Hobo S-WCG-M003 Скачать руководство пользователя страница 1

Ultrasonic Wind Speed and Direction Smart Sensor  
(S-WCG-M003) Manual 

22408-B 

The Ultrasonic Wind Speed and Direction smart sensor is designed to work with HOBO® 
stations and is powered by its own built-in solar panel. The smart sensor has a plug-in modular 
connector that allows it to be added easily to a HOBO station. All sensor parameters are stored 
inside the smart sensor, which automatically communicates configuration information to the 
logger without the need for any programming or extensive setup. 

Note:

 This sensor has been 

modified to work with Onset station loggers only. 

Specifications 

 

Wind Speed/Gust 

Wind Direction 

Measurement Range 

0 to 41.16 m/s (0 to 92.07 mph) 

0 to 359 degrees 

Accuracy 

±0.8 m/s (1.79 mph) or ±4% of 
reading, whichever is greater 

0.2 to 3 m/s (0.44–6.7 mph):  
±4 degrees  
>3 m/s (6.7 mph): ±2 degrees 

Resolution 

0.4 m/s (0.89 mph) 

1 degrees (0 to 359 degrees) 

Measurement Definition 

Wind speed readings are taken 
every three seconds for the 
duration of the logging interval 

Wind speed

: Average speed for 

the entire logging interval 

Gust speed:

 The highest three-

second wind recorded during 
the logging interval 
See 

Measurement Operation

Unit vector averaging used; 
vector components for each 
wind measurement are 
calculated every three seconds 
for duration of logging interval 
(see 

Measurement Operation

Operating Temperature Range 
Without Icing 

-15°C to 55°C (5°F to 131°F) 

Environmental Rating 

Weatherproof 

Housing 

Polyacetal 

Dimensions 

Sensor length: 380 mm (14.96 inches)  
Sensor head diameter: 60 mm (2.36 inches) 
Sensor rod diameter: 16 mm (0.63 inches) 

Weight 

200 g (7 oz) 

Power Supply 

Photovoltaic panel, LIFEP04 3.2 V -600 mAh battery 

Bits per Sample 

8 for each channel, 24 total 

Number of Data Channels* 

Measurement Averaging 
Option 

Automatic averaging (see 

Measurement Operation

Cable Length Available 

3 m (9.8 ft) 

Length of Smart Sensor 
Network Cable* 

0.5 m (1.6 ft) 

 

The CE Marking identifies this product as complying with all relevant 
directives in the European Union (EU). 

*  A single HOBO station can accommodate 15 data channels and up to 100 m (328 ft) of smart sensor cable (the digital 

communications portion of the sensor cables). 

 

 

Ultrasonic Wind Speed & 
Direction Smart Sensor 

S-WCG-M003 

Items included: 

 

North alignment tool 

 

U-bolts with hex nuts, 
brackets, spacers, and lock 
nuts for mounting on a 
mast or cross arm 

Items required: 

 

Phillips-head screw driver 

 

10 mm wrench (if 
mounting on a mast or 
cross arm) 

 

Screws and drill (if 
mounting on a vertical 
surface) 

Accessories: 

 

Grounding kit (M-GKA) 

 

Содержание S-WCG-M003

Страница 1: ...ion Unit vector averaging used vector components for each wind measurement are calculated every three seconds for duration of logging interval see Measurement Operation Operating Temperature Range Wit...

Страница 2: ...e bottom of the sensor base Loosely tighten the four screws to keep the sensor rod in place Once these steps are complete mount the sensor using the guidelines in the next section Mounting Mounting Gu...

Страница 3: ...t sensor adapters can be stacked as shown in the example below on the right Alternatively mount the smart sensor adapter to a flat surface using two screws no larger than a 6 and two washers as shown...

Страница 4: ...f the hex nut with the flat end facing out Place a spacer on top of the bracket as shown below Repeat for the other threaded bolt end and for both ends of the other U bolt 5 Insert both bolt assemblie...

Страница 5: ...g your GPS or a magnetic compass go to a point that is directly north of the station and at least 100 m 328 ft away from the station To determine this point move until the station is directly south of...

Страница 6: ...inaccurate results For example three measurements of 350 11 and 12 degrees which are all winds from the north averaged together would result in 126 degrees which incorrectly indicates a southeasterly...

Страница 7: ...od so that you can easily reattach the sensor head 9 Make sure the mark from step 3 is aligned with the north marking and reattach the sensor head Tighten the three screws 10 Connect the battery and i...

Отзывы: