![HOKUYO AUTOMATIC UAM-05LP Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/hokuyo-automatic/uam-05lp/uam-05lp_user-manual_2145000066.webp)
Document No: C-61-00003-3
Figure 5-7 Parallel installation
5.3 High reflective background
Measured value will be longer than the actual distance of the object due to high reflective background
leading to wrong OSSD output. When high reflective background cannot be avoided in the working
environment, additional distance of 200mm is necessary while configuring the protection and warning zones
(Figure 5-8). Refer to UAM’s specification for the required distance tolerance.
*
Additional distance : Required additional distance when operating UAM under high reflective background
Figure 5-8
Additional distance in high reflective background
Shielding material should be opaque.