5.2 Mutual interference
Cautions are required while using two or more units of UAM or identical products as pulsed laser signal
from one another could lead to false detection. Figures below show the installation method for avoiding the
mutual interference.
a)
Changing the height of installation
Install at different heights to separate the mutual detection plane by 5 degrees or more.
Figure 5-2 Opposite facing installation
Figure 5-3 Parallel installation