background image

 

 

HP-90F 

NETWORK DIGITAL MULTIMETER 

OPERATOR’S MANUAL 

1. Overview 

The network multimeter is characterized at slim size, portable, stable performance and anti-dropping 
capacity. Using 3 1/2 digits LCD monitor with character 16mm high, they offer clear readings.    With 
overall  circuitry  design  centering  on  large-scale  IC  A/D  converters  in  conjunction  and  over-load 
protection  circuit,  the  meters  give  excellent  performance  and  exquisite  making  as  a  handy  utility 
instrument. 
The meter can be used to measure DC & AC voltage, DC & AC current, resistance, battery, positive 
diode voltage fall and audible continuity. It can be used to test network cable (RJ45) and telephone 
line (RJ11) too. 

2. Panel Layout 

 

 

 

 

 

 

 

 

 

 

 

 

① 

LCD

 display: 3 1/2 digits LCD display. 

② 

HOLD

 key: Press the “

HOLD

” key to lock display value, and the “

” sign will appear on the 

display, press it again to exit. 

③ 

TEST

 key: Switch to RJ11 or RJ45 range and connect the telephone line or network cable with 

the instrument, Press “

TEST

”, the result will show on the LCD screen. 

④ 

CDS

 sensor: The CDS sensor can reaction to the ambient brightness range, then automatically 

control the LCD backlight to lighten or go out. 

⑤ 

Rotary Switch: Use this switch to select functions and ranges. 

⑥ 

10A:

 10A Input Jack 

⑦ 

VΩ:

 

V

  Input Jack 

⑧ 

mA:

 mA and battery test Input Jack 

⑨ 

COM:

 COM Input Jack 

⑩ 

Network cable (RJ45) test Jack 

 

Telephone line (RJ11) test Jack 

 

Cover of the network test Jack 

 

Crust of meter 

 

Protective casing 

3. Safety Information 

3-1 The meters are designed according to IEC-1010 concerning electronic measuring instruments with 

an over-voltage category CAT 

 1000V & CAT 

 600V and pollution 2. 

3-2 Follow all safety and operating instructions to ensure that the meter is used safely and is kept in 

good operating condition. 

3-3 safety symbols: 

 

Important safety information, refer to the operating manual. 

 

Dangerous voltage may be presence. 

Double insulation (protection Class II) 

4. Special Cautions for Operation 

4-1 The meters can be safe only according to standard procedures when used in conjunctions with the 

supplied  test  leads.  To  replace  damaged  test  leads  with  only  the  same  model  or  same  electric 

specifications. 

4-2 To avid risk of electric shock, do not use the meters before the cover is in place. 

4-3 The range switch should be right position for the testing. 

4-4 To avoid electric shock and damaging the instruments, the input signals are forbidden to exceed 

the specified limits. 

4-5 When measuring TV set or switched power, attention should be paid to the possible pulses that 

may bring destruction to the circuit. 

4-6 Range switch position is forbidden to be changed at random during measurement. 

4-7 Take caution against shock in the course of measuring voltage higher than DC 60V & AC 30V. 

4-8 Please do not remove the network test cover while not test the network, avoiding a risk of electric 

shock. 

4-9 Protection fuse should be replaced only with same type and same specification. 

4-10 After operation is finished, set function switch at OFF range to save battery power. 

4-11 If the meter is without usage for long time, take out battery to avoid damage by battery leakage. 

5. GENERAL SPECIFICATIONS 

5-1 Max Voltage between input terminal and Earth Ground: CAT 

 1000V & CAT 

 600V. 

5-2 Over-range Indication: display “1” or “-1” for the significant digit. 
5-3 Automatic display of negative polarity “-” . 
5-4 Low Battery Indication: “

” displayed. 

5-5 Data hold Indication: “

” displayed. 

5-6 Network cable (RJ45) test Indication: “

” displayed. 

5-7 Telephone line (RJ11) test Indication: “

” displayed. 

5-8 Display: 3 1/2 digit LCD with a max. reading of 1999. 
5-9 Manual range control 
5-10 Auto LCD backlight 
5-11 Fuse protection: 200mA/500V & 10A/500V Fast Fuse 
5-12 Power supply: 9V battery (6F22 or NEDA 1604) 
5-13 Operating Temp. : 0

 to 40

 (relative humidity <85%) 

5-14 Storage Temp. : -10

 to 50

 (relative humidity <85%) 

5-15 Guaranteed precision Temp. : 23± 5

 (relative humidity <70%) 

5-16 Dimension: 180x88x51mm 
5-17 Weight: approx. 320g (including battery) 

6. Testing Specifications

 

Accuracy is specified for a period of year after calibration and at 18

 to 28

 (64

 to 82

with relative humidity to 70%. 

