6(&7,21   6$)(7< 35(&$87,216  5($' %()25( 86,1*

  

   

Means Warning! Watch Out! There are possible

hazards with this procedure! The possible hazards are

shown in the adjoining symbols.

?      

0HDQV ´1RWHµ QRW VDIHW\ UHODWHG

This group of symbols means Warning! Watch Out! possible

ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.

Consult symbols and related instructions below for necessary

actions to avoid the hazards.

    

?          

             

          

              

         

              ! 

   

? " #           

     

? $          

$ ', - .//!

Touching live electrical parts can cause fatal

shocks or severe burns. The electrode and work

circuit is electrically live whenever the output is on.

The input power circuit and machine internal

circuits are also live when power is on. In semiautomatic or

automatic wire welding, the wire, wire reel, drive roll housing, and all

metal partstouchingthewelding wire areelectrically live. Incorrectly

installed or improperly grounded equipment is a hazard.

-

Do not touch live electrical parts.

-

Wear dry, hole-free insulating gloves and body protection.

-

Insulate yourself from work and ground using dry insulating mats

or covers big enough to prevent any physical contact with the

work or ground.

-

DonotuseACoutputindampareas,ifmovementisconfined,orif

there is a danger of falling.

-

Use AC output ONLY if required for the welding process.

-

If AC output is required, use remote output control if present on

unit.

-

Disconnect input power or stop engine before installing or

servicing this equipment. Lockout/tagout input power according

to OSHA 29 CFR 1910.147 (see Safety Standards).

-

Properly install and ground this equipment according to its

Owner’s Manual and national, state, and local codes.

-

Always verify the supply ground -- check and be sure that input

power cord ground wire is properly connectedto ground terminal

in disconnect box or that cord plug is connected to a properly

grounded receptacle outlet.

-

When making input connections, attach proper grounding

conductor first -- double-check connections.

-

Frequently inspect input power cord for damage or bare wiring --

replace cord immediately if damaged -- bare wiring can kill.

-

Turn off all equipment when not in use.

-

Do notuseworn, damaged,undersized,or poorly splicedcables.

-

Do not drape cables over your body.

-

If earth grounding of the workpiece is required, ground it directly

with a separate cable.

-

Donottouchelectrodeifyouareincontactwith thework, ground,

or another electrode from a different machine.

-

Useonlywell-maintainedequipment.Repairorreplacedamaged

parts at once. Maintain unit according to manual.

-

Wear a safety harness if working above floor level.

-

Keep all panels and covers securely in place.

-

Clamp work cable with good metal-to-metal contact to workpiece

or worktable as near the weld as practical.

-

Insulatework clamp when not connectedto workpiece toprevent

contact with any metal object.

-

Do not connect more than one electrode or work cable to any

single weld output terminal.

   0$  1 -2 +*-/ 2

3 4  *!

-

Turn Off inverter, disconnect input power, and discharge input

capacitors according to instructions in Maintenance Section

before touching any parts.

Welding produces fumes and gases. Breathing

these fumes and gases can be hazardous to your

health.

)80(6 $1' *$6(6 FDQ EH KD]DUGRXV

-

Keep your head out of the fumes. Do not breathe the fumes.

-

If inside, ventilate the area and/or use exhaust at the arc to

remove welding fumes and gases.

-

If ventilation is poor, use an approved air-supplied respirator.

-

Read the Material Safety Data Sheets (MSDSs) and the

manufacturer’s instructions for metals, consumables, coatings,

cleaners, and degreasers.

-

Work in a confined space only if it is well ventilated, or while

wearing an air-supplied respirator. Always have a trained watch-

person nearby. Welding fumes and gases can displace air and

lower the oxygen level causing injury or death. Be sure the

breathing air is safe.

-

Do not weld in locations near degreasing, cleaning, or spraying

operations. The heat and rays of the arc can react with vapors to

form highly toxic and irritating gases.

-

Do not weld on coated metals, such as galvanized, lead, or

cadmium plated steel, unless the coating is removed from the

weld area, the area is well ventilated, and if necessary, while

wearing an air-supplied respirator. The coatings and any metals

containing these elements can give off toxic fumes if welded.

Содержание Beta Mig 135 P

Страница 1: ...MIG GMAW Welding HWD 0LJ 3 February 1999 Effective with serial number 135P 152345 175P 152385 2 1 5 6 0 18 0 0 1 ...

Страница 2: ......

