BA / ETL duolift MTE 3000 – 94 12 554
7
6.
Foundation
The duolift MTE 3000 is designed to be installed
without a base frame, therefore fastening to the gro-
und/foundation is most important. The entire load
(weight of vehicle and dead weight of the columns) is
transferred to the foundation through heavy-duty an-
chor bolts.
Before installing the lift it is always necessary to en-
sure that the floor is adequate (see Fig. 2 and Fig.
3).
When installing the lift on an upper floor, the floor's
suitability must be verified by a construction engineer
or another competent person.
The lift is normally mounted on small "base plates",
however if the floor quality is inadequate the lift can
be mounted on a base frame (available as an optio-
nal extra).
It is essential that the heavy duty anchor bolts pe-
netrate to their full working depth as shown in Fig. 3
to ensure sufficient safety for persons working under
the lift. (Heavy duty anchor bolts are not supplied
with the lift).
For the correct length of the active part of the anchor
bolt refer to Fig. 2. Drill size and tightening torque
must be in accordance with the bolt manufacturer's
instructions.
To achieve a perfect installation, the floor should be a
flat and level concrete floor (min. BN25, frost-proof)
designed to take a load of at least 200 kN/m
2
. If bol-
ted to an existing reinforced concrete floor individual
checks are required.
7.
Installation and initial operation
7.1 Mechanical assembly
•
First bolt the lifting columns to the base plates
(using hexagon head set screw M16x40 with
washer). Then place them in position. The di-
stances between the columns/base plates are
shown in Fig. 4.
•
The base frame (optional extra) should be placed
in position, if required, and fixed to the floor with
M12 anchor bolts. Tightening torque and penetra-
tion into ground must be according to manufactu-
rer's specifications.
Fig. 2 Base plate
Fig. 3
Floor anchor bolt
1 Base plate of lift
2 Screed or other floor covering resistant to compression
3 Reinforced concrete (concrete quality B25)
4 Anchor bolt HSL-G-TZ M 16/100
Reinforcement:
BST 500/550 RK top/bottom
Steel fabric min Q 188
Fig. 4
Distance between columns/base plates
The base frame must be positioned on a flat load be-
aring surface.
•
When using the base frame the M16x45 bolts
that are screwed into the base frame must be
Содержание duolift MTE 3000
Страница 1: ...duolift MTE 3000 Betriebsanleitung Ersatzteilliste Zwei Säulen Hebebühne ...
Страница 6: ...6 BA ETL duolift MTE 3000 9412 554 09 98 Bild 1 Maße ...
Страница 11: ...BA ETL duolift MTE 3000 94 12 554 11 Bild 6 Klemmplan Steuerplatine ...
Страница 17: ...BA ETL duolift MTE 3000 94 12 554 17 Bild 12 Tragmutter Verschleißmarke ...
Страница 18: ...BA ETL duolift MTE 3000 94 12 554 18 Bild 13 Prinzip der Wiederauffahrsicherung ...
Страница 20: ......
Страница 21: ...BA ETL duolift MTE 3000 94 12 554 21 Bild 14 Ersatzteilübersicht ...
Страница 23: ...BA ETL duolift MTE 3000 94 12 554 23 ...
Страница 24: ...duolift MTE 3000 Operation manual Spare parts list Two post lift ...
Страница 29: ...6 BA ETL duolift MTE 3000 9412 554 09 98 Fig 1 Dimensions ...
Страница 34: ...BA ETL duolift MTE 3000 94 12 554 11 Fig 6 Connection diagram controller board ...
Страница 40: ...BA ETL duolift MTE 3000 94 12 554 17 Fig 12 Lifting nut wear point ...
Страница 41: ...BA ETL duolift MTE 3000 94 12 554 18 Fig 13 Operating principle of safety lock ...
Страница 43: ...BA ETL duolift MTE 3000 94 12 554 20 Fig 14 View of spare parts ...