HM Digital PS-202 Скачать руководство пользователя страница 1

USER’S GUIDE

PANEL CUT

-OUT DIA

GR

A

M

M

H

D

I

G

I

T A

L

®

PS-202

PANEL MOUNT DUAL DISPLAY

TDS CONTROLLER 

1. Using a knife, cut the diagram out (cut on the outer part of the line).
2. Align the cut-out to your panel and draw cut marks.
3. Cut the hole in the panel to the precise dimensions of the cut-out:
     3-9/16 in. x -3-9/16 in. (90 mm x 90 mm)

 

--> 

See the installation section for complete instructions.

CONTACT DIAGRAM

9

/

16 

in. (90 mm)

 

9

/

16 

in. (90 mm)

 

  AC

WHITE

RED

BLACK

LINE 1 SENSOR (IN)

110-220V

LINE 2 RELAY (SWITCH)

N.C.

N.O.

WHITE

RED

BLACK

LINE 2 SENSOR (OUT)

8

9

10

11

12

13

14

15

1

2

3

4

5

6

7

16

17

18

19

20

21

22

23

LINE 1 RELAY (SWITCH)

N.C.

N.O.

HM PS

-202

Содержание PS-202

Страница 1: ...marks 3 Cut the hole in the panel to the precise dimensions of the cut out 3 9 16 in x 3 9 16 in 90 mm x 90 mm See the installation section for complete instructions CONTACT DIAGRAM 3 9 16 in 90 mm 3 9 16 in 90 mm AC WHITE RED BLACK LINE 1 SENSOR IN 110 220V LINE 2 RELAY SWITCH N C N O WHITE RED BLACK LINE 2 SENSOR OUT 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 16 17 18 19 20 21 22 23 LINE 1 RELAY SWITCH...

Страница 2: ...t Relay dual isolated 2A Max 220V resistive load 100 000 strokes Relay Control The unit will open or close a circuit via dry contacts when the ppm level of either sensor reaches or exceeds the control setting simple switch It can be used to control a pump solenoid valve or other device Each relay control is independent Relay Voltage 5V the connected device needs its own power source Alarm Optional...

Страница 3: ...the bottom position to disable the alarm for Line 1 and slide dipswitch 2 to the bottom position to disable the alarm for Line 2 16 Plug the power cord into an electrical outlet The controller does not have a power switch and will automatically power on when the power is connected WARRANTY ONE YEAR LIMITED WARRANTY The PS 202 including the controller and both sensors is warranted by HM Digital Inc...

Страница 4: ...s will accomodate for the lack of flowing water which the controller is programmed for For example if the calibration solution is 342 ppm adjust the screw until it reads 352 ppm If you are calibrating to a flowing solution calibrate to the level of the solution 7 Gently release the screwdriver from the trimmer pot 8 Your controller is now calibrated There is no need to do anything else Your contro...

Отзывы: