TM-260 273 Page 16
Handler 190
SECTION 4 − OPERATION
4-1.
Controls
1
Wire Speed Control
Use control to select a wire feed speed. As
Voltage switch setting increases, wire
speed range also increases (see weld
setting label in welding power source or
Section 4-2, as applicable).
2
Power Switch
3
Voltage Switch
The higher the selected number, the
thicker the material that can be welded
(see weld setting label in welding power
source or Section 4-2, as applicable). Do
not switch under load.
.
Switch must “click” into detent
position.
4
Gun Trigger Receptacle
5
Trigger Switch
When pressed, energized wire feeds and
shielding gas flows.
Ref. 248 840-A / Ref. 246 668-A
5
2
3
1
4
Содержание H100S4-10
Страница 19: ...TM 260 273 Page 17 Handler 190 4 2 Weld Parameter Chart For 230 VAC Model 248 827 B ...
Страница 32: ...TM 260 273 Page 30 Handler 190 Notes ...
Страница 35: ...TM 260 273 Page 33 Handler 190 248 830 A ...
Страница 37: ...TM 260 273 Page 35 Handler 190 248 831 A ...
Страница 40: ...TM 260 273 Page 38 Handler 190 Notes ...