20
GB
Fig. 1
Structure of steam generator
9
11
1
2
4
6
5
8
7
12
1
1
10
1
3
1 - Insertion points for installation pins
2 - Controller board
3 - Glands for sensor cables and lighting
4 - Peristaltic pump for descaling liquid
5 - Water supply G3/4"
6 - Water drainage from generator
22
7 - Steam outlet (6kW
22; 12 i 21kW
35)
8 - Safety over
fl
ow
9 - Control panel
10 - Thermal switch
11 - Fastening screws
12 - Water level sensor
Fig. 2
Hydraulic system and temperature sensor in the steam bath
7
8
5
4
3
1
6
2
3%
200
~1000
11
9
10
11
10
9
1 – Steam generator
2 - Pump for descaling liquid
3 – Aroma dispensing pump
4 - Aroma dispensing valve
5 –
Descaling liquid tank
6
-
Drainage of water DN 50 Drain
trap (local)
7 - Aroma tank
8 – Basket for utensils
9
-
Power supply 1x230V or 3x400 V,
50 / 60 Hz (see Table 03.01)
10 - Temperature sensor
11 - Steam bath lighting (low voltage)