10

 

Declaration of Conformity 

 
We declare under sole responsibility that the product 
 

Device: 

High Voltage Amplifiers

 

 
Model: 

HA61-3B30 

 
is  in accordance with the following European directives: 
 
Low Voltage Directive 

2014/35/EU  

EMC Directive 

2014/30/EU  

 
and comply with the following European standards: 
 
EN 61010-1:2010 

Safety requirements for electrical equipment for 
measurement, control, and laboratory use -  
Part 1: General requirements 

 
 

 

EN 61326-1:2013 

Electrical equipment for measurement, control and 
laboratory use -  
EMC requirements - Part 1: General requirements 
 
Classification: Group 1, Class B 

 

 

 
 
 
Manufacturer: 
 

hivolt.de GmbH & Co. KG 

Oehleckerring 40 
D-22419 Hamburg 
 
2020-06-21 
 
 
 
 
 
 
 
 
Wulf Müller 
Managing Director 

Содержание HA61-3B30

Страница 1: ...1 hivolt de GmbH Co KG Oehleckerring 40 D 22419 Hamburg Germany 49 40 537122 0 49 40 537122 99 info hivolt de www hivolt de HA61 3B30 High Voltage Amplifier 3000V Operating Manual...

Страница 2: ...nitor 15 4 2 Ambient Conditions 15 4 3 Mechanical Specifications 15 5 OPERATION 16 5 1 Initial Check 16 5 2 Warning Notices 16 5 3 Temperature Compensation 16 5 4 Installation 17 5 5 Mains Connection...

Страница 3: ...49 40 537122 0 49 40 537122 99 info hivolt de www hivolt de 6 9 Status Word 3 26 7 SIGNAL GENERATOR 27 8 SCPI PROTOCOL 27 9 OPERATION MAINTENANCE 27 9 1 Troubleshooting 27 9 2 Maintenance 28 9 3 Clea...

Страница 4: ...t must be secured against unintentional or accidental operation The safety ground must always be connected The ground screw on the rear panel must be connected to the grounding point of the setup and...

Страница 5: ...u keiner Gef hrdung kommen kann Die Hochspannung f hrenden Bereiche m ssen vorschriftengerecht abgesperrt oder anderweitig gesichert sein Sollte der Verdacht bestehen dass das Ger t besch digt ist ode...

Страница 6: ...put and one 24V compatible INH input are provided to quickly switch the output on and off The maximum output current can be limited to programmable values and programmable behavior When the output cur...

Страница 7: ...noise as well as fully arbitrary wave shapes Parameters like waveform amplitude frequency duty cycle rise fall time offset DC value current limit and further functional parameters are controllable vi...

Страница 8: ...es The monitor outputs are buffered output impedance 1k and short circuit proof They are able to drive capacitive loads coaxial cables but are not designed to drive cables with a low impedance termina...

Страница 9: ...These parameters can be set independently Limiting the instantaneous value of the output current will not result in a shutdown condition but it has an influence on the dynamic behavior of the output...

Страница 10: ...r then with a slight overshoot Large capacitive loads driven by high frequency signals may result in a DC offset superimposed on the output voltage This occurs if the final value of the desired output...

Страница 11: ...via the 24V control signals INTERLOCK ON and INTERLOCK OFF on the interlock interface or via software command SHS The high voltage can only be switched on when the Interlock shutdown state is cleared...

Страница 12: ...on as the interlock circuits are closed IL1 and IL2 at H level This operating mode involves a safety risk STS SDR Shutdown Status Shutdown Reset When an error occurs interlock overload overtemperature...

Страница 13: ...olt de Operation without using ON OFF control SDR STS OFF GND INH 2 1 2 1 EMERGENCY STOP X2 INTERLOCK 1 2 3 4 5 6 7 8 9 10 SDR 24V_IL GND STS IL1 ON IL2 INH STS_HV STS_HV The device must be disconnect...

