Holland Green Science 10301001 Скачать руководство пользователя страница 7

 

 

User Manual 

 

Version 1.0                                                                                                                                  7 
 

II. 

Safety      

 
 

 IMPORTANT Safety Items to be Observed. 

 

 
 

Safety Warnings 

 

     ! DANGER (may cause serious damage to property and or casualties) 

1.  Please carefully read this User Manual prior to operating the instrument and observe the 

instructions on safe operation. 

2.  The power source must be grounded reliably and away from any sources of 

electromagnetic interference. 

3.  Confirm that the voltage and frequency of the power supply matches the specified 

voltage and frequency specified prior to use. 

4.  The instrument should be operated on an independent power outlet. 
5.  Do not allow the instrument to be plugged in or unplugged whilst the power switch is in 

the on position. 

6.  Do not modify the power cord. 
7.  The working environment must be free of any flammable, explosive, volatile or corrosive 

substances. 

8.  The  instrument  is  deenergised  only  when  the  power  cable  is  disconnected  from  the 

power source. 

9.  This instrument is for indoor use only. 
10. The instrument should be operated in a low humidity, well ventilated dust and water free 

environment, without direct sunshine or an intense magnetic, light or heat source.  

11. Ensure that the instrument and its accessories are free of any potential defects. 
12. Ensure that the instrument is secured tightly, and only standard accessories supplied by 

the manufacturers are used with this instrument. 

 

! WARNING (may cause property damage or personal injury) 

 

13. 

Prevent water from splashing on the electrical elements of this instrument. 

14. Before  assembly,  disassembly,  cleaning  or  maintenance,  the  power  source  must  be 

disconnected. 

15. It is Prohibited to place Flammable, Explosive, Volatile or Corrosive substances into the 

Instrument. 
 

! ATTENTION (may affect operational performance or service life) 

 

 

Содержание 10301001

Страница 1: ...User Manual Version 1 0 1 10301001 10301002 Thermotita Water Bath User Manual...

Страница 2: ...ist 11 VII Installation Requirements 12 VIII Operating Instructions 13 8 1 Display introduction 13 8 2 Command Key s Introduction 13 8 3 Temperature Controller Detailed Operation 14 8 3 1 Switch On 14...

Страница 3: ...iance with the applicable manufacturer s Published User Statement Limited User Statement or Limited License if any While this manual contains certain representations of the potential dangers from the...

Страница 4: ...nufacturer or third party supplier In no event shall the Company have any obligation to make repairs replacements or corrections required in whole or in part as the result of i normal wear and tear ii...

Страница 5: ...SS FOR A SPECIFIC PURPOSE OR USE WHETHER ARISING FROM STATUTE OR OTHERWISE IN LAW OR FROM A COURSE OF DEALING OR USAGE OF TRADE THIS WARRANTY IS NOT TRANSFERABLE FROM THE ORIGINAL PURCHASER TO A SUBSE...

Страница 6: ...VING RISE TO SUCH LIABILITY OR B ONE HUNDRED THOUSAND DOLLARS 100 000 WHICHEVER IS LESS With respect to any software products incorporated in or forming a part of the Product hereunder Buyer intends a...

Страница 7: ...e explosive volatile or corrosive substances 8 The instrument is deenergised only when the power cable is disconnected from the power source 9 This instrument is for indoor use only 10 The instrument...

Страница 8: ...quired repairs Persons performing repairs on the instrument other than those selected or approved by the Company shall operate to void any warranty contained hereinabove for the product 18 The 304 Sta...

Страница 9: ...el consists of a temperature regulation knob a heating and tracking alarm indicator and a digital temperature display The temperature control uses micro computer technology thus making temperature con...

Страница 10: ...or hardware Method and or operating steps you have undertaken towards resolution Your contact details inclusive of telephone number and email address For claims under the warranty please contact your...

Страница 11: ...nt of identified damage please contact the supplier manufacturer for technical support Carefully unpack the shipping container Remove the water bath and place it onto a clean level surface bench Check...

Страница 12: ...g conditions 1 Set up only on a bench top or worktable that is dry clean and stable with a flat horizontal surface 2 Ensure the required ventilation clearance space surrounding the instrument is 30 50...

Страница 13: ...Key s Introduction A Used for setting parameters the parameter setting mode could be quit by pressing the set button for more than 3 seconds or more B Used for moving the digits of setting value inter...

Страница 14: ...sh Set the desired value hh mm by pressing the or keys It is possible to move faster between the digits by using the button 2 Confirm the set value with another press of the button NOTE The value 00 0...

Страница 15: ...ill be terminated so the samples inside the instrument will remain exposed to the internal temperature of the chamber 8 7 Delay of Heating Cycle Start 1 It is possible to set a delay hour and minutes...

Страница 16: ...bles all heating elements to protect your samples When in alarm mode a red alarm indicator will display on the screen The oven will automatically resume operation when the temperature has dropped back...

Страница 17: ...device For Example A thermometer placed inside the oven with a different measurement than the controller Please Note Laser probe measurements will be inaccurate without compensating for emissivity Re...

Страница 18: ...power supply AL Temperature range for over temperature alarm Pb Temperature offset on single point PK Temperature offset on the entire ramp PA Temperature offset of the room temperature probe Whilst t...

Страница 19: ...the electric heater The temperature control instrument is not working Replace the temperature control instrument The cyclic fan is not working Replace the fan Set Temperature Variance to the Cabinet T...

Страница 20: ...ance work commences and please use the recommended cleaning methods for this instrument When cleaning the instrument please wear applicable PPE and protective gloves Always keep the internal and exter...