10. 

Electrical & Mechanical Features 

 
 

 

Enclosure 

Plastic, type ABS (UL 94 V-0) 
Net dimensions (d

x

w

x

h): 90x160x58 mm  

Recommended space for installation (d

x

w

x

h): 130x160x100mm 

Color: Light Grey. RAL 7035 

 

Battery 

Size: Coin 20mm x 3.2mm 
Capacity: 3V / 225mAh 
Type: Manganese Dioxide Lithium 

Mounting 

DIN rail EN60715 TH35. 

 

Console Port 

Mini Type-B USB 2.0 compliant 
1500VDC isolation 

Terminal Wiring 

(for power supply and 
 low-voltage signals) 

Per  terminal:  solid  wires  or  stranded  wires  (twisted  or  with 
ferrule) 

1 core: 0.5mm

2

… 2.5mm

2

 

2 cores: 0.5mm

2

… 1.5mm

2

 

3 cores: not permitted 

 

USB port 

Type-A USB 2.0 compliant 
Only  for  USB  flash  storage  device  (USB  pen 
drive) 
Power  consumption  limited  to  150mA  (HDD 
connection not allowed) 

Power 

1 x Plug-in screw terminal block (3 poles) 

Positive, Negative, Earth 
24VDC +/-10% Max.: 580mA 

 

Push Button 

Button A: Check section 8 
Button B: Check section 8 

Operation 
Temperature 

0°C to +60°C 

Ethernet 

1 x Ethernet 10/100 Mbps RJ45 
2 x Ethernet LED: port link and activity 

 

Operational 
Humidity 

5 to 95%, no condensation 

Port A 

1 x Serial EIA485 (Plug-in screw terminal block 2 poles) 

A, B 

1 x Plug-in screw terminal block green (2 poles) 

SGND (Reference ground or shield) 
1500VDC isolation from other ports 

 

Protection  

IP20 (IEC60529) 

LED 
Indicators 

8 x On board LED indicators 

1 x Error LED 
1 x Power LED 
2 x Port A TX/RX 

2 x Port B TX/RX 

1 x Button A indicator 
1 x Button B indicator 

Switch A  

(SWA)

 

1 x DIP-Switch for PORT A configuration: 

Position 1:  

ON:

 

120 Ω termination active 

Off:

 

120 Ω termination inactive 

Position 2-3: 

ON:

 Polarization active 

    Off:

 Polarization inactive

 

 

PORT B 

1 x EIA232 (SUB-D9 male connector) 

Reserved for future use 

1 x EIA485 port (Plug-in screw terminal block 3 poles) 

Reserved for future use 

 

 

 

Switch B  

(SWB)

 

1 x DIP-Switch for serial EIA485 configuration: 

Reserved for future use 

 

 

 

PORT C 

2 x Ethernet 10/100 Mbps RJ45 
4 x Ethernet LED: 2 x port link and 2 x activity 
 

 

 

 

Содержание Intesis BACnet

Страница 1: ...BACnet Server PROFINET IO Device USER MANUAL Issue date 05 2020 r1 0 ENGLISH...

Страница 2: ...s and are only intended to help improve understanding of the functionality and handling of the product In view of the wide range of possible applications of the product and because of the many variabl...

Страница 3: ...0 eng HMS Industrial Networks S L U All rights reserved This information is subject to change without notice URL https www intesis com 3 46 Gateway to connect BACnet MSTP or BACnet IP installations wi...

Страница 4: ...2 2 Analog Input Object Type 17 5 2 3 Analog Output Object Type 18 5 2 4 Analog Value Object Type 19 5 2 5 Binary Input Object Type 20 5 2 6 Binary Output Object Type 21 5 2 7 Binary Value Object Typ...

Страница 5: ...rial Networks S L U All rights reserved This information is subject to change without notice URL https www intesis com 5 46 9 2 5 Sending the configuration to Intesis 42 9 2 6 Diagnostic 42 Set up pro...

Страница 6: ...sed control systems or devices merging both systems into one The gateway acts as a BACnet IP Server or BACnet MSTP device in its BACnet interface allowing other BACnet devices to perform subscription...

Страница 7: ...ct has active subscriptions the new value will be sent to the subscripted BACnet device s From the BACnet system point of view after the start up process the gateway listens to any subscription COV re...

Страница 8: ...L BACnet Operator Workstation B OWS BACnet Building Controller B BC BACnet Advanced Application Controller B AAC BACnet Application Specific Controller B ASC BACnet Smart Sensor B SS BACnet Smart Actu...

