6.7. I/O Configuration
Figure 22. I/O configuration page
Enter the desired Size for the network input data and output data.
By default, the Communicator is set to use the same I/O sizes for both the EtherNet/IP and the Modbus TCP
networks.
To configure different sizes for the networks, deselect the Same I/O sizes for both networks checkbox.
Endian Swap
Big-endian
The big-endian format places the most significant byte of the data at the byte with the lowest memory address.
Little-endian
The little-endian format places the least significant byte of the data at the byte with the lowest memory address.
I/O Configuration
Anybus
®
Communicator
™
- EtherNet/IP
™
Adapter to Modbus TCP Server
SCM-1202-196 Version 1.0
Page 29 of 56