE

i.  Set the 

SLIDER SWITCH

 

to 

START A

 

L

Hint:

 

START B

 and 

C

 are 

only required if multiple 

times are needed per 

station, on different days

9V

ALKALINE

BATTERY

4

6

M

C

1 2 3

2

M

4 5 6 7 8

1

3

5

7

8

C

OFF

ON

SET

 WAT

ERING DURATI

ON

 PE

ST

AT

IO

N

2

1

3

4

5

6

7

8

RUN

SET CLOCK

OFF

WATER SAVER %

SYSTEM TEST

RUN A START

SET START TIME

SET DAY

START

A

B

C

24V AC

SLIDER SWITCH

RUN

 

L

Leave the 

MAIN DIAL

 on 

RUN 

to automatically water 

as per set schedules