HJM_RCL_ENG_Rev.1_30-11-2017
Made in Spain
5
/
21
Allow for a minimum distance of 1 m, from the front of the unit to any obstacles
(furniture, walls, curtains, for example) that could hinder its operation.
Also keep a minimum distance of 15 cm between the appliance and the side
walls and any other obstacles (walls, for example) that may affect its function.
Also keep a minimum distance of 35 cm on top the appliance free of obstacles
and a minimum distance of 15 cm from the floor.
WARNING: If this appliance is installed in a bathroom, it must be installed only
within Zones 2 or Outside Zones (Zone3), according BS 7671 Requirements
for Electrical Installations, Section 701. The installation of this appliance within
Zones 0 or 1 of a bathroom is totally prohibited. The figure 2 bellow is only for
information purposes, we suggest you contact a professional electrician.
- Minimum Distances -
Fig.1
Zone 1: Appliances supplied to Safety Extra Low Voltage (SELV).
Zone 2: Electrical Appliances Class II – IP X4
Zone 3: Electrical Appliances protected by RCD 30mA
Fig.2
WALL-MOUNTING
The appliance is equipped with the following:
- 2 radiator's suspension supports..
INSTALLATION INSTRUCTIONS
1. Place the template against the wall where you will place the radiator and mark
the location of the holes.
2. Drill the holes and insert the plugs to fix the supports to the wall.
3. Place the radiator in the low part of the supports, doing that two of the fins slip
along the grooves.
4. Hang the radiator in the supports you have already fixed to the wall.
5. Screw up the supports to secure the radiator.