Страница 9: ...t all routing configurations e g ARCNET Ethernet Ethernet MS TP etc Annex H BACnet Tunneling Router over IP BACnet IP Broadcast Management Device BBMD Does the BBMD support registrations by Foreign De...

Страница 10: ...DS COVP A Data Sharing COVP A SubscribeCOVProperty ConfirmedCOVNotification UnconfirmedCOVNotification DS COVP B Data Sharing COVP B SubscribeCOVProperty ConfirmedCOVNotification UnconfirmedCOVNotific...

Страница 11: ...ends Inernal B ReadRange T VMT E B Trending Viewing and Modifying Trends External B ReadRange T ATR A Trending Automated Trend Retrieval A ConfirmedEventNotification ReadRange T ATR B Trending Automat...

Страница 12: ...onfirmedTextMessage DM TS A Device Management TimeSynchronization A TimeSynchronization DM TS B Device Management TimeSynchronization B TimeSynchronization DM UTC A Device Management UTCTimeSynchroniz...

Страница 13: ...Access Services AddListElement RemoveListElement CreateObject DeleteObject ReadProperty ReadPropertyConditional ReadPropertyMultiple ReadRange WriteProperty WritePropertyMultiple Remote Device Managem...

Страница 14: ...orted are shown in the table below Object Type ID Supported Management Point Analog Input 0 Analog Output 1 Analog Value 2 Averaging 18 Binary Input 3 Binary Output 4 Binary Value 5 Calendar 6 Command...

Страница 15: ...ing O Protocol_Version Unsigned 1 R R Protocol_Revision Unsigned 14 R R Protocol_Services_ Supported BACnetServiceSupported Refer to section 4 Service Types R R Protocol_Object_Types_ Supported BACnet...

Страница 16: ...OV_ Subscriptions List of BACnetCOVSubscription List of BACnetCOVSubscription O R Slave_Proxy_Enable BACnetArray N of BOOLEAN O Manual_Slave_Address_ Binding List of BACnetAddressBinding O Auto_Slave_...

Страница 17: ...FALSE FALSE R R Event_State BACnetEventState STATE_NORMAL 0 R R Reliability BACnetReliability NO_FAULT_DETECTED 0 UNRELIABLE_OTHER 7 O R Out_Of_Service BOOLEAN FALSE R R Update_Interval Unsigned O Un...

Страница 18: ...0 R R Reliability BACnetReliability NO_FAULT_DETECTED 0 O R Out_Of_Service BOOLEAN FALSE R R Update_Interval Unsigned O Units BACnetEngineeringUnits Configurable through BACnet and Config Tool R R Min...

Страница 19: ...ALSE R R Event_State BACnetEventState STATE_NORMAL 0 R R Reliability BACnetReliability NO_FAULT_DETECTED 0 O R Out_Of_Service BOOLEAN FALSE R R Update_Interval Unsigned O Units BACnetEngineeringUnits...

Страница 20: ...RMAL 0 R R Reliability BACnetReliability NO_FAULT_DETECTED 0 UNRELIABLE_OTHER 7 O R Out_Of_Service BOOLEAN FALSE R R Polarity BACnetPolarity NORMAL 0 R R Inactive_Text CharacterString Configurable thr...

Страница 21: ...ce BOOLEAN FALSE R R Polarity BACnetPolarity NORMAL 0 R R Inactive_Text CharacterString Configurable through BACnet and Config Tool O R Active_Text CharacterString Configurable through BACnet and Conf...

Страница 22: ...ity BACnetReliability NO_FAULT_DETECTED 0 O R Out_Of_Service BOOLEAN FALSE R R Inactive_Text CharacterString Configurable through BACnet and Config Tool O R Active_Text CharacterString Configurable th...

Страница 23: ...String O Status_Flags BACnetStatusFlags FALSE FALSE TRUE FALSE FALSE R R Event_State BACnetEventState STATE_NORMAL 0 R R Reliability BACnetReliability NO_FAULT_DETECTED 0 UNRELIABLE_OTHER 7 O R Out_Of...

Страница 24: ...us_Flags BACnetStatusFlags FALSE FALSE FALSE FALSE R R Event_State BACnetEventState STATE_NORMAL 0 R R Reliability BACnetReliability NO_FAULT_DETECTED 0 O R Out_Of_Service BOOLEAN FALSE R R Number_Of_...

Страница 25: ...racterString O Status_Flags BACnetStatusFlags FALSE FALSE FALSE FALSE R R Event_State BACnetEventState STATE_NORMAL 0 R R Reliability BACnetReliability NO_FAULT_DETECTED 0 O R Out_Of_Service BOOLEAN F...

