Flue gas analyzer

HODAKATEST

 

HT-1300Z

User manual

Содержание HODAKATEST HT-1300Z

Страница 1: ...COhigh typeD O2 CO NO NO2 typeE O2 NO NO2 SO2 HODAKA CO LTD 1 6 17 Takadono Asahiku Osaka Japan 535 0031 TEL 81 0 6 6922 5501 FAX 81 0 6 6922 5895 Email info hodaka inc co jp ver 180801 URL http www hodaka inc co jp Flue gas analyzer HODAKATEST HT 1300Z User manual ...

Страница 2: ...Connection port 7 9 Calculation 27 4 3 Key board 10 Specification 28 5 POWER SUPPLY 8 11 Condensate trap 30 6 STORAGE 6 1 Operating and storage temperature 12 Message 31 6 2 Long term non operating and storage 13 Guarantee 31 7 Measurement preparation 7 1 Probe connecting 8 OPERATION 9 8 1 Operation Basic 8 1 1 Charge 8 1 2 Switch ON the unit 10 8 1 3 Start the measurement 8 1 4 Switch OFF the uni...

Страница 3: ...user manual is an important part of the scope of supply and assures not only the correct operation and use of the analyzer but also the safety of the user and the environment Several marks are used in this manual Below are the meaning of each marks High risk of decease or injure Risk of decease or injure Risk of injure or possessions have damage Advice 2 3 Sensor Sensor life is very much influence...

Страница 4: ...e The indicated range of temperature of the probe is not to be exceeded as the probe temperature sensory mechanism and sensor could be destroyed The analyzer must not be dropped The magnet is used at the rare housing Therefore any precision machine should not be settled near the analyzer After measurement purge by fresh air and dry condensate inside analyzer Also incase filter is wet or dirty plea...

Страница 5: ...ng and storage temperature 7 Measurement preparation 7 1 Probe connecting Ambient air temp is used to calculate efficiency and losses etc In case this ambient air temp sensor is not selected main unit views the temperature value which is measured by flue gas temp sensor of probe as the ambient air temp Operating 0 C 45 C Storage 20 C 50 C 6 2 Long term non operating and storage Even switch is off ...

Страница 6: ...setting is finished calibration mark will be disappeared In case you use same Program No Fuel CO limit O2 calculation value as previous time is it possible to movie to measurement window by means of only press F1key 8 2 2 Measurement program selection 3 8 1 2 Switch on the unit Switch on the unit 8 3 1 Stored data menu 8 4 1 Setting menu Next window No press OK key after approx 8 sec the unit entr...

Страница 7: ... m3 NO Nitrogen monoxide ppm mg m 3 mg kWh mg MJ 1 Carbon monoxide ppm mg m 3 mg kWh mg MJ 1 CO Carbon monoxide CO 0 CO reference O2 O2 0 ppm Indication Items Unit O2 Oxygen Selected measurement program Fuel and O2 calculation value Current page switch 4items indication 8 items indication CO2 Carbon dioxide CO ExAir 8 2 5 Draft measurement T Gas Combustion gas temperature page change measurement s...

Страница 8: ...up every 500 ppm 3000ppm 10000ppm If CO concentration exceeds threshold value purge pump starts work and expose ambient air for protect sensor Incase the unit have purge pump 8 2 1 Measurement menu F1 Measurement F2 Stored data menu F3 Setting menu 8 2 2 2 CO cut off Select one program among program1 program5 then enter to 8 2 2 3 Fuel selection It is possible to store the setting of 8 2 2 2 CO li...

Страница 9: ...asurement window 15 16 During zero setting the color of the letter F3key zero turns to black Slowly insert probe to flue gas then temperature sensor will catch the highest temperature Once the probe left the highest temperature alarm sound becomes to short Turn probe back to the former position and fix the probe by the cone Max 115 The most highest temp Act 106 Current temp which is measured by te...

Страница 10: ...indow Stop the zero setting of pressure sensor Back to above window 17 18 Stored No is shown as left window You can write over it but original data will be deleted In case boiler temp smoke no is yes on 8 4 1 1 Device setting left window is indicated Oily is indicated in case smoke no is Yes Max 4 points of pressure can be measured Connect a hose to ΔP connection port For differential pressure mea...

Страница 11: ...ion mark 4 lines 8 lines indication change Chang page Next window Print out Next window boiler temperature soot no Oily is appeared if you select YES at Smoke no Move to stored sites selection window 19 20 In case you do not press Okay after about 8 seconds it automatically move to next window Switch it measurement menu window During zero setting you can set other parameters and see stored data Le...

Страница 12: ...port Yes Not export No 8 3 1 3 Delete all sites Move cursor Select Delete sites confirm it Next window During data transmission display becomes like left display After the data transmission stored data menu Delete the sites Yes Not delete the sites No After delete not delete move to previous window 21 22 If Import site data is opened by mistake left window will be shown Press F2key No and wait unt...

Страница 13: ...to above window Back to above window change number Move cursor Back to above window 23 24 Setting items Range Description LCD contrast 14 7 Adjust LCD contrast Back llight 0 30minuts Set the lighting time of back light Set the brightness of back light Printer Unchangeable Signal On Off Key sound On Off 4 8 Set the measurement item quantity on display Page 1 2 3 Set the measurement window pages Yes...

Страница 14: ...opened by mistake left window will be shown Press F3 key date month y date month year hour minutes seconds Fuel 13A 6C LPG Kerosene Heavy oil A Heavy oil C Pellets CO2 max value O2ref Measurement items T Gas O2 CO2 CO ppm CO NO ppm NO2 ppm SO2 ppm NOx ppm T Air Exc Air Losses Effic CO 0 ppm COrefO2 ppm CO mg m3 NO 0 ppm NOrefO2 ppm NO mg m3 NOx 0 ppm NOxrefO2 ppm NOx NO2 mg m3 SO2 0 ppm SO2 refO2 ...

Страница 15: ... by user 13A 12 04 10 95 12 2 57 Excess air 1 00 9 99 6C 4 89 4 08 13 1 77 Losses 0 99 9 LPG 25 9 23 9 13 8 77 0 100 kerosene 12 15 11 37 15 1 111 Dew point 0 100 Light oil 11 9 11 15 15 4 111 mg m3 Heavy A 11 37 10 68 15 8 111 Heavy C 10 88 10 25 16 111 Pellet 4 63 4 63 20 3 0 27 28 9750 4200 GO Theoretical flue gas volume AO Theoretical air volume Calp Lowe calorific value CO2max CO2 Max value o...

Страница 16: ...eight 3kg Measurement software HT 2074 Online View 2000 Windows7 8 1 10 with RS232 cable Measurement software HT 2084 Blue tooth module 7 HT 1833 For measurement software Infrared printer HT 1610 1 x printer roll paper 4 x AAbattery Bad sample Roll paper for infrared printer HT 1636 5 Rolls Be sure that the O ring proerly put the O ring is twisted slit of the joint Bad fitting may cause leakage 1 ...

Страница 17: ...ection Reason 2 The unit has been stored without operation Solution Reason 3 Zero setting have done in flue gas Solution Do zero setting again in ambient air 13 Guarantee 31 32 HODAKA CO LTD 1 6 17 Asahiku Takadono Osaka Japan 535 0031 TEL 81 0 6 6922 5501 FAX 81 0 6 6923 1617 Traceability certification can be issued at HODAKA Additional cost will be required Charge battery and re start Left windo...