129
Section VI.
Fault Diagnosis & Solutions
Section VI.
Fault Diagnosis & Solutions
HV590 is able to make full use of the device performance, while implementing effective
protection. You may encounter following fault tips during operation, please control the following
table analysis the possible causes, and rule out the fault.
6.1
Fault alarm and solutions
HV590 series can not only make full use of equipment performance but also implement
effective protection. HV590 series has 51 alarming information and protection function.Once
fault occurs, protection function acts,output stops, inverter fault relay contact starts,and fault
code is been displayed on the display panel. Before consulting the service department, the user
can perform self-check according to the prompts of this chapter, analyze the fault cause and find
out t solution. If the fault is caused by the reasons as described in the dotted frame, please
consult the agents or our company directly.
Among the 51 items of warning information
:
Fault no.22= Err22refers to hardware over-current or over-voltage signal.In most cases
hardware over-voltage fault led to fault no.22= Err22 alarming.
Fault name
Inverter unit protection
Panel display
Fault No.1= Err01
Fault investigation
1
、
Inverter output loop short circuit
2
、
Two long wiring between motor and inverter.
3
、
Module overheating
4
、
Inverter internal wiring loose
5
、
Main control board anomalies
6
、
Drive board anomalies
7
、
Inverter module anomalies
Fault
countermeasures
1
、
Eliminate external faults
2
、
Add reactor or output filter
3
、
Check air duct, fan and eliminate existing problems.
4
、
Insert all connecting wires
5
、
For technical support
Fault name
Acceleration over current
Panel display
Fault No.2= Err02
Fault investigation
1
、
Acceleration time too short
2
、
Improper manual torque boost or V/F curve
3
、
Low voltage
4
、
Inverter output loop grouded or short circuit
5
、
Vector control mode without parameter identification
6
、
Start the rotating motor
7
、
Sudden load add in acceleration process
8
、
Small type selection of inverter.
Fault
1
、
Increase acceleration time
Содержание HV590 Series