114
Section V.
Parameter Function Table
mode
determined through PE group.
User change parameter mode
Parameters which are different from factory default.
When existing display for PP.03, user could switch into different display mode through QUICK key.
Function parameter display mode as default.
Parameter display mode
Display
Function parameter mode-
FunC
User customization parameter
mode-USEt
User change parameter
mode-U--C
Display codes as below
:
HV590 series offers two groups of personalized parameter display mode
:
user customization
function mode, user change parameter mode.
In user customization parameter mode, sign u is added to the user customization function code as
default.
In user change parameter mode, sign c is added to the user customization function code as
default. E.g
:
P1.00 is displayed as cP1.00 .
PP.04
Function codes modification
attribute
Can be modified
0
0
☆
Can not be modified
1
This function is used to prevent misoperation of the function parameters.
PP.04=0
:
All the function codes can be modified.
PP.04=1
:
All the function codes can only be viewed, but not modified.
5.18
Torque control group
:
A0.00-A0.08
Code
Description/
Keyboard Display
Setting Range
Factory
Setting
Change
Limit
A0.00
Speed/ torque control mode
selection
Speed control
0
0
★
Torque control
1
A0.00 is used to select inverter control mode
:
speed control or torque control.
Multi-function digit DI terminal of HV590 is equipped with two functions relating torque control
:
Torque control banned(Function29), speed control/torque control switching (function 46). The two terminals
should be matched with A0.00 to realize switching between speed control and torque control.
A0.00 set the control mode when speed/torque control switching terminal invalid. If the speed/torque
control switching terminal is valid, control mode is equivalent to the inversion of A0.00 value.
When function 29 is valid, speed control mode is fixed for the inverter .
A0.01
Torque setup source selection
in torque control mode
Digital setup(A0.03)
0
0
★
AI1
1
AI2
2
AI3(Potentiometer)
3
PULSE
4
Commuication setup
5
Содержание HV590 Series
Страница 1: ...HV590 Series Frequency Inverter User Manual HNC Electric Limited ...
Страница 189: ......
Страница 192: ......