6-1 DC Voltage

 

Range 

Resolution 

Accuracy 

200mV 

0.1mV 

± (0.5% of rdg + 2 digits) 

2V 

1mV 

20V 

10mV 

200V 

100mV 

1000V 

1V 

± (0.8% of rdg + 2 digits) 

-- Impedance: 10MΩ 
-- Overload protection: 1000V DC or 750V AC rms 

6-2 AC Voltage 

Range 

Resolution 

Accuracy 

2V 

1mV 

± (1.0% of rdg + 2 digits) 

20V 

10mV 

200V 

100mV 

750V 

1V 

± (1.2% of rdg + 3 digits) 

-- Impedance: 10MΩ (2V range is 1MΩ) 
-- Overload protection: 1000V DC or 750 AC rms 
-- Frequency Range: 40 to 400Hz 
-- Response: average, calibrated in rms of sine wave 

6-3 DC Current 

Range 

Resolution 

Accuracy 

200μA 

0.1μA 

± (1.2% of rdg + 2 digits) 

2mA 

1μA 

20mA 

10μA 

200mA 

100μA 

10A 

10mA 

± (2.0% of rdg + 3 digits) 

-- Overload protection: 200mA/500V & 10A/500V Fast Fuse 
Note: 10A up to 10 seconds 

6-4 AC Current 

Range 

Resolution 

Accuracy 

2mA 

1μA 

± (1.5% of rdg + 3 digits) 

20mA 

10μA 

200mA 

100μA 

10A 

10mA 

± (2.5% of rdg + 5 digits) 

-- Overload protection: 200mA/500V & 10A/500V Fast Fuse 

Note: 10A up to 10 seconds 

-- Frequency Range: 40 to 400Hz 
-- Response: average, calibrated in rms of sine wave 

6-5 Resistance 

Range 

Resolution 

Accuracy 

200Ω 

0.1Ω 

± (1.0% of rdg + 3 digits) 

2kΩ 

1Ω 

± (1.0% of rdg + 2 digits) 

20kΩ 

10Ω 

200kΩ 

100Ω 

2MΩ 

1kΩ 

20MΩ 

10kΩ 

± (1.5% of rdg + 3 digits) 

200MΩ 

100kΩ 

± (5.0% of rdg + 10 digits) 

-- Overload protection: 500V DC or AC rms 

6-6 Diode and Audible continuity test 

Range 

Description 

Test Condition 

       

 

Display read approximately 

forward voltage of diode 

Forward DC current 

approx. 1mA 

Reversed DC voltage 

approx. 3V 

     

   

Built-in buzzer sounds if 

resistance is less than 50Ω 

Open circuit voltage 

approx. 3V 

Overload protection: 500V DC or AC rms 

6-7 Battery test 

Range 

Accuracy 

Load Resistance 

Resolution 

1.5V 

± (5.0% of rdg + 5 digits) 

Approx. 30Ω 

    10mV 

6V 

Approx. 68Ω 

9V 

Approx. 909Ω 

Overload protection: 200mA/500V Fast Fuse 

6-8 Telephone line (RJ11) test 

 Normal operation of telephone line: “

PASS

” symbol will appear on the LCD display, 

 Abnormal operation of telephone line: “

FAULT

” symbol will appear on the LCD display. 

6-9 Network cable (RJ45) test 

 Normal network cables connecting: Correct connecting symbol, such as “

1-2

” or “

3-6

” will appear 

on the LCD screen. 

  Open  circuit  of  network  cables  connecting:  Open  Circuit  of  network  cables  connecting  will  not 
display on the LCD screen. For example, if 

1-2

 network cable is open circuit, “

1-2

” will not display 

on the LCD screen. 

 Short circuit of network cables: The symbol of  short circuit of network cables will  display on the 
LCD screen. For example, if cable 

1-2

 is short circuit, “

1-2

”, “

SHO.

” will display on the LCD screen. 

 Misconnection of network cables: The symbol of misconnection of network cables will display on 
the LCD screen. For example, if cable 

1-2

 is misconnecting, “

1-2

”, “

MIS.

” will display on the LCD 

screen. 

 Reverse connection of  network cables: The symbol of reverse connection of  network cables will 
display  on  the  LCD  screen.  For  example,  if  cable 

1-2

  is  reverse  connecting,  “

1-2

”,  “

REV.

”  will 

display on the LCD screen. 

 Split pairs of network cables: The Split pairs network cables will display on the LCD screen. For 
example, if cable 

1-2

 and 

3-6

 are split pairs, “

1-2

”,“

3-6

”, “

SPL.

” will display on the LCD screen. 

 Shield of  network cable: If  shield of  network cable is  normal, “

SHIELD

”  will display on the LCD 

screen, if shield of network cable is open circuit or not excite, “

SHIELD

” will not display on the LCD 

Screen. 

Отзывы: