6 - SETUP
(See 5.2 - Menu access diagram)
The Setup frame provides the user with numerous options for setting the machine according to his needs.
All the settings remain unaltered even when the machine is switched off.
The enabled buttons are :
HOME
STOP
: return to previous window
MENU
:
go to measurement frame;
from
to
: to select parameter
6.1 - LANGUAGE
Permits selecting the language to be used for displaying description and diagnostic messages relating to
machine operation.
6.2 - UNBALANCE MEASUREMENT UNIT
Imbalances can be expressed in either grams or ounces
6.3 - UNBALANCE DISPLAY THRESHOLD
This is the unbalance threshold under which, at the end of the spin the message "OK" appears on the screen
instead of the unbalance value; the values which can be set vary according to the selected measurement unit.
6.4 - UNBALANCE DISPLAY STEP
Represents the unbalance display step and varies according to the selected measurement unit. The choice 5
g" (1/4 oz) enables the display of the correction values on the two sidewalls so as to bring the value of static
unbalance to 0 (theoretical). This function is best set when the machine is used in standard mode as the balancing
quality is improved. The computer performs a complex calculation whereby the static residue is cancelled by
changing the value and position of the fixed value counterweights 5 grams at a time (1/4 ounces).
6.5 - SPIN WITH COVER CLOSED
By selecting "ON", the automatic spin start is engaged when the cover is closed.
6.6 - SCREEN-SAVER TIME
When the machine has not been used for longer than the time set in this function, the computer automatically
returns to the initial frame. Set this time in seconds.
6.7 - VISUAL RUN-OUT CHECK
At the end of the spin, when the measured unbalance values re-appear on the screen, the cover can be opened
to visually check the wheel run-out while the wheel gradually loses speed. If, on the other hand, the cover is left
closed, the machine completes normal positioning.
6.8 - ACOUSTIC ALARM
By selecting "ON", an acoustic alarm is enabled (beep) in the following cases:
- whenever a button is pressed;
- when dimensions are acquired automatically;
- when the correct weight application angular position is achieved, in the measurement frame;
- when the correct weight application angular position is achieved, in the position repeater.
6.9 - SETTING THE CLOCK
For correctly setting the time. Follow the instructions shown on the screen.