Страница 14: ...nge 3000V 3000V Load current range static 30mA 30mA Load current range dynamic t 0 6s 50mA 50mA Power bandwidth CL 50pF VO 6000VPP THD 1 DC 15kHz DC 1 6kHz Bandwidth CL 50pF VI 2VPP 3dB DC 50kHz DC 16...

Страница 15: ...re Operation Storage and Transportation 0 25 40 70 C C Relative humidity Operation Storage and Transportation Not condensing 5 5 80 95 Depending on the ambient temperature modulation amplitude and loa...

Страница 16: ...e the device is put into operation The test setup must be checked each time before the device is put into operation to ensure that it is not potentially dangerous It should be checked that the high vo...

Страница 17: ...se check the available mains voltage The device may be damaged if operated with the wrong mains voltage 5 6 Grounding The M4 grounding nut and screw on the rear panel of the device must be connected t...

Страница 18: ...l light up 10 Push the ON push button Warning Now High Voltage can be present at the output connector 11 The HV OK LED will light up the OFF push button and the HV OFF palm button will light up 12 Pus...

Страница 19: ...load the drivers from https www ftdichip com Drivers VCP htm and install then manually In the Device Manager entries are displayed under USB Controller USB Serial Converter and under Ports COM LPT USB...

Страница 20: ...m pars cr lf Response err id pars cr lf Start character id 1AN Sequence id an alphanumeric character not the id is returned with the response for identification of the command sequence com 3AN Command...

Страница 21: ...Read aux values 1 Supply Voltages P24V mV actual value of 24V supply P15V mV actual value of 15V supply N15V mV actual value of 15V supply P48V_HV mV actual value of 48V supply HV P15V_HV mV actual va...

Страница 22: ...IHVNAV_AVG A positive HV supply output current averaged value RHM 0 VO_NOM 1 5 VO_NOM 1 5 0 0 IO_M IO_M 0 Read high voltage source momentary values VHVPAV V positive HV supply voltage actual value VHV...

Страница 23: ...f the PID I controller component SCP 1 1000 X Set PID controller P component Param PIDP_SP non dimensional Default 10 SCR SRL_MIN SRL_MAX 0 1 X Set slew rate limiter rate and enable Param SRLR_SP V s...

Страница 24: ...IO_M mA 150 30 75 75 150 IO measurement range SRL_MIN V s 1 S R Limiter min setting SRL_MAX V s 400 30 S R Limiter max setting IO_LIM_MAX mA 60 30 50 50 100 PA max current limit IHVP_LIM_MAX mA 30 10...

Страница 25: ...W_OTP_SDN_HV 4 1 STW_OVP_SDN_HV X 1 OVP Shutdown latched HV OVP_SDN_HV 5 2 STW_OSC_SDN X 1 Oscillation Detect Shutdown STW_OSC_DET 6 4 STW_PWFAIL_SDN X 1 Supply Voltages Error Shutdown STW_PWFAIL_HV S...

Страница 26: ...HV I48V Shutdown latched HV 8 1 9 2 STW_OTP_SDN_PA X 1 Overtemperature PA OTP_SDN_PA 10 4 STW_OTP_SDN_HV X 1 HV OTP Shutdown latched HV OTP_SDN_HV 11 8 12 1 STW_OSC_DET X 1 Oscillation Detected OSC_D...

Страница 27: ...ot attempt to locate any faults within the device This can be dangerous to life due to the high voltage used in the device In such a case please return the device to the manufacturer after consultatio...

Страница 28: ...ated dust has to be removed by blowing out the unit cautiously The manufacturer specified lifetime of the fans is 50000h After about 6 years of continuous operation the fans might be replaced Type SUN...

Страница 29: ...SB port to the USB COM interface on HA61 2 open the terminal program and connect to the COM port as shown in the Windows device manager configuration 115 200 kBd no parity bit 8 data bits 1 stop bit 1...

Страница 30: ...on the terminal program re connect to the appropriate COM port 14 enter command RID to check the connection and see the new software version number 15 start the update of the HV generator software by...

Страница 31: ...ves Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU and comply with the following European standards EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and...

Отзывы: