26
Section 6: Specifications
Table 6: Dripmaster EDD-4SH specifications
Power requirements
115 VAC, 60 Hz, 10 VA, or 24 V DC/AC
220 VAC, 50 Hz, 10 VA or 24 V DC/AC
Normal mode preset drip rates (pump on)
10, 12, 14, 16, 18, 20, 22, 24, 26, 28 dpm
Pre-lube mode drip rate (pump off)
2 dpm
Drip volume
50 drops per 1 cc
PULSE relay contact
35 VDC – 0.5 A
O.K. relay contact
250 VAC – 10 A AC1
110 VAC – 10 A AC1
110 VDC – 0.3 A
30 VDC – 10 A
L.L. (low oil level) relay contact
125 VAC – 0.5 A
110 VDC – 0.2 A
24 VDC – 1 A
S.B. (
Normal/Pre-lube
mode control)
24 V DC/AC
Duty cycle
60 secs count
6 secs freeze
Drip stabilizing tolerance
x when SW 18 is UP
x to x+1 when SW 18 is DOWN
(where x is the pre-selected drip rate)
Oil on/off solenoid
24 VDC
24 VAC (optional)
Oil inlet/outlet
Male thread ¼" BSP
Dimensions (W x H x D)
10.24 x 11.02 x 3.54 inches (260 x 280 x 90 mm)
Weight
11 lbs (5 kg)
All specifications shown are subject to change.
Table 7: Oil volume fed to line shaft
Drip Rate (dpm)
2
10
12
14
16
18
20
22
24
26
28
Volume:
ml/
hour 2.4 12 14.4 16.8 19.2 21.6 24 26.4 28.8 31.2 33.6
Volume:
gal./
day 0.015 0.076 0.090 0.105 0.12 0.135 0.15 0.165 0.18 0.195 0.21
Volume figures are based on a Dripmaster drop volume of 50 drips = 1 ml.