HQ – 005. ELECTRIC ACTUATORS 

QUARTER-TURN ELECTRIC ACTUATORS

 

 

HQ-005 Electric Actuators 
Version 

– Ver. 1 

Revision 

– Rev. 3 

Document No. HKQI-611

 

Actuated Solutions Ltd

 

 

Unit 9, Evans Place, Durban Road, Bognor Regis, West Sussex, PO22 9RY   

Tel: 01243 827469 

Fax: 01243 829418 

Email: [email protected] 

Website: www.actuated-solutions.co.uk 

 

Small & Compact Design 

 

High corrosion resistance 

 

Beacon indicator with LED lamps 

 

IP67 Weatherproof Aluminium housing 

 

Multi-voltage Power Supply 

 

Long life cycle 

Содержание HQ-005

Страница 1: ...t No HKQI 611 Actuated Solutions Ltd Unit 9 Evans Place Durban Road Bognor Regis West Sussex PO22 9RY Tel 01243 827469 Fax 01243 829418 Email sales actuated solutions co uk Website www actuated solutions co uk Small Compact Design High corrosion resistance Beacon indicator with LED lamps IP67 Weatherproof Aluminium housing Multi voltage Power Supply Long life cycle ...

Страница 2: ...d Technical Data 3 3 1 3 HQ 005 Optional Technical Data Optional 3 3 1 4 Duty Cycle 1 3 3 1 5 Torque Control 4 3 1 6 Manual Override 4 3 1 7 Lubrication 4 3 2 External Parts for Standard Models 5 3 3 Internal Parts for Standard Models 5 4 INSTALLATION 6 4 1 Pre installation for using in General Service 6 4 2 Actuator Mounting 6 4 2 1 Actuator Mounting Base Details 7 4 3 Limit Switch Setting 8 5 MA...

Страница 3: ...he user must take to reduce the risk of personal injury and damage to the equipment The user s must read these instructions before the installation operation or maintenance of HQ 005 electric actuators DANGER Refers to personal safety and alerts the user to danger or harm The hazard or unsafe practice will result in severe injury or death WARNING Refers to personal safety Alerts the user to potent...

Страница 4: ...eet Remove the packing wrap or wooden box carefully Inspect the product for any physical damage that may have occurred during shipment Check the product specification with product ordered If a wrong product has been shipped immediately report to our coordinator 2 3 Storage Actuators must be stored in a clean cool and dry area The unit should be stored with the cover installed and the conduit openi...

Страница 5: ...V AC 1 Ph 60 50Hz 24 V DC AC Duty Type S4 70 S2 30min IEC 60034 Motor BLDC motor Limit Switches 2 x open close SPDT 250V AC 5A rating Auxiliary Limit Switches 2 x open close SPDT 250V AC 5A rating Indicator Continuous position indicator full position LED lamp Manual Override Manual Handwheel Lubrication Grease moly EP Ambient Temperature 20 80 External Coating Dry powder polyester TS Torque overlo...

Страница 6: ...Override Caution Ensure power is isolated before the manual override is engaged The manual override lever must be dis engaged before power is applied to the actuator Failure to do so will end in motor burnout Gently oscillate the handwheel while engaging disengaging the manual override lever The lever in vertical position Engaged The lever in horizontal position Dis engaged 3 1 7 Lubrication HQ 00...

Страница 7: ...ouble square 14mm 4 Mounting base F03 F04 F05 F07 5 Manual lever 6 Name Plate 7 Captive cover bolt 8 Beacon Indicator 9 Fully closed LED lamp red color 10 Manual hand wheel 11 Fully open LED lamp green color Internal Parts HQ 005 1 Manual push shaft 2 Indicator 3 PCB 4 Auxiliary Open Switch White 5 Closed limit switch Green 6 Open limit switch Red 7 Auxiliary Closed Switch Black 8 Fully closed LED...

Страница 8: ...ate for the intended application 4 2 Actuator Mounting Note Prior to mounting the actuator must be checked for any damage Damaged parts must be replaced by original spare parts Mounting is most easily done with the valve shaft pointing vertically upward But mounting is also possible in any other position the actuator may be mounted in any position WARNING Read this installation operation and maint...

Страница 9: ...ure both the actuator and valve are fully closed DANGER HAZARDOUS VOLTAGE Make sure all incoming power is disconnected before performing the mounting Direct Mounting ISO Standard Actuator Fully Closed Valve Fully Closed Bracket Mounting Actuator Mounting Base F03 F04 F05 F07 F04 Bolt Circles 45 F03 F05 F07 Bolt Circles Star Adapter 14mm 11mm 14mm 9mm ...

Страница 10: ... switch lever until the switch clicks Tighten the set screw with the Allen key Manually rotate the hand wheel of the actuator to opened position Using the Allen key loosen the set screw in the OPEN limit switch cam Rotate the OPEN cam towards CCW limit switch lever until the switch clicks see Figure below Tighten the set screw with the Allen key DANGER HAZARDOUS VOLTAGE Make sure all incoming powe...

Страница 11: ...ensation Check the enclosure of O ring seals and verify that the O rings are not pinched between flange Verify the declutch mechanism Visually inspect the open close cycle Inspect the identification labels for wear and replace it if necessary 5 2 Tools Metric Allen Key Hex Wrench 1 Screw Driver 1 Metric Spanner 1 Wrench 200mm 1 Wrench 300mm 1 Wire Stripper Long Nose 1 Multi meter AC Dc Resistance ...

Страница 12: ...ockwise rotation to open Check for any corrosion and condensation that any of the electrical or mechanical devices have not been contaminated Verify that coupler bracket is correctly installed and is not causing any binding Actuator runs erratically Check the ambient temperature Verify that the duty cycle has not been exceeded Check the position of manual override lever Symptom Probable Cause Corr...

Страница 13: ...onal Equipment s 1 Potentiometer Current Position Transmitter Check the resistance value Check potentiometer gear for jamming Check ZERO and SPAN calibration Check the board for any damage 2 PCU Positioner card Verify the input signal Check the configuration of the dip switches Check the board for any damage ...

Страница 14: ...l HQ 005 Electric Actuator Document No HKQI 611 12 P a g e 7 DIMENSIONS Note For more information regarding this product please contact the manufacturer or your supplier for more details Please refer to the website for the latest wiring diagrams ...