INSTALLATION INSTRUCTIONS

TRU-FIT 

DOOR & PANEL

STEP 2

Take the Wall Jamb (A) and line the center of it (indicated by die line) up with 

the center line of tub base found in Step 1.  The post should be sitting on the 

tub or shower base.  (See Figure 2)

STEP 3

Make sure that the Wall Jamb (A) is level before marking for holes. 

(See Figure 3)

FIGURE 2

FIGURE 3

STEP 1

Determine center line of your shower base by measuring the thickness of the 

base and use a pencil to mark the center.  Draw this line the entire length of the 

base. (See Figure 1)

FIGURE 1

STEP 4

Once the Wall Jamb (A) is level, use a pencil to mark the holes for drilling.  

Depending on the support behind the wall, Plastic Anchors (E) may or may 

not be required.  IF you are unsure, if unsure, use the Plastic Anchors (E) to be 

safe.  If using an anchor, use 1/4” drill bits to drill holes on the specified marks.  

If wooden support is present and no anchor is required, use 3/16” drill bits to 

drill holes on specified marks.  (See Figure 4)

NOTE: You may need several drill bits when drilling through certain types of 

tile or marble.  Keep your drill bit cool by spraying with water throughout the 

drilling process. 

FIGURE 4

V5_21_26

Figure 1

Figure 2

Figure 1

Figure 2

Содержание TRU-FIT

Страница 1: ...Angle Seal Optional 1 T CHGP972 Bulb Seal Optional 1 IMPORTANT NOTE Door should not be used for 72 hours in order to let silicone cure properly When ordering repair parts please provide the following information 1 Model Number 2 Part Number 3 Part Description 4 Finish Color Required Tools TWO PEOPLE Pencil Tape Measure Electric Drill Phillips Head Bit Scissors Level Flat Head Screwdriver Hammer Si...

Страница 2: ... damage or bodily injury caused by an improper installation Failure to follow these instructions guidelines and warnings will void your warranty and possibly cause anything form minor water damage to serious injury or death These units have been tested under extreme usage condi tions and have not failed WHEN PROPERLY INSTALLED WHEN YOU START YOUR INSTALLATION Carefully remove all the enclosure par...

Страница 3: ...ength of the base See Figure 1 FIGURE 1 STEP 4 Once the Wall Jamb A is level use a pencil to mark the holes for drilling Depending on the support behind the wall Plastic Anchors E may or may not be required IF you are unsure if unsure use the Plastic Anchors E to be safe If using an anchor use 1 4 drill bits to drill holes on the specified marks If wooden support is present and no anchor is requir...

Страница 4: ...ee Figure 7 Use your masking tape to secure the Curb Channel D to your base DO NOT SUE SILICONE OR SCREWS YET ONLY TAPE See Figure 7 STEP 8 Place Wall Channel C on top of Curb Channel D and centerline up wall Once the Wall Channel C is plumb use a pencil to mark the holes for drilling Depending on the support behind the wall Plastic Anchors for Channels J may or may not be required If you are unsu...

Страница 5: ...l pieces of tape inside and outside secure Glass Panel P to wall for the time being See Figure 11A STEP 9 Put a small amount of silicone in each hole drilled Place Plastic An chors for Channels J if needed in holes gently tap with hammer until anchor is flush It might be necessary to use a razor knife to cut the lip of the anchor off so it is completely flush with the wall Be sure not to hit the t...

Страница 6: ...ace while one person steadies the door the other can adjust both pieces of glass so that you have about 1 8 gap between glass panels See Figure 14 1 8 is recommended to reduce leakage but can be larger if desired It is ideal to adjust a little in both door and panel instead of pulling all the adjustment out of one or the other depending on your size you might have to fully adjust both to ensure pr...

Страница 7: ... have an 1 8 gap between door glass and panel glass Make any necessary changes to the Glass Panel P See Figure 17 FIGURE 17 STEP 18 With the Glass Panel P in place measure from wall to edge of panel glass This measurement will be the length you need to cut your Curb Channel D See Figure 18 FIGURE 18 STEP 19 Using a pencil mark your measurement on your Curb Channel D Proceed to cut the Curb Channel...

Страница 8: ... 21 Place two stacks of three Glass Blocks Q inside the Curb Channel D per Figure 20A NOTE DO NOT SET ON SCREW HEADS These glass blocks will be used not only to cushion and protect panel from screw heads but to also adjust the height of the panel to match the door You can remove glass blocks to lower panel cut glass blocks in half and stack more than three to raise the panel See Figure 21A When re...

Страница 9: ...icone FIGURE 24 STEP 24 We have supplied two extra 8 x 3 4 SelfTapping Screws L WE RECOMMEND PUTTING THESE ON THE OUTSIDE OF THE UNIT FOR EXTRA SUPPORT These are not necessary but highly suggested to eliminate any movement during usage Using a 1 8 drill bit drill two pilot holes through both the Hinge Jamb B and the Wall Jamb A centered vertically with the Door Hinges E See Figure 24 FIGURE 25 STE...

Страница 10: ...egs going in Hinge Jamb B See Figure 26A and mark for cutting See Figure 26B MAKE SURE CAP IS TOUCHING BACK WALL BEFORE MARKING Cut cap on mark using scissors See Figure 26C Place drop of silicone on the outside of both legs See Figure 26D Turn the Adjustable Post Cap N around and install with the legs going into the Wall Jamb A See Figure 26E FIGURE 26A FIGURE 26B FIGURE 26C FIGURE 26D FIGURE 26E...

Страница 11: ...lass TRU FIT DOOR PANEL FIGURE 28A STEP 28 Place handle through holes in the Door Glass O Make sure that the clear washers are touching the glass Gently tighten handle screws so that handle is snug on glass DO NOT OVER TIGHTENTHE SCREWS with the allen wrenches supplied with the pull Over tightening can crack the washers See Figure 28A Place other side of handle on studs See Figure 28B with set scr...

Страница 12: ...s of glass You will need to cut into 3 pieces that will fit the small areas from top hinge to top of door bottom hinge to bottom of door and the large area between hinges Remove red cover ing to expose adhesive and apply to edge of glass See Figure 29B ZV Angle Seal M This is to be placed on handle side of door DIRECTLY to the Panel Glass P make sure glass is clean and dry before application See F...

Страница 13: ...ESHOOTING To make a claim under the provisions of this warranty please contact your local HMI Shower Enclosure dealer They should be able to solve any problem you might have If your dealer cannot solve your problem they will contact your local HMI Shower Enclosure distribution center If you are unable to obtain warranty service through your local HMI Shower Enclosure distribution center you can co...

Отзывы: