HOAC AUSTRIA
DV 20 Flight Manual
3.3.3. Fire
(a)
ENGINE FIRE DURING START ON THE GROUND
1.
2.
3.
4.
Fuel Shut-off Valve
Throttle
Master Switch (Battery)
Ignition Switch
5.
Evacuate Airplane immediately
(b)
ENGINE FIRE DURING FLIGHT
CLOSED
FULL
OFF
OFF
Emergency Procedures
1.
Airspeed
(VIAS)
70
kts. I
81
mph
1130
kmlh
2.
Flaps
TIO
3.
Fuel Shut-off Valve
CLOSED
4.
Throttle
FULL
5.
Electric Fuel Pump
OFF
6.
Cabin Heat
CLOSED
7.
Master Switch (Battery)
OFF
8.
Perform emergency landing with engine
off according to paragraph
3.3.2
(c)
ELECTRICAL FIRE INCLUDING SMOKE DURING FLIGHT
1.
2.
3.
4.
Master Switch (Battery)
Cabin Heat
Cabin Air
Fire Extinguisher
OFF
CLOSED
OPEN
use only if smoke development
continues.
CAUTION
While fire extinguisher is used, the cabin must be aerated.
Revision No.
Reference
Date
October
20, 1993
Page
3-9