68
Faults
Assembly Instructions
Linear Axes HM-S and HT-S
HMS_HTS-01-0-EN-1905-MA
8.2 Motor malfunctions
For interpretation of faults and information on how to remedy them, see the motor’s operating instructions.
8.3 Faults during operation with drive amplifier
For interpretation of faults and information on how to remedy them, see the drive’s operating instructions.
Fault
Possible cause
Remedy
Table of linear module HM-S and linear table HT-S malfunctions (continuation)
Motor load rising,
controller shut-
ting down owing to
overload
Tensions in the system or lack of
lubrication
Install axis free of tension; check flatness of bearing
surface and attached load. Relubricate axis
Heavy contamination on the axis and
internal guiding mechanisms
Clean axis, reinstate free movement of guiding and
drive elements