Страница 3: ... 0 1 2 3 4 5 6 5 2 3 3 4 7 7 7 OM 194 034 ...

Страница 4: ..._con_ita 5 97 HFODUDWLRQ RI RQIRUPLW µ LFKLDUD LRQH GL RQIRUPLWj 0 5 XURSH 6 S HWD 0LJ 3 8 9 25 5 9 9 25 5 0 5 2 5 3 5 2 1 2 3 4 4 8 9 3 55 55 5 3 6 3 07 9 35 525 0 4 00 7 4 3352 8 5 3 52 53 9 5 3 52 53 3 ...

Страница 5: ...g can kill Turn off all equipment when not in use Donotuseworn damaged undersized orpoorlysplicedcables Do not drape cables over your body If earthgroundingofthe workpieceis required groundit directly with a separate cable Donottouchelectrodeifyouareincontactwiththework ground or another electrode from a different machine Useonlywell maintainedequipment Repairorreplacedamaged parts at once Maintai...

Страница 6: ...s Remove stick electrode from holder or cut off welding wire at contact tip when not in use Wear oil freeprotectivegarmentssuchasleathergloves heavy shirt cuffless trousers high shoes and a cap Removeanycombustibles suchasabutanelighterormatches from your person before doing any welding 83 6 Welding chipping wirebrushing andgrinding causesparksandflyingmetal Asweldscool they can throw off slag Wea...

Страница 7: ...grounding and shielding to minimize the possibility of interference ARC WELDING can cause interference Electromagnetic energy can interfere with sensitive electronic equipment such as computers and computer driven equipment such as robots Be sure all equipment in the welding area is electromagnetically compatible To reduce possible interference keep weld cablesas shortas possible close together an...

Страница 8: ... human health hazard However studies are still going forth and evidence continues to be examined Untilthefinalconclusionsoftheresearcharereached you may wish to minimize your exposure to electromagnetic fields when welding or cutting To reduce magnetic fields in the workplace use the following procedures 1 Keep cables close together by twisting or taping them 2 Arrange cables to one side and away ...

Страница 9: ...age of 10 minutesthatunitcan weldatrated load without overheating If unit overheats thermostat s opens output stops and cooling fan runs Wait fifteen minutes for unit to cool Reduce amperage or duty cycle before welding 6 0 15 0 OR Reduce Duty Cycle Minutes 7 7 20 duty cycle at 130 amps 50Hz 20 duty cycle at 140 amps 50 Hz 20 25 30 40 50 60 70 80 90100 35 250 200 150 100 50 6 7 8 6 6 5DWHG 2XWSXW ...

Страница 10: ...s Insertleads oneatatime through small grommet on front panel Connect female friction terminals tomatching male terminals in unit Polarity is not important Close door 4 1 2 3 1 Lead Connections For Direct Current Electrode Positive DCEP 2 Lead Connections For Direct Current Electrode Negative DCEN Always read and follow wire manufacturer s recommended po larity and see Section 3 3 Close door 1 2 8...

Страница 11: ...l 5 Regulator Flowmeter Gas Hose Connection 6 Welding Power Source Gas Hose Connection Connect customer supplied gas hose between regulator flowmeter gashoseconnection andfittingon rear of welding power source 7 Flow Adjust Typical flow rate is 20 cfh cubic feet per hour Check wire man ufacturer s recommended flow rate 8 CO Adapter Customer Sup plied 9 O Ring Customer Supplied InstalladapterwithO ...

Страница 12: ...cording to its instructions 3 Receptacle Connect plug to matching recep tacle 4 Input And Grounding Conductors Connectdirectlytolinedisconnect device if hard wiring is required 5 Line Disconnect Device See Section 3 6 76 6 4 L1 L2 230 VAC 1 18 in 457 mm of space for airflow L1 L2 1 9 87 6 4 2 3 5 0 0 1 ...

Страница 13: ...LQJ Q PSHUHV 20 25 0LQ QSXW RQGXFWRU 6L H Q FPLO 2 5 2 5 0D 5HFRPPHQGHG QSXW RQGXFWRU HQJWK Q 0HWHUV 3 3 0LQ URXQGLQJ RQGXFWRU 6L H Q FPLO 2 5 2 5 Reference 1996 National Electrical Code NEC 3 4 15 16 in 1 2 1 2 Turn wingnut When a slight force is needed to turn spool tension is set Tools Needed 0 Install spool so welding wire feeds from bottom ...

Страница 14: ...n 102 mm Tighten Remove gun nozzle and contact tip Open pressure assembly Push wire thru guides into gun continue to hold wire Close and tighten pressure assembly and let go of wire ROG ZLUH WLJKWO WR NHHS LW IURP XQUDYHOLQJ WOOD Feed wire to check drive roll pressure Tighten knob enough to prevent slipping Cut off wire Close and latch door Press gun trigger until wire comes out of gun Reinstall c...

Страница 15: ...ickerthematerialthatcanbe welded Do not switch under load 2 Wire Speed Control Use control to select a wire feed speed As Voltage switch setting increases wire speed range also increases 3 Voltage Range Min Max Switch Place switch in desired position 4 Power Switch 2 1 3 4 ...

Страница 16: ...P DCEP DCEP DCEN DCEN DCEN DCEN DCEN DCEN DCEN DCEP 1 2 2 1 2 2 2 1 1 3 3 3 2 2 4 4 4 3or4 3or4 3 2 1 9 6 7 4 5 5 5 4 5 5 4 5 6 7 7 8 4 5 5 6 4 5 4 5 5 5 6 7 5 5 5 4 5 3 4 4 5 5 5 4 5 5 4 5 4 5 5 5 4 5 5 4 5 5 5 1 4 1 4 1 4 5 16 5 16 5 16 5 16 1 2 1 2 5 16 3 8 3 8 1 2 1 2 1 2 1 2 1 2 1 2 3 4 3 8 3 8 1 2 Brackets Axles A Frames Farm Equipment Frames Basketball RimsandBrackets 3 16 to1 4 4 TRI MIX 2...

Страница 17: ...ll Thedriverollconsistsoftwodiffer ent sized grooves The stamped markingsontheendsurfaceofthe driverollreferstothegrooveonthe opposite side of the drive roll The grooveclosesttothemotorshaftis the proper groove to thread see Section 3 8 NOTE when chang ing drive rolls make sure the woodruffkeyisonthemotorshaft and not in the old drive roll 4 Pressure Arm Tools Needed 1 2 4 3 030 Groove 024 Groove ...

Страница 18: ...contact tip see Section 5 3 Check for proper polarity connections see Section 3 2 Low weld output Connect unit to proper input voltage or check for low line voltage Place voltage switch in desired position see Section 4 1 Electrode wire feeding stops during welding Straighten gun cable and or replace damaged parts welding Adjust drive roll pressure see Section 3 8 Change to proper drive roll groov...

Страница 19: ...OM 194 034 Page 15 GND 34 50 60Hz S1 PL GS P C B Z SW S4 TP1 TP2 VR SR S3 S2 MAX MIN T1 93 3 9 ...

Страница 20: ...M 194 034 Page 16 DUGZDUH LV FRPPRQ DQG QRW DYDLODEOH XQOHVV OLVWHG 1 3 2 4 7 6 5 8 10 9 11 14 12 15 23 18 19 24 25 26 27 28 33 34 31 32 16 17 21 20 30 29 35 36 39 41 38 19 40 44 43 37 45 13 22 42 93 5 6 ...

Страница 21: ...12 2 2 20 S1 056067198 VP 0 0 15 1 1 21 S3 056067199 VP 0 0 16 1 1 22 156091023 VP 0 0 10 1 1 23 656110007 VN 0 0 11 1 1 24 Z 057098007 VP 0 4 1 24 Z 057098002 MU 0 3 1 25 156012092 VN 0 0 6 1 1 26 056054062 VP 0 0 17 2 2 27 156023159 ZH 0 0 11 2 2 28 656110008 VN 0 12 1 1 29 SR 056050132 VP 0 0 23 1 1 30 TP2 056159009 VP 0 0 21 1 1 31 T1 058021105 VN 1 1 31 T1 058021106 VO 1 1 32 TP1 056159006 MU...

Страница 22: ......

Страница 23: ... trade accessories These items are covered by the manufacturer s warranty if any 3 Equipment that has been modified by any party other than Hobart or equipment that has been improperly installed improperly operated or misused based upon industry standards or equipment which has not had reasonable and necessary maintenance or equipment which has been used for operation outside of the specifications...

Страница 24: ... 0RGHO 1DPH 6HULDO 6W OH 1XPEHU 3XUFKDVH DWH 0 LVWULEXWRU GGUHVV LW 6WDWH LS 3OHDVH FRPSOHWH DQG UHWDLQ ZLWK RXU SHUVRQDO UHFRUGV 2ZQHU V 5HFRUG ...