EHC-NERIS_ENG-Rev.0-23-09-2021
5
/
19
•
Allow for a minimum distance of 1m from the front of the unit to any
obstacles that could hinder its operation.
•
Keep a minimum distance of 15 cm between the appliance and the side
walls and any other obstacles (walls, for example) that may affect its
function.
•
WARNING: When this appliance is installed in a bathroom, it must be
installed within Zone 2 in accordance with BS7671. Requirements for
Electrical Installations, Section 701. The installation of this appliance
within Zones 0 or 1 of a bathroom is totally prohibited. Figure 2 bellow is
only for information purposes, we suggest you contact a professional
electrician for installation of your heater.
Zone 1: Appliances supplied to Safety Extra Low Voltage (SELV).
Zone 2: Electrical Appliances Class II – IP X24
Fig.2
WALL-MOUNTING
The towel radiator is equipped with the following components:
- 4 towel radiator suspension brackets as shown in (Fig 1).
Fig. 1
1. Cut and place the template on the wall at a minimum recommended
height of 600mm. (This is for ease of controller use) The heater can
be mounted lower if this is your preference however care should be
taken where young children are present.