HTM(HPV)-20N Series
HITROL CO., LTD.
6
The HTM(HPV)-20N_Series is installed on the top or the side of a container and silo to
detect the upper or the lower limit, respectively. The level switch can be installed on any
material, so it is applicable to ferrous or nonferrous tanks and silos.
When installing this product, consider the following.
Installation on Side (Horizontal)
■
A-Type or B-Type can be installed on the side of a tank. A screw-socket shape under
24mm shall be used for installing the A-Type on the side. Otherwise, dust or foreign
matter may enter, resulting in a malfunction. The extended B-Type supports the screw
and the flange.
■
When side installation, it shall be installed slopingly (more than 15°) with a direction of
wider side of tuning fork vertically to avoid build-up of the medium on the tuning
fork. (Refer to Fig. 1)
■
Sensor shall be installed at the place far from inlet of the tank and protector shall be
installed in order to protect the sensor from damage by falling medium if it is installed
at the inlet. (Refer to Fig. 1)
When installing the product, install it using a tool that fits the hexagon connector of
the screw.
Max. Length shall be 500mm or less for a side installation.
Ex-proof Version
Attachment
& Precautions
HPV-20N(H)-A
HPV-20N(H)-B
HPV-20N(H)-B
<Screw Type>
<Flange Type>