Страница 26: ...Object Type Property Identifier Property Datatype Value ASHRAE IBOX Object_Identifier BACnetObjectIdentifier Calendar 6 R R Object_Name CharacterString Configurable through BACnet and Config Tool R R...

Страница 27: ...ailySchedule R W Exception_Schedule BACnetARRAY N of BACnetSpecialEvent R W Schedule_Default Any R W List_Of_Object_Property_Refer ences BACnetLIST of BACnetDeviceObjectProper tyReference R R Priority...

Страница 28: ...ty Datatype Value ASHRAE IBOX Object_Identifier BACnetObjectIdentifier Notification_Class 15 R R Object_Name CharacterString Configurable through BACnet and Config Tool R R Object_Type BACnetObjectTyp...

Страница 29: ...g_Interval Unsigned O COV_Resubscription_Interval Unsigned O Client_COV_Increment BACnetClientCOV O Stop_When_Full BOOLEAN R R Buffer_Size Unsigned R R Log_Buffer List of BACnetLogRecord R R Record_Co...

Страница 30: ...ropertyReference O R Log_Interval Unsigned O COV_Resubscription_Interval Unsigned O Client_COV_Increment BACnetClientCOV O Stop_When_Full BOOLEAN R R Buffer_Size Unsigned R R Log_Buffer List of BACnet...

Страница 31: ...the network is automatically scanned for Intesis BACnet PROFINET modules The network can be rescanned at any time by cliking Scan To change the network settings of a BACnet PROFINET module double clic...

Страница 32: ...rt 80 The default web pages provide access to Network configuration parameters Network status information Access to the host application ADIs The network configuration page provides interfaces for cha...

Страница 33: ...n unicast packets broadcast and multicast Out Discards Outgoing packets discarded due to no available memory buffers Out Errors Transmission errors Media Counters Description Alignment Errors Frames r...

Страница 34: ...y Client MRC It also supports propagating link change to the Media Redundancy Master LED Indicators Network Status LED LED1 LED state Status Comments Off Offline No connection with IO controller Green...

Страница 35: ...sure traffic on the port used is allowed through all the LAN path check the gateway user manual for more information With factory settings after powering up the gateway DHCP will be enabled for 30 se...

Страница 36: ...ect a mini type B USB cable from your computer to the gateway to allow communication between the Configuration Software and the gateway Remember that Ethernet connection is also allowed Check the user...

Страница 37: ...tive and reachable from the network connection used by Intesis Check the Intesis Ethernet interface sending Pings to its IP address using a PC connected to the same Ethernet network Check as well with...

Страница 38: ...ice in a line topology either Port 1 or Port 2 can be used The cable to be used shall be a straight Ethernet UTP FTP CAT5 cable PROFINET interface contains a dual port Ethernet switch they both operat...

Страница 39: ...Tx Rx Expansion Module communication Off There is no activity on this port Tx Blinking green Every data packet sent to Expansion module it blinks Rx Blinking yellow Every data packet received from Ex...

Страница 40: ...to download the configuration tool USB Console cable to communicate with gateway Product documentation Intesis MAPS Configuration monitoring tool for Intesis BACnet series 9 2 1 Introduction Intesis M...

Страница 41: ...e subsets of information are shown in this window General Gateway general parameters BACnet Server BACnet interface configuration and PROFINET interface parameters Figure 9 2 Intesis MAPS configuratio...

Страница 42: ...e Intesis Communication Console window Intesis will reboot automatically once the new configuration is loaded Figure 9 4 Intesis MAPS Receive Send tab After any configuration change do not forget to s...

Страница 43: ...ng HMS Industrial Networks S L U All rights reserved This information is subject to change without notice URL https www intesis com 43 46 Figure 9 5 Diagnostic More information about the Diagnostic se...

Страница 44: ...nected to it we strongly recommend The use of DC power supplies floating or with the negative terminal connected to earth Never use a DC power supply with the positive terminal connected to earth 6 If...

Страница 45: ...3 poles Positive Negative Earth 24VDC 10 Max 580mA Push Button Button A Check section 8 Button B Check section 8 Operation Temperature 0 C to 60 C Ethernet 1 x Ethernet 10 100 Mbps RJ45 2 x Ethernet...

Страница 46: ...reserved This information is subject to change without notice URL https www intesis com 46 46 11 Dimensions Recommended available space for its installation into a cabinet wall or DIN rail mounting w...

Отзывы: