Introduction 

Compact, rugged and easy to use. Just aim and push the 
button,  read  current  surface  temperatures  in  less  than a 
second.  Safely  measure  surface  temperatures  of  hot, 
hazardous or hard-to-reach objects without contact. 
 

 

 

 

 

 

 

 

 

 

 

How it works 
Infrared  thermometer  measures  the  surface  temperature 
of  an  object.  The  unit’s  optics  sense  emitted,  reflected, 
and transmitted energy which is collect and focused onto 
a  detector.  The  unit’s  electronics  transmitted  energy 
which  is  display  on  the  unit.  For  increased  ease  and 
accuracy  the  laser  pointer  makes  aiming  even  more 
precise. 

Cautions 

Infrared  thermometer  should  be  protected  for  the 
following: 
--EMF(electro-magnetic  fields)  from  arc  welders, 
induction heaters. 
--Thermal  shock(cause  by  large  or  abrupt  ambient 
temperature  changes  allow  1  hours  for  unit  to  stabilize 
before use). 
--Do  not  leave  the  unit  on  or  near  objects  of  high 
temperature. 

 

 

 

 

 

 

 

 

 

Warning 

Do  not  point  laser  at  eye  or  indirectly  off  reflective 
surfaces. 
1.

 

When take measurement, point thermometer toward 
the  object  to  be  measured  and  hold  the  yellow 
trigger.  The  object  under  test  should  be  large  than 
the  spot  size  calculated  by  the  field  of  view 
diagram. 

2.

 

Distance 

  spot  size:  As  the  distance  from  the 

object  increase,  the  spot  size  of  measuring  area 
becomes large. 

 

 

 

 

 

 

 

 

 

 

3.

 

Field of view: Make sure the target is larger than the 
unit’s  spot  size.  The  smaller  the  target  the  close 
measure  distance.  When  accuracy  is  critical,  make 
sure  the target  is at  least  twice as  large as  the spot 
size. 

4.

 

Emissivity:  Most  organic  materials  and  painted  or 
oxidized surfaces have an emissivity of 0.95(pre-set 
in  the  unit).  Inaccurate  readings  will  result  from 
measuring  shiny  or  polished  metal  surfaces.  To 
compensate, cover the surface to be measured with 
masking tape or flat black paint. Measure the tape or 
painted  surface  when  the  tape  or  painted  reach  the 
same temperature as the material underneath. 