REGISTRATION INSTRUCTIONS
Prior to operation of the DX200 system, each Belt-pac must be registered for use with a specific
base station. The base station will then recognize all registered Belt-pacs when their power is
on, differentiating between them and interfering transmissions from other electronic equipment
operating on similar frequencies. If a Belt-pac is added or replaced later, the new one must be
registered. When a Belt-pac is replaced, the old one remains in memory. A maximum of 15 Belt-
pacs can be registered to a single base station. If the maximum number of 15 (in memory) is
exceeded, an
F
will appear in the
REGISTRATION STATUS
display on the base station and you
will hear “
Registration failed
” in the headset. If this happens, refer to the last section on the
back of this sheet.
Register each Belt-pac as follows:
NOTE:
Belt-pacs must be within 6 feet (1.83 meters) of the base station while being registered.
Be certain all Belt-pacs to be registered are powered off and the base station power is on.
Other Belt-pacs can be on or off.
Press the
REGISTER BELT-PAC
button shown in Figure 1.
⎯
After you press the
REGISTER BELT-PAC
button, the
REGISTRATION STATUS
display will
show a small “o” for open.
Figure 1. Registration buttons and indicator on left front panel of base station
HM ELECTRONICS, INC.
14110 Stowe Drive, Poway, CA 92064 USA
•
Phone: 1-800-848-4468 Fax: (858) 552-0172
HME# 400544
Rev— 3/2/04
NOTE:
To press the
RESET
button,
insert a small
paper clip or
similar object
into the
RESET
hole.